首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Measurement of Na and I recoil discrimination and detection efficiency in a cooled ‘UVIS’ NaI crystal for dark matter searches
Authors:N J C Spooner  G J Davies  C H Lally  N J T Smith  M van den Putte  P F Smith  J D Lewin  G T A Squier  P Jagpal
Institution:

a Department of Physics, The Hicks Building, University of Sheffield Sheffield, S3 7RH UK

b Imperial College, Blackett Laboratory, Prince Consort Rd. London, SW7 2BZ UK

c Rutherford Appleton Laboratory, Chilton Oxon., OX11 0QX UK

d Physics Department, University of Birmingham, Edgbaston Birmingham, B15 2TT UK

Abstract:The UVIS dark matter detector, proposed by Spooner and Smith (Phys. Lett. B 314 (1993) 430), consists of < 1000 ppm Tl doped NaI scintillator operated at 100-200 K, with measurement of UV and visible scintillation components used to discriminate between electrons (gammas) and Na or I recoils. Presented here are results of measurements of the gamma/nuclear recoil discrimination power of a Kyropolous NaI (0.5 ppm Tl) UVIS test detector operated at 160 K, with monoenergetic neutrons used to induce nuclear recoils via elastic scattering. Defining the statistical gain factor for N events as Image , the coefficient Cm was measured as a function of photoelectron pulse height. At 40 photoelectrons Cm was found to be 0.5 (corresponding to 90% rejection of gammas with 20% loss of neutron events). The scintillation efficiency for Na and I recoils relative to electrons was also measured at 160 K and found to be 35 ± 5% for Na recoils and 10 ± 2% for iodine.
Keywords:WIMPS  Neutralino  Low background