Iron Distribution in Size‐Resolved Aerosols Generated by UV‐Femtosecond Laser Ablation: Influence of Cell Geometry and Implications for In Situ Isotopic Determination by LA‐MC‐ICP‐MS
Authors:Francois‐Xavier d'Abzac  Andrew D Czaja  Brian L Beard  James J Schauer  Clark M Johnson
Institution:1. Department of Geoscience, University of Wisconsin, , Madison, WI, 53706 USA;2. NASA Astrobiology Institute, University of Wisconsin, , Madison, WI, USA;3. Departments of Geology and Chemistry, University of Cincinnati, , Cincinnati, OH, 45221 USA;4. Environmental Chemistry and Technology Program, University of Wisconsin, , Madison, WI, 53706‐1484 USA
Abstract:The influence of ablation cell geometry (Frames single‐ and HelEx two‐volume cells) and laser wavelength (198 and 266 nm) on aerosols produced by femtosecond laser ablation (fs‐LA) were evaluated. Morphologies, iron mass distribution (IMD) and 56Fe/54Fe ratios of particles generated from magnetite, pyrite, haematite and siderite were studied. The following two morphologies were identified: spherules (10–200 nm) and agglomerates (5–10 nm). Similarity in IMD and ablation rate at 198 and 266 nm indicates similar ablation mechanisms. 56Fe/54Fe ratios increased with aerodynamic particle size as a result of kinetic fractionation during laser plasma plume expansion, cooling and aerosol condensation. The HelEx cell produces smaller particles with a larger range of 56Fe/54Fe ratios (1.85‰) than particles from the Frames cell (1.16‰), but the bulk aerosol matches the bulk substrate for both cells, demonstrating stoichiometric fs‐LA sampling. IMD differences are the result of faster wash out of the HelEx cell allowing less time for agglomeration of small, low‐δ 56Fe particles with larger, high‐δ 56Fe particles in the cell. Even with a shorter ablation time, half the total Fe ion intensity, and half the ablation volume, the HelEx cell produced Fe isotope determinations for magnetite that were as precise as the Frames cell, even when the latter included an aerosol‐homogenising mixing chamber. The HelEx cell delivered a more constant stream of small particles to the ICP, producing a more stable Fe ion signal (0.7% vs. 1.5% RSE for 56Fe in a forty‐cycle single analysis), constant instrumental mass bias and thus a more precise measurement.
Keywords:femtosecond laser ablation  aerosols  isotopes  agglomeration  residence time  ablation laser femtoseconde    rosols  isotopes  l'agglomé  ration  temps de ré  sidence
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号