首页 | 本学科首页   官方微博 | 高级检索  
     检索      

炸药触地爆炸后核电站安全壳基底振动响应分析
引用本文:申祖武,刘国强,王天运,刘水江.炸药触地爆炸后核电站安全壳基底振动响应分析[J].岩土力学,2009,30(8):2540-2544.
作者姓名:申祖武  刘国强  王天运  刘水江
作者单位:1. 武汉理工大学,土木工程与建筑学院,武汉,430070
2. 武汉理工大学,土木工程与建筑学院,武汉,430070;总参工程兵科研三所,洛阳,471023
3. 总参工程兵科研三所,洛阳,471023
摘    要:现代战争或恐怖活动中,核电站很可能受到精确制导炸弹的攻击.运用有限元软件LS-DYNA3D,以5 000 kg等效TNT当量的装药在安全壳100 m外触地爆炸为例,将装药爆炸、土中传播和结构构成有限元分析体系,对安全壳基底的振动响应进行了分析.结果表明,安全壳基底和壳体的压力呈环状分布,在基底和壳体的连接处有明显的应力集中;等效应力-时程曲线和径向应力-时程曲线显示,壳体的最大等效应力为35 kPa、最大径向应力为32 kPa,均在安全范围.在给定的条件下,基底和壳体的响应值远未超出设计值,核电站的运行安全可靠.

关 键 词:爆炸冲击波  安全壳基底  振动响应  有限元分析
收稿时间:2009-01-05

Analysis of vibration response of containment foundation in nuclear power station after munitions bombing
SHEN Zu-wu,LIU Guo-qiang,WANG Tian-yun,LIU Shui-jiang.Analysis of vibration response of containment foundation in nuclear power station after munitions bombing[J].Rock and Soil Mechanics,2009,30(8):2540-2544.
Authors:SHEN Zu-wu  LIU Guo-qiang  WANG Tian-yun  LIU Shui-jiang
Institution:1. College of Civil Engineering and Architecture, Wuhan University of Technology, Wuhan 430070, China; 2. The Third Research Institute of the Corps of Engineering, General Staff of PLA, Luoyang 471023, China
Abstract:In the modern war or terrorism, nuclear power station may greatly have been attacked by pinpoint general bomb. Using finite element software LS-DYNA3D, taking 5000kg munitions equivalent to TNT bombing 100m away from the nuclear power station as an example, while munitions explosion、propagation among soil together with structure constitution are regarded as a finite element analysis system, the vibration response of the containment foundation is analyzed. The result indicate that the pressure of foundation and containment is dispersed as ring, and the joint show stress focus. The time-history curve for Von-Mises stress and the time-history curve for radial stress show that the mix Von-Mises stress of the containment is 35 Kpa and the mix radial stress of the containment is 32 Kpa. Under the given condition, the response value of the foundation and containment is far smaller than the design value, the nuclear power station is safe and reliable。
Keywords:blast shock wave  containment foundation  vibration response  finite element analysis  
本文献已被 万方数据 等数据库收录!
点击此处可从《岩土力学》浏览原始摘要信息
点击此处可从《岩土力学》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号