Seismic evaluation of earthquake resistance and retrofitting measures for two story masonry houses |
| |
Authors: | Navaratnarajah Sathiparan Kotaro Sakurai Muneyoshi Numada Kimiro Meguro |
| |
Institution: | 1. Department of Civil and Environmental Engineering, University of Ruhuna, Galle, Sri Lanka 2. Institute of Industrial Science, The University of Tokyo, Tokyo, Japan 3. ICUS, Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
|
| |
Abstract: | This paper discusses on the shaking table test results of two 1:4 scale model of two-story masonry structure typically used in constructing low-rise residential buildings. This test is performed to provide a better understanding of the seismic behavior of the PP-band (polypropylene band) mesh retrofitted adobe masonry house. The test structure is subjected to a series of different levels of harmonic motion that applied along the longitudinal direction. The results of the shaking table tests on building models show that the PP-band retrofitting technique can enhance the safety of masonry buildings, even during severe ground motion. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|