首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Study on the Influence of Airgun Excitation Conditions on Airgun Signals and Travel Time Variation Measurements
作者姓名:XIANG Y  YANG Runhai  WANG Bin  ZHOU Yunyao  LU Yongqing  WU Huan  QI Junwei  PENG Jing
作者单位:Key Laboratory of Earthquake Geodesy, Institute of Seismology, CEA, Wuhan 430071, China,Yunnan Earthquake Agency, Kunming 650224, China,Yunnan Earthquake Agency, Kunming 650224, China,Key Laboratory of Earthquake Geodesy, Institute of Seismology, CEA, Wuhan 430071, China,Key Laboratory of Earthquake Geodesy, Institute of Seismology, CEA, Wuhan 430071, China,Key Laboratory of Earthquake Geodesy, Institute of Seismology, CEA, Wuhan 430071, China,Key Laboratory of Earthquake Geodesy, Institute of Seismology, CEA, Wuhan 430071, China,Key Laboratory of Earthquake Geodesy, Institute of Seismology, CEA, Wuhan 430071, China
基金项目:This project is jointly sponsored by the National Natural Science Foundation of China (41574059,41474048), Seismological Science and Technology Spark Program of China Earthquake Administration (XH16028), Scientific Research Fund of Institute of Seismology and Institute of Crustal Dynamics, China Earthquake Administration (IS201726164).
摘    要:Because of the different excitation conditions of the airgun source, there will be subtle differences in airgun signals. Travel time variation of airgun signals often mix into source information which can''t fully reflect the evolution of the medium. This article uses the airgun signals from the Binchuan Transmitting Seismic Station to analyze the airgun signal''s characteristics of phase and correlation. We conducted a comparative analysis of the effects of the pair difference method and the deconvolution method on eliminating the influence of the excitation conditions in travel time variation. The results show that:(1) The pressure pulse and its subsequent wave of airgun source wavelet are less affected by excitation conditions that we can use it to obtain high-precision excitation moments. (2) Deconvolution can improve the correlation of the airgun signal. (3) The pair difference method can''t eliminate the influence of excitation conditions in travel time variation. Deconvolution can reduce excitation condition interference and the influence of the excitation condition in the travel time variation after deconvolution of the vertical signal is significantly reduced.

关 键 词:Airgun  source  Pair  difference  Deconvolution  Travel  time  variation  Correlation
收稿时间:2018/12/26 0:00:00
修稿时间:2019/1/2 0:00:00

Study on the Influence of Airgun Excitation Conditions on Airgun Signals and Travel Time Variation Measurements
XIANG Y,YANG Runhai,WANG Bin,ZHOU Yunyao,LU Yongqing,WU Huan,QI Junwei,PENG Jing.Study on the Influence of Airgun Excitation Conditions on Airgun Signals and Travel Time Variation Measurements[J].Earthquake Research in China,2019,33(2):336-353.
Authors:XIANG Y  YANG Runhai  WANG Bin  ZHOU Yunyao  LU Yongqing  WU Huan  QI Junwei and PENG Jing
Institution:Key Laboratory of Earthquake Geodesy, Institute of Seismology, CEA, Wuhan 430071, China,Yunnan Earthquake Agency, Kunming 650224, China,Yunnan Earthquake Agency, Kunming 650224, China,Key Laboratory of Earthquake Geodesy, Institute of Seismology, CEA, Wuhan 430071, China,Key Laboratory of Earthquake Geodesy, Institute of Seismology, CEA, Wuhan 430071, China,Key Laboratory of Earthquake Geodesy, Institute of Seismology, CEA, Wuhan 430071, China,Key Laboratory of Earthquake Geodesy, Institute of Seismology, CEA, Wuhan 430071, China and Key Laboratory of Earthquake Geodesy, Institute of Seismology, CEA, Wuhan 430071, China
Abstract:Because of the different excitation conditions of the airgun source, there will be subtle differences in airgun signals. Travel time variation of airgun signals often mix into source information which can''t fully reflect the evolution of the medium. This article uses the airgun signals from the Binchuan Transmitting Seismic Station to analyze the airgun signal''s characteristics of phase and correlation. We conducted a comparative analysis of the effects of the pair difference method and the deconvolution method on eliminating the influence of the excitation conditions in travel time variation. The results show that:(1) The pressure pulse and its subsequent wave of airgun source wavelet are less affected by excitation conditions that we can use it to obtain high-precision excitation moments. (2) Deconvolution can improve the correlation of the airgun signal. (3) The pair difference method can''t eliminate the influence of excitation conditions in travel time variation. Deconvolution can reduce excitation condition interference and the influence of the excitation condition in the travel time variation after deconvolution of the vertical signal is significantly reduced.
Keywords:Airgun source  Pair difference  Deconvolution  Travel time variation  Correlation
点击此处可从《中国地震研究》浏览原始摘要信息
点击此处可从《中国地震研究》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号