首页 | 本学科首页   官方微博 | 高级检索  
     检索      

GTS探空仪碳湿敏元件性能测试数据分析及相对湿度订正
引用本文:徐文静,郭亚田,黄炳勋,顾善荣.GTS探空仪碳湿敏元件性能测试数据分析及相对湿度订正[J].气象科技,2007,35(3):423-428.
作者姓名:徐文静  郭亚田  黄炳勋  顾善荣
作者单位:1. 中国气象科学研究院,北京,100081
2. 中国气象局大气探测技术中心,北京,100081
3. 上海无线电23厂,上海,200090
基金项目:中国气象科学院院长基金
摘    要:碳湿敏元件受温度影响明显,造成相对湿度探空数据测量的误差。利用温湿控制设备对该元件进行静态试验,测试不同温度对元件感湿特性的影响。通过对试验数据分析计算得到元件的相对湿度温度项订正数据,以及相对湿度的温度项订正拟合公式,可以有效订正由温度引起的相对湿度探空数据误差。对实际相对湿度探空数据资料订正效果的对比分析表明,经过温度项订正后的相对湿度探空数据,不但其准确度得到了提高,而且清楚地体现出在订正之前所不能体现的高空大气相对湿度在低湿段的变化细节。

关 键 词:碳湿敏元件  相对湿度  探空数据  温度项订正
收稿时间:2006/1/26 0:00:00
修稿时间:2006-01-262006-04-04

Analysis of GTS Radiosonde Humidity Sensor Testing Data and Correction of Upper Air Relative Humidity Radiosonde Data
Xu Wenjing,Guo Yatian,Huang Bingxun and Gu Shanrong.Analysis of GTS Radiosonde Humidity Sensor Testing Data and Correction of Upper Air Relative Humidity Radiosonde Data[J].Meteorological Science and Technology,2007,35(3):423-428.
Authors:Xu Wenjing  Guo Yatian  Huang Bingxun and Gu Shanrong
Institution:1. Chinese Academy of Meteorological Sciences, Beijing 100081 ; 2. Atmosphere Observation Technology Center, CMA, Beijing 100081 ; 3. Shanghai No. 23 Radio Factory, Shanghai 200090
Abstract:The carbon humidity sensor's resistance is significantly influenced by temperature,resulting in upper-air relative humidity sounding data errors.Through static tests on the sensors in the temperature-humidity controlled chamber,the testing of the resistance changes was conducted under different temperatures. Based on the analysis and calculation on these lab data,the correction data of relative humidity and temperature were obtained,and the relative humidity correction equation was established,which can effectively correct the errors caused by temperature correspondingly.The comparison and analysis of correction on real upper-air relative humidity sounding data indicates that not only the accuracy of relative humidity data is improved after correction,but also the detailed variations in relative humidity at the upper atmosphere during the lower humidity period can be clearly manifested,which cannot be seen before correction.
Keywords:carbon humidity sensor  relative humidity  upper-air radiosonde data
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《气象科技》浏览原始摘要信息
点击此处可从《气象科技》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号