摘    要:重晶石经Na2CO3熔融,水浸取,过滤。沉淀经HCl溶解后,用电感耦合等离子体发射光谱法同时测定主成分BaSO4和次量成分Fe2O3以及滤液中的SiO2,结果与部颁标准方法符合。方法精密度好,主量组分BaSO4测定的RSD(n=6)为0.24%,次量组分Fe2O3和SiO2的RSD(n=6)分别是3.69%和1.45%。

关 键 词:电感耦合等离子体发射光谱  重晶石  硫酸钡  三氧化二铁  二氧化硅
修稿时间:1997-07-02

Simultaneous Determination of Major and Minor Components in Barite Samples by ICP-AES
Yang Dejun,Zhao Yongkui,Lu Yaqin,Chen Liping.Simultaneous Determination of Major and Minor Components in Barite Samples by ICP-AES[J].Rock and Mineral Analysis,1998,17(4):317-318.
Authors:Yang Dejun  Zhao Yongkui  Lu Yaqin  Chen Liping
Abstract:Barite sample was fused with Na 2CO 3 and then converted into sample solution after water leaching, filtering, and precipitate was resolved by HCl. The major component of BaSO 4 and minor component of Fe 2O 3 in sample solution and SiO 2 in filter liquor were determined by ICP AES. The results were in agreement with that provided by the standard method. The precision for major component of BaSO 4 was 0.24% RSD ( n =6) and minor components of Fe 2O 3 and SiO 2 were 3.69% and 1.45% RSD ( n =6) respectively.