首页 | 本学科首页   官方微博 | 高级检索  
     检索      


An accurate strength amplification factor for the design of SDOF systems with P–Δ effects
Authors:Fabio Amara  Melina Bosco  Edoardo M Marino  Pier Paolo Rossi
Institution:Department of Civil and Environmental Engineering, University of Catania, Catania, Italy
Abstract:The response of structures subjected to seismic actions is always influenced by P–Δ effects. The importance of this effect is generally modest for structures experiencing an elastic response but often relevant for structures responding well within the inelastic range of behaviour. Seismic codes indicate that P–Δ effects may be counterbalanced through an increase in the structural strength required by a first order analysis. This increase is calculated by means of a strength amplification factor. The expressions suggested in codes for this factor are simplistic and often criticized by researchers. In this paper, the effectiveness of some of the provisions reported in the literature or suggested in seismic codes is evaluated on single degree of freedom systems with different periods of vibration. As suggested by past studies, attention is focused on the influence of the interstorey drift sensitivity coefficient, significant duration of the ground motion, class of the site soil, displacement ductility and equivalent viscous damping ratio of the system. Finally, an accurate expression of the strength amplification factor is proposed. Copyright © 2013 John Wiley & Sons, Ltd.
Keywords:seismic actions  P–  Δ  effects  SDOF system  design provisions
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号