首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Shaking table experimental study of recycled concrete frame-shear wall structures
Authors:Jianwei Zhang  Wanlin Cao  Shaobin Meng  Cheng Yu  Hongying Dong
Institution:1. College of Architecture and Civil Engineering, Beijing University of Technology, Beijing, 100124, China
2. Department of Engineering Technology, University of North Texas, Denton, TX, 76207, USA
Abstract:In this study, four 1/5 scaled shaking table tests were conducted to investigate the seismic performance of recycled concrete frame-shear wall structures with different recycled aggregates replacement rates and concealed bracing detail. The four tested structures included one normal concrete model, one recycled coarse aggregate concrete model, and two recycled coarse and fine aggregate concrete models with or without concealed bracings inside the shear walls. The dynamic characteristics, dynamic response and failure mode of each model were compared and analyzed. Finite element models were also developed and nonlinear time-history response analysis was conducted. The test and analysis results show that the seismic performance of the recycled coarse aggregate concrete frame-shear wall structure is slightly worse than the normal concrete structure. The seismic resistance capacity of the recycled concrete frame-shear wall structure can be greatly improved by setting up concealed bracings inside the walls. With appropriate design, the recycled coarse aggregate concrete frame-shear wall structure and recycled concrete structure with concealed bracings inside the walls can be applied in buildings.
Keywords:recycled concrete  frame-shear wall  concealed bracings  shaking table test  nonlinear time-history response analysis
本文献已被 CNKI 维普 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号