首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Stick-slip behavior of Indian gabbro as studied using a NIED large-scale biaxial friction apparatus
Authors:Tetsuhiro Togo  Toshihiko Shimamoto  Futoshi Yamashita  Eiichi Fukuyama  Kazuo Mizoguchi  Yumi Urata
Institution:1.State Key Laboratory of Earthquake Dynamics, Institute of Geology, China Earthquake Administration, Beijing 100029, China2.Geological Survey of Japan, AIST Tsukuba Central 7, Tsukuba, Japan3.National Research Institute for Earth Science and Disaster Prevention (NIED), Tsukuba, Japan4.Central Research Institute of Electric Power Industry, Chiba 270-1194, Japan
Abstract:This paper reports stick-slip behaviors of Indian gabbro as studied using a new large-scale biaxial friction apparatus, built in the National Research Institute for Earth Science and Disaster Prevention (NIED), Tsukuba, Japan. The apparatus consists of the existing shaking table as the shear-loading device up to 3, 600 kN, the main frame for holding two large rectangular prismatic specimens with a sliding area of 0.75 m2 and for applying normal stresses σn up to 1.33 MPa, and a reaction force unit holding the stationary specimen to the ground. The shaking table can produce loading rates v up to 1.0 m/s, accelerations up to 9.4 m/s2, and displacements d up to 0.44 m, using four servocontrolled actuators. We report results from eight preliminary experiments conducted with room humidity on the same gabbro specimens at v = 0.1-100 mm/s and σn = 0.66-1.33 MPa, and with d of about 0.39 m. The peak and steady-state friction coefficients were about 0.8 and 0.6, respectively, consistent with the Byerlee friction. The axial force drop or shear stress drop during an abrupt slip is linearly proportional to the amount of displacement, and the slope of this relationship determines the stiffness of the apparatus as 1.15×108 N/m or 153 MPa/m for the specimens we used. This low stiffness makes fault motion very unstable and the overshooting of shear stress to a negative value was recognized in some violent stick-slip events. An abrupt slip occurred in a constant rise time of 16-18 ms despite wide variation of the stress drop, and an average velocity during an abrupt slip is linearly proportional to the stress drop. The use of a large-scale shaking table has a great potential in increasing the slip rate and total displacement in biaxial friction experiments with large specimens.
Keywords:Stick-slip in gabbro  Biaxial friction apparatus  Shaking table  Friction experiment  Fault mechanics
点击此处可从《Earthquake Science》浏览原始摘要信息
点击此处可从《Earthquake Science》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号