首页 | 本学科首页   官方微博 | 高级检索  
     检索      

2004年11月强磁暴期间武汉电离层TEC的响应和振幅闪烁特征的GPS观测
引用本文:徐继生,朱劼,程光晖.2004年11月强磁暴期间武汉电离层TEC的响应和振幅闪烁特征的GPS观测[J].地球物理学报,2006,49(4):950-956.
作者姓名:徐继生  朱劼  程光晖
作者单位:武汉大学电子信息学院,武汉,430079;武汉大学电子信息学院,武汉,430079;武汉大学电子信息学院,武汉,430079
基金项目:国家自然科学基金项目(40474055)资助.
摘    要:本文利用设在武汉(11436°E,3053°N,磁纬194°)的GPS电离层TEC和电波闪烁监测仪的测量数据,分析了2004年11月强磁暴期间TEC的响应以及电波闪烁和TEC起伏的特征.结果表明,在这次强磁暴期间,武汉及其邻近地区电离层TEC的响应以正暴相为主,正暴相分别出现在两次主相期间,最大正偏离达到50 TECU.这次磁暴另一个重要影响是主相期间L波段振幅闪烁的活动性及其强度显著增强.S4指数最大接近10.伴随增强的闪烁活动,多次观测到深度耗尽的等离子体泡与TEC起伏,TEC变化率的标准差ROTI指数也显著增强.分析揭示, ROTI指数与S4指数呈正相关,相关系数达到097.线性回归计算得到,ROTI和S4的比率为964.

关 键 词:全球定位系统  电离层    总电子含量  闪烁
文章编号:0001-5733(2006)04-0950-07
收稿时间:2005-11-21
修稿时间:2005-11-212006-04-12

GPS observations of ionospheric effects of the major storm of Nov.7-10, 2004
XU Ji-Sheng,ZHU Jie,CHENG Guang-Hui.GPS observations of ionospheric effects of the major storm of Nov.7-10, 2004[J].Chinese Journal of Geophysics,2006,49(4):950-956.
Authors:XU Ji-Sheng  ZHU Jie  CHENG Guang-Hui
Institution:College of Electronic Informatics, Wuhan University, Wuhan 430079, China
Abstract:The TEC and amplitude scintillation measurements of L1 (1575 GHz) signals from GPS satellites have been carried out at Wuhan(11436°E, 3053°N, magnetic latitude 194°) since 2003 using an ionospheric total electron content(TEC) and scintillation monitor to investigate the ionospheric irregularities and TEC disturbances at the region of the equatorial anomaly. In this paper ionospheric effects of the magnetic storm of November, 2004 are analyzed by using GPS observations. Data analysis shows that the ionospheric storm during this magnetic storm mainly exhibits the positive storm phase around Wuhan, and the positive deviations of TECs occur during two main phases of the storm on November 8 and 10 with the largest deviation of 50 TECU. Another primary effect of the storm on the ionosphere is the remarkably enhanced activity and intensity of amplitude scintillations during the later main phase. The maximum value of the S4 index exceeded 10 There occurred plasma bubbles and TEC fluctuations initiated from the equatorial region repetitiously at the same time when strong amplitude scintillations occurred. A comparison between amplitude scintillations and TEC fluctuations was made. The statistic analysis shows there is a remarkable positive correlation between standard deviation of the change rate of TEC, the ROTI index, and the S4 index. Through a regression analysis it is obtained that the ratio of ROTI to S4 is 964
Keywords:GPS  Ionosphere  Storm  TEC  Scintillation
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《地球物理学报》浏览原始摘要信息
点击此处可从《地球物理学报》下载免费的PDF全文