首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Temperature coefficient of seawater pH as a function of temperature,pH, DIC and salinity
作者姓名:Yubin  Hu
作者单位:Institute of Marine Science and Technology, Shandong University
基金项目:The National Natural Science Foundation of China under contract No. 41806094;
摘    要:pH is a measure of the hydrogen ion activity in a solution, which is a function of temperature. Under normal seawater conditions, it is well constrained. Nowadays, with an increasing interest in complex environments(e.g.,sea ice), a better understanding of the temperature change on pH under extreme conditions is needed. The objective of this paper was to investigate the temperature coefficient of the seawater pH(?pH/?T) over a wide range of temperature, pH, dissolved inorganic carbon(DIC) and sa...


Temperature coefficient of seawater pH as a function of temperature,pH, DIC and salinity
Yubin Hu.Temperature coefficient of seawater pH as a function of temperature,pH, DIC and salinity[J].Acta Oceanologica Sinica,2022,41(6):114-118.
Authors:Yubin Hu
Institution:Institute of Marine Science and Technology, Shandong University, Qingdao 266237, China
Abstract:pH is a measure of the hydrogen ion activity in a solution, which is a function of temperature. Under normal seawater conditions, it is well constrained. Nowadays, with an increasing interest in complex environments (e.g., sea ice), a better understanding of the temperature change on pH under extreme conditions is needed. The objective of this paper was to investigate the temperature coefficient of the seawater pH (?pH/?T) over a wide range of temperature, pH, dissolved inorganic carbon (DIC) and salinity by a method of continuous pH measurement with the temperature change, and to verify the application of CO2SYS for pH conversion under extreme conditions (on the National Bureau of Standards (NBS) scale and the total proton scale). Both experimental results and CO2SYS calculations showed that ?pH/?T was slightly affected by temperature over the range of 0°C to 40°C and by pH (at 25°C) from 7.8 to 8.5. However, when pH was out of this range, ?pH/?T varied greatly with pH value. According to the experimental results, changes in DIC from 1 mmol/kg to 5 mmol/kg and salinity from 20 to 105 had no significant effect on ?pH/?T. CO2SYS calculations showed a slight increase in ?pH/?T with DIC on both the NBS scale and the total proton scale; and underestimated ?pH/?T at high salinity (i.e., beyond the oceanographic range) on the NBS scale. Nevertheless, CO2SYS is still suitable for pH conversion even under extreme conditions by simply setting the input values of DIC and salinity in CO2SYS within the oceanographic range (e.g., DIC=2 mmol/kg and S=35).
Keywords:temperature coefficient  pH measurement  CO2SYS  sea ice  ocean acidification
点击此处可从《海洋学报(英文版)》浏览原始摘要信息
点击此处可从《海洋学报(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号