首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Nonlinear pushover analysis of infilled concrete frames
Authors:Email author" target="_blank">Chao?Hsun?HuangEmail author  Yungting?Alex?Tuan  Ruo?Yun?Hsu
Institution:1. Department of Civil Engineering, Taipei University of Technology, Chinese Taipei
2. Department of Construction, Tamkang University, Chinese Taipei
3. Tien Shiang Structural and Civil Association, Chinese Taipei
Abstract:Six reinforced concrete frames with or without masonry infills were constructed and tested under horizontal cyclic loads. All six frames had identical details in which the transverse reinforcement in columns was provided by rectangular hoops that did not meet current ACI specifications for ductile frames. For comparison purposes, the columns in three of these frames were jacketed by carbon-fiber-reinforced-polymer (CFRP) sheets to avoid possible shear failure. A nonlinear pushover analysis, in which the force-deformation relationships of individual elements were developed based on ACI 318, FEMA 356, and Chen’s model, was carried out for these frames and compared to test results. Both the failure mechanisms and impact of infills on the behaviors of these frames were examined in the study. Conclusions from the present analysis provide structural engineers with valuable information for evaluation and design of infilled concrete frame building structures. Supported by: Science Council of Chinese Taipei Under Grant No. SC-92-2625-Z-027-003
Keywords:pushover analysis  FEMA 356  infilled concrete frames  infill masonry panels  fiber-reinforced-polymer
本文献已被 CNKI 维普 万方数据 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏