刚性桩复合地基侧向土压力试验研究
引用本文:佟建兴,闫明礼,王明山,孙训海,杨新辉.刚性桩复合地基侧向土压力试验研究[J].岩土力学,2014,35(6):1572-1578.
作者姓名:佟建兴  闫明礼  王明山  孙训海  杨新辉
作者单位:中国建筑科学研究院地基基础研究所,北京 100013
摘    要:通过室内模型试验,实测得到试验条件下,天然地基和刚性桩复合地基作用在不允许有位移的刚性挡土墙上的侧向土压力;通过与天然地基对比分析,获得了刚性桩复合地基的侧向土压力特性及分布规律。结果表明,刚性桩复合地基中桩的参与(包括桩的荷载深层传递作用、桩负摩擦区的影响和桩体对桩间土水平附加应力的“遮拦”作用等)使复合地基侧向土压力大小和分布规律明显区别于天然地基;在给定荷载水平下,刚性桩复合地基的侧向土压力值低于天然地基,侧向土压力影响范围较天然地基作用位置更深;在试验条件下,刚性挡土墙距离建筑物0.35~1.4 m范围内,当荷载水平达到地基承载力特征值时,刚性桩复合地基作用在刚性挡土墙上的总土压力和附加土压力约为天然地基的43.3%~80.1%和15.9%~59.8%。

关 键 词:刚性桩复合地基  侧向土压力  超载  模型试验  
收稿时间:2013-03-18

Experimental study of lateral earth pressure of rigid pile composite foundation
TONG Jian-xing,YAN Ming-li,WANG Ming-shan,SUN Xun-hai,YANG Xin-hui.Experimental study of lateral earth pressure of rigid pile composite foundation[J].Rock and Soil Mechanics,2014,35(6):1572-1578.
Authors:TONG Jian-xing  YAN Ming-li  WANG Ming-shan  SUN Xun-hai  YANG Xin-hui
Institution:Institute of Foundation Engineering, China Academy of Building Research, Beijing 100013, China
Abstract:Through the indoor model tests, lateral earth pressures exerted by natural foundation and rigid pile composite foundation against rigid retaining walls without any displacements are measured. The distribution of lateral earth pressures of rigid pile composite foundation is obtained by the comparison with that of natural foundation. It is believed that participation of pile in rigid pile composite foundation makes magnitude and distribution of lateral earth pressure different from natural foundation. In this place, pile participation includes the deep transfer function of pile load, the influence of pile negative friction and the pile "block" effect on level additional stress of soil between piles. The influence range of lateral earth pressure of rigid pile composite foundation with surcharge is deeper than that of natural foundation. Besides, the value of lateral earth pressure of rigid pile composite foundation is smaller than that of natural foundation at the same location under the same subgrade pressure. In the test conditions of this study, the total and the additional earth pressure exerted by the rigid pile composite foundation on the rigid retaining walls are about 43.3%~80.1% and 15.9%~59.8% of the total earth pressure of the natural foundation respectively when the load level reaches the characteristic value of the foundation capacity within the range of 0.35 to1.4 m from the rigid retaining wall to the building.
Keywords:rigid pile composite foundation  lateral earth pressure  overload  model test
本文献已被 CNKI 等数据库收录!
点击此处可从《岩土力学》浏览原始摘要信息
点击此处可从《岩土力学》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏