首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Ⅰ期浸润性肺腺癌磨玻璃影及附壁样生长三维CT值定量分析
引用本文:刘丽伟,张龙江,钱斌.Ⅰ期浸润性肺腺癌磨玻璃影及附壁样生长三维CT值定量分析[J].CT理论与应用研究,2018,27(1):115-121.
作者姓名:刘丽伟  张龙江  钱斌
作者单位:1. 江苏省太湖疗养院放射科, 江苏 无锡 214000;
摘    要:目的:探究采用三维CT值定量分析Ⅰ期浸润性肺腺癌磨玻璃影及其与病理上附壁样生长成分的相关性。方法:选取2013年6月至2017年6月收治的Ⅰ期浸润性肺腺癌患者168例,采用三维CT值定量分析软件及最大径线测量法计算Ⅰ期浸润性肺腺癌磨玻璃影成分比例,对浸润性腺癌的附壁样生长成分实施半定量评估,并对两者进行相关性分析。结果:采用三维CT值定量分析测量取得磨玻璃影成分比例为(0.21±0.18),根据最大径线法测量取得磨玻璃影成分比例为(0.44±0.36),病理切片半定量分析测量附壁成分比例为(0.29±0.24)。采用三维CT值定量及最大径线法分析测量所取得的磨玻璃影成分比例与附壁样生长成分比例均呈正相关(r=0.634和0.598,P=0.000)。最大径线法测得磨玻璃影成分比例与附壁样生长成分比例有3.8%在95%可信区间以外,三维CT值定量分析为4.4%,两者差异无统计学意义(P>0.05)。结论:通过三维值定量分析Ⅰ期浸润性肺腺癌患者磨玻璃影成分与附壁样生长成分具有显著相关性,其对辅助病理诊断具有重要临床意义,相比于最大径线法更能够全面反映Ⅰ期浸润性肺腺癌肿瘤的状况。 

关 键 词:肺腺癌    磨玻璃影    三维CT值定量分析    相关性
收稿时间:2017-10-27

3D CT Value Analysis of Ground Glass Shadow and Coelentereous Growth in Stage ⅠInvasive Lung Adenocarcinoma
LIU Li-wei,ZHANG Long-jiang,QIAN Bin.3D CT Value Analysis of Ground Glass Shadow and Coelentereous Growth in Stage ⅠInvasive Lung Adenocarcinoma[J].Computerized Tomography Theory and Applications,2018,27(1):115-121.
Authors:LIU Li-wei  ZHANG Long-jiang  QIAN Bin
Institution:1. Department of Radiology, Jiangsu Taihu Ursing homes, Wuxi 214000, China;2. Department of Medical Imaging, Wuxi People's Hospital Affiliated to NJMU, Wuxi 214023, China
Abstract:Objective: To investigate the relationship between ground glass opacity and the pathologic climax-like growth in patients with stage I invasive lung adenocarcinoma by three-dimensional CT. Methods: A total of 168 patients with stage Ⅰ invasive pulmonary adenocarcinoma who were treated from June 2013 to June 2017 were selected. The components of ground glass in stage Ⅰ invasive lung adenocarcinoma were calculated by three-dimensional CT quantitative analysis software and the largest radial line measurement ratio, semi-quantitative assessment of the invasive growth of the adherent adenocarcinoma composition, and the correlation between the two. Results: The proportion of ground glass components was (0.21 ±0.18), the percentage of ground glass components was (0.44 ±0.36), the semi-quantitative analysis of pathological sections the ratio was (0.29 ±0.24). There was a positive correlation between the proportion of ground glass components and the proportion of climax-like growth components (r = 0.634 and 0.598, P = 0.000) by three-dimensional CT quantitative analysis and maximum diameter line analysis. The ratio of ground glass to the ratio of ground-glass components measured by the maximum diameter method was 3.8%. Outside the 95% confidence interval, the three-dimensional CT value was 4.4%. There was no significant difference between the two methods (P > 0.05). Conclusion: The three-dimensional quantitative analysis of stage I invasive lung adenocarcinoma patients with ground-glass components and climax-like growth component has a significant correlation, which has a significant clinical significance in the diagnosis of secondary pathology, and compared to the maximum diameter method is more comprehensive reflect the stage I invasive lung adenocarcinoma of the tumor status.
Keywords:
本文献已被 万方数据 等数据库收录!
点击此处可从《CT理论与应用研究》浏览原始摘要信息
点击此处可从《CT理论与应用研究》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号