首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Colorimetric determination of nanomolar concentrations of silicate in natural waters after liquid-liquid extraction using methyl isobutyl ketone
作者姓名:REN Jingling  MI Tiezhu  DOU Weiwei  LIU Sumei  ZHANG Jing
作者单位:REN Jingling(Key Laboratory of Marine Chemistry Theory and Technology of Ministry of Education,Ocean University of China,Qingdao 266100,China) ; MI Tiezhu(College of Environmental Science and Engineering,Ocean University of China,Qingdao 266100,China) ; DOU Weiwei(Key Laboratory of Marine Chemistry Theory and Technology of Ministry of Education,Ocean University of China,Qingdao 266100,China) ; LIU Sumei(Key Laboratory of Marine Chemistry Theory and Technology of Ministry of Education,Ocean University of China,Qingdao 266100,China) ; ZHANG Jing(Key Laboratory of Marine Chemistry Theory and Technology of Ministry of Education,Ocean University of China,Qingdao 266100,China;State Key Laboratory of Estuarine and Coastal Research,East China Normal University,Shanghai 200062,China) ;
基金项目:The National Science Foundation of China under contract No.40606028 and the Special Fund from the National Key Basic Research Program of China under contract No.2006CB400601.
摘    要:A sensitive solvent extraction method for the determination of nonamolar concentrations of silicate in natural waters is developed. According to the traditional aqueous silicate method, silicomolybdenum blue formed by the reaction between silicate and ammoni- um molydate and reduced by metol-sulfite reagent is extracted by methyl isobutyl ketone. The absorbance can be enhanced substantially up to 10-folds. The detection limit of silicate is 8 nmol/dm^3 , which is one tenth smaller than the traditional method, with the precision of 4.0% at a silicate level of 50 nmol/dm^3 and 3.2% at a silicate level of 6 μmol/dm^3. Comparing the calibration curves in the distilled water and seawater, it can be seen that the salt effect also exists in the extraction method. However, the salt effect is a linear function of the salinity and can be corrected by simple calibration. The proposed method is successfully applied to the determination of silicate in natural waters. Natural concentrations of arsenate, arsenite and phosphate cause negligible interference.

关 键 词:硅酸盐  比色测定  液-液萃取  甲基异丁基酮
收稿时间:2006/7/12 0:00:00
修稿时间:2007/1/12 0:00:00

Colorimetric determination of nanomolar concentrations of silicate in natural waters after liquid-liquid extraction using methyl isobutyl ketone
REN Jingling,MI Tiezhu,DOU Weiwei,LIU Sumei,ZHANG Jing.Colorimetric determination of nanomolar concentrations of silicate in natural waters after liquid-liquid extraction using methyl isobutyl ketone[J].Acta Oceanologica Sinica,2008,27(1):137-146.
Authors:REN Jingling  MI Tiezhu  DOU Weiwei  LIU Sumei and ZHANG Jing
Institution:1.Key Laboratory of Marine Chemistry Theory and Technology of Ministry of Education, Ocean University of China, Qingdao 266100, China2.College of Environmental Science and Engineering, Ocean University of China, Qingdao 266100, China3.Key Laboratory of Marine Chemistry Theory and Technology of Ministry of Education, Ocean University of China, Qingdao 266100, China;State Key Laboratory of Estuarine and Coastal Research, East China Normal University, Shanghai 200062, China
Abstract:A sensitive solvent extraction method for the determination of nonamolar concentrations of silicate in natural waters is developed. According to the traditional aqueous silicate method,silicomolybdenum blue formed by the reaction between silicate and ammoni- um molydate and reduced by metel-sulfite reagent is extracted by methyl isobutyl ketone.The abserbance can be enhanced sub- stantially up to 10-folds.The detection limit of silicate is 8 nmoL/dm3,which is one tenth smaller than the traditional method, with the precision of 4.0% at a silicate level of 50 nmol/dm3 and 3.2% at a silicate level of 6 μmol/dm3.Comparing the calibra- tion curves in the distilled water and seawater,it can be seen that the salt effect also exists in the extraction method.However,the salt effect is a linear function of the salinity and can be corrected by simple calibration.The proposed method is successfully ap- plied to the determination of silicate in natural waters.Natural concentrations of arsenate,arsenite and phosphate cause negligible interference.
Keywords:silicate  colorimetric determination  liquid-liquid extraction  methyl isebutyl ketone
本文献已被 维普 万方数据 等数据库收录!
点击此处可从《海洋学报(英文版)》浏览原始摘要信息
点击此处可从《海洋学报(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏