首页 | 本学科首页   官方微博 | 高级检索  
     检索      

大气CO2标准气浓度标定及采样瓶CO2浓度分析系统
引用本文:张晓春,蔡永祥,温玉璞,周凌晞,汤洁.大气CO2标准气浓度标定及采样瓶CO2浓度分析系统[J].气象科技,2005,33(6):538-542547.
作者姓名:张晓春  蔡永祥  温玉璞  周凌晞  汤洁
作者单位:1. 北京大学物理学院大气科学系,北京,100871;中国气象科学研究院,中国气象局大气成分观测与服务中心,中国气象局大气化学重点开放实验室,北京,100081
2. 中国大气本底基准观象台,西宁,810001
3. 中国气象科学研究院,中国气象局大气成分观测与服务中心,中国气象局大气化学重点开放实验室,北京,100081
基金项目:科技部基础性工作项目G99A07“大陆大气基准研究”资助
摘    要:对美国NOAA/CMDL开发的用于我国大气本底监测的非色散红外CO2瓶分析和标准气标定系统做了测试与讨论,并对在青海瓦里关、浙江临安、黑龙江龙凤山和北京上甸子所采集到的实验性空气样品中的CO2浓度进行了测量,与瓦里关在线连续测量结果进行了对比,结果均表明该系统具有较高的灵敏度、精确度和较好的稳定性,具备了从进样到数据处理等较为完整的自动化功能,具有简便易行、准确可靠等特点,可用于大气CO2标准气体的标定及采样瓶分析。测量和对比结果也表明,样瓶采样和分析系统可在一定程度上替代现场连续测量系统,在不同的地点进行采样并进行集中分析也是一种较为经济、实用的方法。

关 键 词:红外分析  CO2  标定  标准气  瓶采样
收稿时间:2004-07-26
修稿时间:2004-07-262005-02-19

Study of Atmospheric Carbon Dioxide Calibration and Flask Sample Analysis System
Zhang Xiaochun,Cai Yongxiang,Wen Yupu,Zhou Lingxi,Tang Jie Centre for Atmosphere Watch and Services,Key Laboratory for Atmospheric Chemistry,CMA,Beiiing ;. China Global Atmosphere Watch Baseline Observatory,Xining.Study of Atmospheric Carbon Dioxide Calibration and Flask Sample Analysis System[J].Meteorological Science and Technology,2005,33(6):538-542547.
Authors:Zhang Xiaochun  Cai Yongxiang  Wen Yupu  Zhou Lingxi  Tang Jie Centre for Atmosphere Watch and Services  Key Laboratory for Atmospheric Chemistry  CMA  Beiiing ; China Global Atmosphere Watch Baseline Observatory  Xining
Institution:1.School of Physics, Peking University, Beijing 100871 ; 2. Chinese Academy of Meteorological Sciences (CAMS;CAWAS;LAC
Abstract:The study focuses on a test and discussion of non-dispersive infrared CO_2 flask sample analysis and standard gas calibration system developed by NOAA/CMDL and used in the baseline atmosphere monitoring in China with the mixing ratios of carbon dioxide in the flask air samples tentatively taken at Waliguan(Qinghai), Linan(Zhejiang),Longfengshan(Heilongjian) and Shangdianzi(Beijing) being measured.Meanwhile,a comparison was made with the continuous online measurements at Waliguan.The results all indicate that the system is of high-level sensitivity,precision and stability with an automatic function from sample injection to data processing.It can be applied to the calibration of CO_2 standard gases and the analysis of flask samples,being easy-operating and reliable.The air sampling and analyzing system can be used,to some extent,instead of the in-situ continuously monitoring system.It is also an economical and practical way to take samples in different sites and analyze together
Keywords:infrared analysis  carbon dioxide  calibration  standard gas  flask sampling
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《气象科技》浏览原始摘要信息