高频红外法测定石墨样品中的固定碳
引用本文:周晓磊,刘忠胜.高频红外法测定石墨样品中的固定碳[J].吉林地质,2011,30(4):93-94,116.
作者姓名:周晓磊  刘忠胜
作者单位:1. 吉林省第三地质调查所,吉林四平,136000
2. 吉林省地质科学研究所,吉林长春,130012
摘    要:采用硝酸酸化处理,低温焙烧氧化除去无机碳及有机碳,样品于高频红外碳硫分析仪测定固定碳质量分数,经国家标准物质验证,测定值与标准值相符,方法精密度RSD%为0.71,检出限为0.02%,满足石墨低品位固定碳质量分数分析质量要求。

关 键 词:高频红外法  石墨样品  固定碳

Determination of fixed carbon in the graphite samples by high frequency IR-absorption spectrometric method
ZHOU Xiao-lei,LIU Zhong-sheng.Determination of fixed carbon in the graphite samples by high frequency IR-absorption spectrometric method[J].Jilin Geology,2011,30(4):93-94,116.
Authors:ZHOU Xiao-lei  LIU Zhong-sheng
Institution:1.The Third Geological Survey of Jilin Province,Siping,136000,Jilin,China;2.Jilin Institute of Geological Sciences,Changchun 130012,Jilin,China
Abstract:The graphite samples were decomposed with nitric acid,low-temperature roasting to remove inorganic carbon and organic carbon,the fixed carbon content in the samples were determined by high frequency IR-Absorption carbon/sulfur determinator,The method has been validated by National Standard Reference materials and the result is in agreement with certified value with precision of 0.71%RSD,the detection limit of method was 0.02%,The method is suitable for determining fixed carbon content of low grade graphite.
Keywords:high frequency IR-absorption spectrometric  graphite samples  fixed carbon