首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Removal of Natural Free Estrogens and their Conjugates in a Municipal Wastewater Treatment Plant
Authors:Ze‐hua Liu  Yoshinori Kanjo  Satoshi Mizutani
Institution:Graduate School of Engineering, Osaka City University, Osaka, Japan
Abstract:Removal of natural free estrogens and estrogen conjugates in a municipal wastewater treatment plant (WWTP) was investigated and analyzed by GC‐MS, in which estrogen conjugates were first transformed to their corresponding free estrogens with an acid solvolysis procedure before their analysis. Natural free estrogens, E1‐3‐sulfate (E1‐3S), and E3‐3‐sulfate (E3‐3S) were detected with high concentrations in both the influent and effluent of the primary settling tank (PS), while no estrogen glucuronides were detected in any of the monitored wastewater samples. Regarding their removal efficiencies, all were almost completely removed, except for E1 with only a minor decrease. The estrogenic/androgenic removal of the same WWTP was also evaluated with estrogen receptor (androgen receptor) (ER (AR))‐binding assays, in which the removal efficiencies for E2 equivalents (EEQ) or testosterone equivalents (TEQ) were 68.5 and 72.2%. In addition, the chemically calculated EEQ from natural estrogens were about 20.6–39.3% that of the ER‐binding assay, in which E3 contributed the biggest proportion in both the influent and PS, while the calculated value of E1 increased from only 6.7% in the influent to as high as 20.6% in the effluent.
Keywords:Estrogen conjugate  ER (AR)‐binding assay  GC‐MS  Natural free estrogen  Removal efficiency
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号