首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Measurement of atmospheric total ozone by the filter photometric method
Authors:Poonam Mehra  R Vijayakumar  A Mary Selvam
Institution:(1) Indian Institute of Tropical Meteorology, 411 005 Pune, India
Abstract:The total ozone content in the atmosphere was determined from the multichannel photometer observations of direct solar radiation made in the urban environment at Pune (18° 32prime N, 73° 51primeE, 559 m ASL) and Sinhagad hill station (18° 22primeN, 73° 45primeE, 1305 m ASL) during March 1980-February 1982. The total ozone content of the atmosphere was computed making use of the differential absorption of solar radiation due to ozone at 0.4 and 0.6 mgrm wavelengths in the Chappuis band. The values of the ozone data obtained from the photometer observations at Pune and Sinhagad were compared with the corresponding ozone data obtained from the Dobson spectrophotometer located at Pune. Values of ozone obtained by the photometric method were found to be smaller by 8–18% than the Dobson values when Vigroux's absorption coefficients were used. Similarly, when the absorption coefficients of Inn and Tanaka (1953) were used, the ozone values obtained by the photometric method were smaller by 4–14% than the Dobson values. The ozone values at the hill station obtained from the photometric method were in better agreement (5%) with the Dobson values.
Keywords:Chappuis band absorption  ozone optical thickness  Dobson spectrophotometer  Vigroux's absorption coefficient  multichannel photometer
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏