首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Hydro-thermal coupled analysis for health monitoring of embankment dams
Authors:Tewodros Y Yosef  Chung R Song  Ki-Tae Chang
Institution:1.Department of Civil Engineering,University of Nebraska-Lincoln,Lincoln,USA;2.Department of Civil Engineering,University of Nebraska-Lincoln,Lincoln,USA;3.Department of Civil Engineering,Kumoh National University of Technology,Gumi,Korea
Abstract:Measuring and analyzing internal dam temperature may provide insight into evaluating the integrity of earthen dams. Temperature in a dam, with the advent of modern distributed temperature sensing (DTS) technique, is conveniently measured. The analysis of the temperature is conducted based on a hydro-thermal coupled analysis technique. In this study, DTS-based temperature data and VS2DHI (a finite difference code for analyzing two-dimensional heat transport in porous media) were used to analyze the hydro-thermal coupled behavior in a dam. The results of this analysis show that the temperature variation in an earthen dam is closely related to seepage conditions. Additionally, a localized high-temperature (26 °C) zone found in the measured data of the dam, which raised concern to engineers on site, is explained through either hot water infiltration into the foundation layer or lower permeability of the foundation layer than the magnitude that appeared in the design document. These findings demonstrate that hydro-thermal coupled analysis has the potential for evaluating the integrity of earthen dams.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号