首页 | 本学科首页   官方微博 | 高级检索  
     检索      

钢-混凝土高层结构抗震性能振动台试验研究
引用本文:黄襄云,曹京源,马玉宏,徐丽,陈建秋,吴迪.钢-混凝土高层结构抗震性能振动台试验研究[J].地震工程与工程振动,2011,31(2):68-74.
作者姓名:黄襄云  曹京源  马玉宏  徐丽  陈建秋  吴迪
作者单位:广州大学工程抗震研究中心,广东省地震工程与应用技术重点实验室,广东,广州,510405
基金项目:国家自然科学基金资助,广州市属高校科技计划项目
摘    要:广州天誉大厦采用型钢混凝土框架一钢筋混凝土筒体的混合结构体系,地面以上结构采用抗震缝兼伸缩缝分隔为南、北塔两个独立结构体系,南塔高186.5 m,北塔高159.5 m.两塔的核心筒总宽度与核心筒总高的比值均超出了规范限值.为研究这种超限高层混合结构的抗震性能,对其进行了缩尺(1/30)模型的振动台试验,并建立了有限元计...

关 键 词:超限高层建筑  钢-混凝土混合结构  振动台试验  抗震性能

Experimental study on seismic behavior of a steel-concrete composite structure for a high-rise building
HUANG Xiangyun,CAO Jingyuan,MA Yuhong,XU Li,CHEN Jianqiu,WU Di.Experimental study on seismic behavior of a steel-concrete composite structure for a high-rise building[J].Earthquake Engineering and Engineering Vibration,2011,31(2):68-74.
Authors:HUANG Xiangyun  CAO Jingyuan  MA Yuhong  XU Li  CHEN Jianqiu  WU Di
Institution:HUANG Xiangyun,CAO Jingyuan,MA Yuhong,XU Li,CHEN Jianqiu,WU Di(Earthquake Engineering Research & Test Center,Guangzhou University,Guangdong Provincial Key Laboratoryof Earthquake Engineering and Advanced Technology,Guangzhou 510405,China)
Abstract:Guangzhou TianYu Building is a steel reinforced concrete frame-reinforced concrete core walls hybrid structure system.It is divided into two independent structural systems——north and south tower by seismic joint.South tower is 186.5 meters high and north tower is 159.5 meters high.North and south towers’ aspect ratio and the ratio of the total width of the core tube to the height of core tube are all beyond normal limits.In order to provide seismic resistant design basis for this high-rise hybrid building,Earthquake Engineering Research & Test Center of Guangzhou University conducted(1/30) scale model shaking table test,and used finite element software ETABS for modal analysis and time-history analysis.Test and analysis results show that the structural system has sufficient horizontal stiffness.On the whole,the structure meets the seismic requirements.In major earthquake,the relative displacement of the south and north towers and the story drift angle are so large that north tower and south tower would collide.It is suggested that increasing the distance between the two towers suitably or taking energy dissipation measures should be done.
Keywords:transfinite high-rise building  steel-concrete composite structure  shaking table test  seismic behavior  
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号