Mitigation of reverse faulting deformation using a soil bentonite wall: Dimensional analysis,parametric study,design implications
Institution:1. Department of Chemical and Materials Engineering, University of Alberta, Edmonton, Alberta T6G 2V4, Canada;2. Department of Mechanical Engineering, University of Alberta, Edmonton, Alberta T6G 2G8, Canada;1. Department of Civil Engineering, National Central University, Taiwan;2. Department of Applied Geology Engineering, National Central University, Taiwan;3. Department of Civil Engineering, National Taiwan University, Taiwan;4. Central Geological Survey, MOEA, Taiwan
Abstract:Recent major seismic events, such as the Chi-Chi (1999) and the Wenchuan (2008) earthquakes occurred in Taiwan and China, have offered a variety of case histories on the performance of structures subjected to reverse faulting–induced deformation. A novel faulting mitigation method has recently been proposed, introducing a soft deformable wall barrier in order to divert the fault rupture away from the structure. This can be materialized by constructing a thick diaphragm-type soil bentonite wall (SBW) between the structure and the fault rupture path. The paper investigates the key parameters in designing such a SBW, aiming to mitigate the fault rupture hazard on shallow foundations. The paper employs a thoroughly validated finite element analysis methodology to explore the efficiency of a weak SBW barrier in protecting slab foundations from large tectonic deformation due to reverse faulting. A dimensional analysis is conducted in order to generalize the validity of the derived conclusions. The dimensionless formulation is then used to conduct a detailed parametric study, exploring the effect of SBW thickness w/H, depth HSBWl/H, and shear strength τsoil/τSBW, as well as the bedrock fault offset h/H, foundation surcharge load q/ρgB, and fault outcrop location s/B. It is shown that the wall thickness, depth, and shear strength should be designed on the basis of the magnitude of the bedrock fault offset, the location of the fault relative to the structure, and the shear strength of the soil. The efficiency of the weak barrier is improved using lower strength and stiffness material compared to the alluvium. A simplified preliminary design methodology is proposed, and presented in the form of a flowchart.
Keywords:Soil bentonite wall  Near fault ground displacement  Reverse fault  Mitigation  Shallow foundation
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号