集宁地电观测系统故障检查及处理
引用本文:徐锡泉,张国清,包文超,赵星,苏亚梅,张小艳,樊莎.集宁地电观测系统故障检查及处理[J].地震地磁观测与研究,2018,39(5):165-171.
作者姓名:徐锡泉  张国清  包文超  赵星  苏亚梅  张小艳  樊莎
作者单位:1.中国内蒙古自治区 010010 呼和浩特基准地震台;2.中国内蒙古自治区 026000 锡林浩特地震台;3.中国呼和浩特 010010 内蒙古自治区地震局监测预报中心
摘    要:对集宁2017年4月1日-5月31日地电阻率原始观测数据曲线常规分析发现,NS、EW测道数值差异明显,采用电测深曲线进行对比分析,发现2测道电阻率数值基本一致。在同场范围内,地电阻率与电测深曲线应同步变化。对集宁地电阻率布极区、观测环境、观测系统、装置系统进行系列检查、测试,发现NS测道导线线芯与导线铠导通,导线铠与避雷箱箱体接触导致线路漏电,造成数值出现误差。通过对外线路以及电极引线等进行优化改造,集宁地电阻率观测数据恢复正常。

关 键 词:地电阻率  装置系统  故障  漏电

Fault inspection and treatment of Jining geoelectric observation system
Xu Xiquan,Zhang Guoqing,Bao Wenchao,Zhao Xing,Su Yamei,Zhang Xiaoyan,Fan Sha.Fault inspection and treatment of Jining geoelectric observation system[J].Seismological and Geomagnetic Observation and Research,2018,39(5):165-171.
Authors:Xu Xiquan  Zhang Guoqing  Bao Wenchao  Zhao Xing  Su Yamei  Zhang Xiaoyan  Fan Sha
Institution:1.Hohhot Fiducial Seismic Station, Inner Mongolia Autonomous Region 010010, China;2.Xilinhot Seismic Station, Inner Mongolia Autonomous Region 026000, China;3.Monitoring And Forecasting Center, Earthquake Agency of Inner Mongolia Autonomous Region, Hohhot 010010, China
Abstract:The conventional analysis of the original observation data curve of ground resistivity from April 1, to May 31, 2017 found that the values of NS and EW were significantly different, and the comparison analysis was conducted by using the electric sounding curve. It was found that the values of the resistivity of the two measured channels were basically consistent. A series of checks and tests were carried out on the resistivity field, observation environment, observation system and device system in Jining, and it was found that the wire core and armor of NS component wire was short out and wire armor connects with lightning protection box, which led to leakage of power, resulting in numerical error. The observation system was optimized and improved, and then the resistivity observation data in Jining area was restored to normal.
Keywords:earth resistivity  device system  fault  the leakage