首页 | 本学科首页   官方微博 | 高级检索  
     检索      

软弱场地地铁车站结构地震反应的数值模拟与模型试验对比分析
引用本文:叶道奎,陈国兴,左熹.软弱场地地铁车站结构地震反应的数值模拟与模型试验对比分析[J].地震学刊,2012(5):528-534.
作者姓名:叶道奎  陈国兴  左熹
作者单位:南京工业大学岩土工程研究所,南京210009
基金项目:国家自然科学基金重大研究计划项目(90715018,90715035); 国家公益性行业科研专项(200808022); 江苏省高校自然科学重大基础研究项目(08KJA560001)资助
摘    要:根据软弱场地土上地铁车站结构大型振动台模型试验结果,以软件ABAQU S为平台,采用记忆型嵌套面黏塑性动力本构模型和动塑性损伤模型,分别模拟土体和车站结构混凝土的动力特性,建立了土-地铁车站结构非线性动力相互作用二维和三维有限元分析模型,对各种试验工况下地基土-地铁车站结构体系的地震反应进行了数值模拟,并与试验结果进行了对比。结果表明:二维、三维数值模拟与振动台模型试验结果基本一致,三维模型可更好地模拟软弱场地与地铁车站结构的动力相互作用及模型结构的动力反应。数值模拟结果和振动台试验结果可相互验证其可靠性。

关 键 词:地铁地下车站结构  地震反应特性  大型振动台模型试验  数值模拟

Comparative Analysis between Numerical Simulation and Model Test on the Seismic Response of Subway Station Structure in Soft Clay
YE Dao-kui,CHEN Guo-xing,ZUO Xi.Comparative Analysis between Numerical Simulation and Model Test on the Seismic Response of Subway Station Structure in Soft Clay[J].Journal of Seismology,2012(5):528-534.
Authors:YE Dao-kui  CHEN Guo-xing  ZUO Xi
Institution:(Institute of Geotechnical Engineering, Naniing University of Technology, Naniing 210009, China)
Abstract:Based on the results of the large-scale shaking table test of subway station structures in soft clay, finite element software ABAQUS was used to establish two-and three-dimensional nonlinear dynamic interaction model for soil-subway station structure system. In the modeling, dynamic visco-plastic memo- rial nested yield surface model was used to describe the dynamic characteristics of soils, and dynamic plas- tic-damage model was used to simulate the dynamic characteristics of tunnel concrete. The seismic re- sponse of soil-subway station structure system under different test conditions was analyzed by the numeri- cal simulation method. Moreover, the numerical simulation results and the shaking table test were com- pared in detail. The results show that the simulation results of the two-and three-dimensional model are basically identical with the shaking table tests. The three-dimensional model is better to simulate the dy- namic interaction of the subway station structure and the soil as well as the dynamic responses of the sta- tion structure in soft clay. The modeling analysis based on software ABAQUS and the shaking table test results are mutually verified.
Keywords:subway station structures  seismic response properties  large-scale shaking table test  numerical simulation
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号