An experimental facility for testing loaded structures in a high hydrostatic pressure environment and an application to axially loaded columns
Authors:Richard P Shaw  John Sezna
Institution:State University of New York at Buffalo, USA
Abstract:An experimental facility is described for the testing of structures under a combined axial load and hydrostatic pressure load. This facility was used to determine the effects of hydrostatic pressure (up to 6000 psi) on the load-carrying capacity of slender metal columns. There appeared to be no significant effect in this case.