首页 | 本学科首页   官方微博 | 高级检索  
     检索      

新型水氡仪质量检测及台站比测实验研究
引用本文:赵影,胡旭东,肖孟仁,鲍志诚,宁洪涛,王成楠,黄仁桂.新型水氡仪质量检测及台站比测实验研究[J].西北地震学报,2022,44(1):166-171.
作者姓名:赵影  胡旭东  肖孟仁  鲍志诚  宁洪涛  王成楠  黄仁桂
作者单位:江西九江扬子块体东部地球动力学野外科学观测研究站;江西省地震局;东华理工大学;江西省地质环境调查研究院
基金项目:江西九江扬子块体东部地球动力学野外科学观测研究站开放基金项目(OGYB202001);中国地震局监测、预测、科研三结合课题(3JH-202001053)。
摘    要:针对目前地震水氡模拟观测操作繁琐、干扰因素多等现状,引入新型水氡观测仪进行检测并与FD-125测氡仪开展对比试验研究。两款水氡观测仪在地震监测氡观测仪检测平台标准氡室校准,并依托九江地震台相同水样和环境下开展对比测量表明,在静置时间为1 h前提下,新型水氡观测仪重复性、相对误差、相对固有误差、固有本底符合技术要求,与FD-125测氡仪对比测量数据的一致性较好,但灵敏度指标有待提升。该仪器整体设计基本满足地震模拟水氡测量发展需求,可减少人工操作带来的测量误差,提升测量效率和数据质量。

关 键 词:BG2015D双通道测氡仪  FD-125测氡仪  标准氡室  对比测量

Quality detection and comparative experimentof a novel water radon detector
ZHAO Ying,HU Xudong,XIAO Mengren,BAO Zhicheng,NING Hongtao,WANG Chengnan,HUANG Rengui.Quality detection and comparative experimentof a novel water radon detector[J].Northwestern Seismological Journal,2022,44(1):166-171.
Authors:ZHAO Ying  HU Xudong  XIAO Mengren  BAO Zhicheng  NING Hongtao  WANG Chengnan  HUANG Rengui
Institution:(Observatory for Geodynamic of the East Yangtze Block in Jiujiang Province, Jiujiang 332006, Jiangxi, China;Jiangxi Earthquake Agency, Nanchang 330026, Jiangxi, China;East China University of Technology, Nanchang 330013, Jiangxi, China;Jiangxi Province Geological and Environmental Research Institute, Nanchang 330026, Jiangxi, China)
Abstract:The simulated observation of water radon in China is cumbersome and has many interference factors.To overcome this drawback,a novel radon detector instrument was introduced in this paper,and a comparative experimental study was carried out with the FD-125 radon detector.The two water radon detectors were calibrated in the standard radon chamber of the emanometer measurement platform for earthquake monitoring,and a comparative measurement with the same water samples and environment was carried out at Jiujiang seismic station.The results show that the repeatability,relative error,relative inherent error,and inherent background of the novel radon detector can meet the technical requirements with a standing time of 1 h.The observation data has good consistency with those of FD-125 radon detector,but the sensitivity index needs to be improved.The overall design of the proposed instrument can basically meet the development needs of analog water radon observation and reduce the measurement error caused by manual operation,thus improving the measurement efficiency and data quality.
Keywords:BG2015D dual channel radon detector  FD-125 radon detector  standard radon chamber  comparative measurement
本文献已被 维普 等数据库收录!
点击此处可从《西北地震学报》浏览原始摘要信息
点击此处可从《西北地震学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号