首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Fourier transform measurement of NO2 absorption cross-section in the visible range at room temperature
Authors:A C Vandaele  C Hermans  P C Simon  M Van Roozendael  J M Guilmot  M Carleer  R Colin
Institution:(1) Institut d'Aéronomie Spatiale de Belgique, 3 av. Circulaire, B-1180 Brusels, Belgium;(2) Laboratoire de Chimie Physique, Université Libre de Bruxelles, 50 av F.D. Roosevelt, CP 160/09, B-1050 Brussels, Belgium
Abstract:New laboratory measurements of NO2 absorption cross-section were performed using a Fourier transform spectrometer at 2 and 16 cm-1 (0.03 and 0.26 nm at 400 nm) in the visible range (380–830 nm) and at room temperature. The use of a Fourier transform spectrometer leads to a very accurate wavenumber scale (0.005 cm-1, 8×10-5 nm at 400 nm). The uncertainty on the new measurements is better than 4%. Absolute and differential cross-sections are compared with published data, giving an agreement ranging from 2 to 5% for the absolute values. The discrepancies in the differential cross-sections can however reach 18%. The influence of the cross-sections on the ground-based measurement of the stratospheric NO2 total amount is also investigated.
Keywords:Fourier transform spectroscopy  NO2  absorption cross-sections  differential absorption cross-sections  visible  stratospheric and tropospheric measurements
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏