首页 | 本学科首页   官方微博 | 高级检索  
     检索      


The Herschel-PACS photometer calibration
Authors:Zoltan Balog  Thomas Müller  Markus Nielbock  Bruno Altieri  Ulrich Klaas  Joris Blommaert  Hendrik Linz  Dieter Lutz  Attila Moór  Nicolas Billot  Marc Sauvage  Koryo Okumura
Institution:1. Max-Planck-Institut für Astronomie, K?nigstuhl 17, 69117, Heidelberg, Germany
2. Max-Planck-Institut für Extraterrestrische Physik, Garching, Germany
3. ESAC, Madrid, Spain
4. Instituut voor Sterrenkunde, K.U. Leuven, Leuven, Belgium
5. Konkoly Observatory, Budapest, Hungary
6. IRAM, Granada, Spain
7. CEA, Saclay, France
Abstract:This paper provides an overview of the PACS photometer flux calibration concept, in particular for the principal observation mode, the scan map. The absolute flux calibration is tied to the photospheric models of five fiducial stellar standards (α Boo, α Cet, α Tau, β And, γ Dra). The data processing steps to arrive at a consistent and homogeneous calibration are outlined. In the current state the relative photometric accuracy is ~2 % in all bands. Starting from the present calibration status, the characterization and correction for instrumental effects affecting the relative calibration accuracy is described and an outlook for the final achievable calibration numbers is given. After including all the correction for the instrumental effects, the relative photometric calibration accuracy (repeatability) will be as good as 0.5 % in the blue and green band and 2 % in the red band. This excellent calibration starts to reveal possible inconsistencies between the models of the K-type and the M-type stellar calibrators. The absolute calibration accuracy is therefore mainly limited by the 5 % uncertainty of the celestial standard models in all three bands. The PACS bolometer response was extremely stable over the entire Herschel mission and a single, time-independent response calibration file is sufficient for the processing and calibration of the science observations. The dedicated measurements of the internal calibration sources were needed only to characterize secondary effects. No aging effects of the bolometer or the filters have been found. Also, we found no signs of filter leaks. The PACS photometric system is very well characterized with a constant energy spectrum νF ν = λF λ = const as a reference. Colour corrections for a wide range of sources SEDs are determined and tabulated.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号