首页 | 本学科首页   官方微博 | 高级检索  
     检索      

黑龙江省直击雷防护效率空间分布特征
引用本文:袁湘玲,马虹旭,周倩,穆森,尤少杰.黑龙江省直击雷防护效率空间分布特征[J].气象与环境学报,2020,36(1):96-101.
作者姓名:袁湘玲  马虹旭  周倩  穆森  尤少杰
作者单位:1. 齐齐哈尔市气象局, 黑龙江 齐齐哈尔 1610062. 辽宁省防雷技术服务中心, 辽宁 沈阳 1101663. 天津市防雷技术中心, 天津 340074
基金项目:黑龙江省地方标准项目“雷电易发区及雷电灾害风险等级划分”(2018)资助
摘    要:基于2008—2016年黑龙江省ADTD闪电定位数据,利用反距离权重插值法和Pearson相关分析法,研究了地闪密度、地闪强度、绕击率和反击率的空间分布特征,分析了黑龙江省不同防雷类别的直击雷防护效率。结果表明:地闪密度和地闪强度的空间分布呈负相关,相关系数为-0.608;绕击率和地闪密度呈正相关,与地闪强度呈低度负相关;反击率地闪密度呈低度负相关,与地闪强度均呈显著正相关。黑龙江省不同防雷类别直击雷防护保护范围内的绕击率分别为0.04%、0.71%和4.59%,即第一、二、三类防雷类别直击雷防护效率分别为99.96%、99.29%和95.41%。按照《建筑物防雷设计规范》计算第一、二、三类防雷建筑物的安全距离时,将会分别存在3.16%、4.64%和7.32%左右发生反击的风险。

关 键 词:直击雷  防护效率  绕击率  反击率  
收稿时间:2019-04-30

Spatial characteristics of the protection efficiency of the direct lightning in Heilongjiang province
YUAN Xiang-ling,MA Hong-xu,ZHOU Qian,MU Sen,YOU Shao-jie.Spatial characteristics of the protection efficiency of the direct lightning in Heilongjiang province[J].Journal of Meteorology and Environment,2020,36(1):96-101.
Authors:YUAN Xiang-ling  MA Hong-xu  ZHOU Qian  MU Sen  YOU Shao-jie
Institution:1. Qiqihar Meteorological Service, Qiqihar 161006, China2. Service Center of Lightning Protection Technology in Liaoning Province, Shenyang 110166, China3. Tianjin Lighting Protection Center, Tianjin 300074, China
Abstract:Based on lightning location data in Heilongjiang province,the spatial distribution characteristics of ground flash density,ground flash intensity,shielding failure rate and counterattack rate were studied and the protection efficiencies of the different types of direct lightning were analyzed by using IDW and Pearson correlation analysis method.The results show that the spatial distributions of ground flash density and intensity are negatively correlated and the correlation coefficient is-0.608.The shielding failure rate is positively correlated with the ground flash density but is negatively correlated with the ground flash intensity.The counter-attack rate is negatively correlated with the ground flash density and is positively correlated with the ground flash intensity.In addition,the shielding failure rates of the first,second and third types of lightning protection buildings in Heilongjiang province are 0.04%,0.71%,and 4.59%,meaning that the lightning protection efficiencies of three types of direct lightning protection buildings are 99.96%,99.29%,and 95.41%,respectively.Besides,when the safety distances of the lightning protection buildings are calculated according to the design norm for protection of structures against lightning,the risk of counterattack of the first,second and third types of lightning protection buildings will reach 3.16%4.64%and 7.32%,respectively.
Keywords:Direct lightning  Protection efficiency  Shielding failure rate  Counterattack rate
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《气象与环境学报》浏览原始摘要信息
点击此处可从《气象与环境学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏