Determination of arsenic(III) for the investigation of the microbial oxidation of arsenic(III) to arsenic(V)
Authors:B Hambsch  B Raue  H-J Brauch
Abstract:Recent evaluations of acute and chronical toxicity of arsenic resulted in a reduction of the standard value for total arsenic from 40 μg/L to 10 μg/L in drinking water which will be valid in Germany after a transition period as from January 1996. Arsenic is well known as substance of deep groundwaters, mainly of geogenic origin and normally found as As(III) or As(V). As(V) is well removable by flocculation and filtration after adding iron salts. As(III), however, has to be oxidized first to As(V). Therefore, it is important for treatment techniques to be able to distinguish between As(III) and As(V). A modified determination of As(III) using flow injection analysis was installed and optimized in order to investigate whether As(III) may be oxidized to As(V) by bacteria in natural waters. The results showed that at 4°C, no As(III)-oxidation was observed within 14 days. At room temperature, however, in the bacteria-containing samples, an As(III)-oxidation was found starting after 3 to 7 days. After 14 days, no As(III) was left over. In contrast, in the sterile samples, no As(III)-oxidation could be observed within 14 days. These results demonstrated that microbial processes influence the oxidation of As(III) to As(V) in natural waters.
Keywords:Deep Groundwaters  As Species  Microbial Oxidation of As(III)