首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Earthquake response of asymmetric building with MR damper
Authors:S D Bharti  S M Dumne  M K Shrimali
Institution:1. Department of Civil Engineering Malaviya National Institute of Technology Jaipur, Jaipur, Rajsthan, 302017, India
2. Govt. Poly. College, Nashik, Maharashtra, India
Abstract:Plan asymmetric buildings are very susceptible to earthquake induced damage due to lateral torsional coupling, and the corners of these systems suffer heavy damage during earthquakes. Therefore, it is important to investigate the seismic behavior of an asymmetric plan building with MR dampers. In this study, the effectiveness of MR damper-based control systems has been investigated for seismic hazard mitigation of a plan asymmetric building. Furthermore, the influence of the building parameters and damper command voltage on the control performance is examined through parametric study. The building parameters chosen are eccentricity ratio and frequency ratio. The results show that the MR damper-based control systems are effective for plan asymmetric systems.
Keywords:torsional coupling  plan asymmetric  MR damper
本文献已被 CNKI 维普 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号