Measurement of dissolved oxygen using optodes in a FerryBox system
Authors:DJ Hydes  MC Hartman  J Kaiser  JM Campbell
Institution:aNational Oceanography Centre, Empress Dock, Southampton S014 3ZH, UK;bSchool of Environmental Sciences, University of East Anglia, Norwich NR4 7TJ, UK
Abstract:Optode sensors can provide detailed information on concentrations of dissolved oxygen, which in turn may be used to quantify variations in net primary productivity. Throughout 2005 and 2006 the performance of commercially available oxygen optodes was examined, one in each year. The optode was part of an autonomous measurement system (FerryBox) on a ferry operating between Portsmouth (UK) and Bilbao (Spain). On crossings during which water samples were collected manually, the optode outputs were compared to measurements of dissolved oxygen made by Winkler titrations. The optodes maintained good stability with no evidence of instrumental drift during the course of a year. Over the observed concentration range (230–330 mM m−3) the optode data were approximately 2% low in both years. By fitting the optode data to the Winkler data the median difference between the optode and Winkler measurements is reduced to less than 1 mM m−3 (0.3%) in both years. The most appropriate calibration factor for 2005 was corrected O2 = Optode O2 × 1.018 and for 2006 the corresponding equation is corrected O2 = Optode O2 × 0.884 + 36.8. The standard deviation (95%) of the difference between the individual Winkler measurements was 5 mM m−3 and 3 mM m−3 in 2005 and 2006 respectively.Calculation of the oxygen saturation anomaly is required for calculation of the air sea exchange of oxygen and net biological production. This calculation requires the use of both salinity and temperature data. Salinity is measured to better than 0.1 so the corresponding error in anomaly is less than 0.2 mM m−3. Distortion of the temperature data is present due to warming of the water pumped to the optode. In winter this warming at the optode may be as great as 0.4 °C. The difference in the pumped water temperature can be corrected for by reference to other measurements of sea surface temperature reducing the error to less than 1 mM m−3.
Keywords:FerryBox  monitoring  seawater  dissolved oxygen  optode  Winkler titration  gas exchange  productivity  English Channel  Bay of Biscay  autonomous measurement
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号