首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Ground Water Remediation Using an Extraction, Treatment, and Recharge System
Authors:Kurt O Thomsen  Majid A Chaudhry  Kostas Dovantzis  Ronald R Riesing
Abstract:Ground water remediation of volatile organic compound (VOC) contamination at a site in Michigan was initiated as a result of a consent agreement between the Michigan Department of Natural Resources (MDNR) and the responsible party. Under the direction of the MDNR, the responsible party conducted a remedial investigation/feasibility study using federal guidelines to define the extent of contamination at the site and to select a response action for site remediation. The selected alternative included a combination of ground water extraction, treatment, and recharge, and soil flushing. The extraction system withdraws ground water from various depths in heavily contaminated areas. The ground water is treated using an air stripper. A spray distribution system spreads effluent from the stripper over a recharge basin constructed over the most contaminated areas. Additional contaminant removal is achieved by volatilization from the spray and percolation through the gravel bed. Recharge water moves downward through the contaminated soils, thus flushing residual soil contaminants. The initial operating data demonstrated that the system can effectively remove trichloroethylene (TCE) from ground water (approximately 95 percent overall removal efficiency). The annualized capital and operation and maintenance (O & M) costs of the remedial action were estimated for several operating periods (15, 20, and 30 years).
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号