In-situ test and data analysis of frost-heave force
of Kunlun Mountain Tunnel |
| |
Authors: | ZHANG Jun-ru QIU Wen-ge |
| |
Institution: | School of Civil Engineering, Southwest Jiaotong University, Chengdu 610031, China |
| |
Abstract: | Frost-heave force is one of the main reasons to create disease of supporting structure in frozen soil tunnel; in order to master the distribution shape and the regularity as change as temperature of frost-heave force of Kunlun Mountain Tunnel in permefrast area, in-situ test was carried out. The research results show: by far, the whole supporting structure of Kunlun Mountain Tunnel was safe and reliable; frost-heave force was as change as temperature and season; the change would go to stabilize after 2004, the Max testing frost-heave force was 0.3 MPa, it located in the arch invert between surrounding rock and preliminary bracing; the frost-heave force between preliminary bracing and lining was very small; the supporting strength of lining would consider weaken properly; the frost-heave force envelope curve was plotted by using influence line theory; and it offers a proper and effective method to determine the most disadvantage load which act on the supporting structure. |
| |
Keywords: | Kunlun Mountain Tunnel frost-heave force in-situ test envelope curve |
|
| 点击此处可从《岩土力学》浏览原始摘要信息 |
| 点击此处可从《岩土力学》下载免费的PDF全文 |
|