玄武岩全岩元素含量快速、准确分析新技术:双铱带高温炉与LA-ICP-MS联用法
引用本文:朱律运,刘勇胜,胡兆初,高山,王晓红,田滔.玄武岩全岩元素含量快速、准确分析新技术:双铱带高温炉与LA-ICP-MS联用法[J].地球化学,2011(5):407-417.
作者姓名:朱律运  刘勇胜  胡兆初  高山  王晓红  田滔
作者单位:中国地质大学(武汉)地质过程与矿产资源国家重点实验室;中国地质大学(武汉)地球科学学院
基金项目:国家自然科学基金(90914007,40821061);地质过程与矿产资源国家重点实验室科技部专项经费(MSFGPMR200904);中央高校基本科研业务费专项资金
摘    要:全岩样品主元素和微量元素的准确测试是地球科学研究的重要手段和依据.传统溶液进样ICP-MS元素测试方法制样和测试所需周期较长(两周以上).相对溶液进样法而言,激光剥蚀系统与ICP-MS联用测试全岩粉末熔融玻璃的方法可以大大地提高测试效率.在前人研究基础上,针对前人熔融制样中Pb、Zn元素的严重丢失问题,研究了Pb、Zn...

关 键 词:LA-ICP-MS  全岩测试  无助熔剂熔融  双铱带高温炉

Quick and accurate LA-ICP-MS analyses of major and trace elements in basalt,coupled with glass fusion method by double iridium strip heater
ZHU Lü-yun,LIU Yong-sheng,HU Zhao-chu,GAO Shan,WANG Xiao-hong,and TIAN Tao.Quick and accurate LA-ICP-MS analyses of major and trace elements in basalt,coupled with glass fusion method by double iridium strip heater[J].Geochimica,2011(5):407-417.
Authors:ZHU Lü-yun  LIU Yong-sheng  HU Zhao-chu  GAO Shan  WANG Xiao-hong  and TIAN Tao
Institution:1.State Key Laboratory of Geological Processes and Mineral Resources,China University of Geosciences,Wuhan 430074,China;2.Faculty of Earth Sciences,China University of Geosciences,Wuhan 430074,China
Abstract:Quick and accurate analyses of major and trace elements in rock samples are important for geochemical research.Major disadvantage of the traditional solution-ICP-MS analysis is time consuming,which takes about two weeks to prepare and determine a sample.In order to increase analytical efficiency,some researchers tried to directly analyze fused glass of rock powder by LA-ICP-MS.Based on the previous researches,we propose a modified method to fuse the geological sample without flux by double iridium strip heater,which effectively suppresses the volatilization of Pb and Zn,a major disadvantage of traditional fusing method.Applying multiple reference material(BIR-1G,BCR-2G and BHVO-2G) calibration combined with ablation yield correction,the results of LA-ICP-MS analyses on the fused glasses prepared at 1400 ℃ for 80 s,show that measured values of most major and trace elements agree with the preferred values within 5%–10%.Comparing to the traditional method of solution-ICP-MS analysis,this work provides a much more rapid(less than 15 min) way to accurately determine major and trace elements for basalts.
Keywords:LA-ICP-MS  bulk analysis  flux-free fusion  double iridium strip heater