首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The inelastic earthquake response of eccentric, multistorey, frame‐type, reinforced concrete buildings is investigated using three‐ and five‐storey models, subjected to a set of 10, two‐component, semi‐artificial motions, generated to match the design spectrum. Buildings designed according to the EC8 as well as the UBC‐97 code were included in the investigation. It is found that contrary to what the simplified one‐storey, typical, shear‐beam models predict, the so‐called ‘flexible’ side frames exhibit higher ductility demands than the ‘stiff’ side frames. The substantial differences in such demands between the two sides suggest a need for reassessment of the pertinent code provisions. This investigation constitutes one of the first attempts to study the problem of inelastic torsion by means of realistic, multistorey inelastic building models. Additional studies with similar or even more refined idealizations will certainly be required to arrive at definite results and recommendations for possible code revisions. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

2.
The inelastic seismic torsional response of simple structures is examined by means of shear‐beam type models as well as with plastic hinge idealization of one‐story buildings. Using mean values of ductility factors, obtained for groups of ten earthquake motions, as the basic index of post‐elastic response, the following topics are examined with the shear‐beam type model: mass eccentric versus stiffness eccentric systems, effects of different types of motions and effects of double eccentricities. Subsequently, comparisons are made with results obtained using a more realistic, plastic hinge type model of single‐story reinforced concrete frame buildings designed according to a modern Code. The consequences of designing for different levels of accidental eccentricity are also examined for the aforementioned frame buildings. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

3.
To deal with earthquake-induced torsion in buildings due to some uncertain factors, difficult to account for directly in design, modern codes have introduced the so-called accidental design eccentricity (ADE). This provision has been based primarily on elastic investigations with special classes of multi-story buildings or with simplified, one-story inelastic models. In the present paper, the effectiveness of this provision is investigated using inelastic models, both of the typical one-story, 3-DOF type, and the more sophisticated MDOF, frame idealizations of the plastic hinge type. One, three and five story, realistic, frame buildings with different natural eccentricities were designed for different ADEs, including those specified by the EC8 and IBC codes. The evaluation is made using mean peak ductility factors of the edge frames as measures of their inelastic response, obtained from dynamic analyses for ten pairs of semi-artificial earthquake motions. The simplified models indicate that the accidental design eccentricity is very effective in reducing ductility demands, especially for very stiff systems. However, this is not confirmed by the more accurate and detailed plastic hinge building models, which show that designs accounting for accidental eccentricity do not exhibit any substantial reduction or better distribution of ductility demands, compared to designs in which accidental eccentricity has been entirely ignored. These findings suggest that the ADE provisions in codes, especially the more complicated ones as in the IBC, should be re-examined, by weighting their importance against the additional computational work they impose on designers. In the cases examined herein this importance can be characterized as marginal. Obviously additional studies are required, to include more building types and earthquake motions, in order to arrive at firm conclusions and recommendations for code modifications.  相似文献   

4.
The use of collision shear walls (bumper‐type), acting transversely to the side subject to pounding, as a measure to minimize damage of reinforced concrete buildings in contact, is investigated using 5‐story building models. The buildings were designed according to the Greek anti‐seismic and reinforced concrete design codes. Owing to story height differences potential pounding in case of an earthquake will occur between floor slabs, a case specifically chosen because this is when pounding can turn out to be catastrophic. The investigation is carried out using nonlinear dynamic analyses for a real earthquake motion and also a simplified solution for a triangular dynamic force of short duration, comparable to the forces caused by pounding. For such analyses, nonlinear, prismatic beam–column elements are used and the effects of pounding are expressed in terms of changes in rotational ductility factors of the building elements. The local effects of pounding on the collision shear walls are investigated using a detailed nonlinear finite element model of the shear walls and results are expressed in terms of induced stresses. It is found that pounding will cause instantaneous acceleration pulses in the colliding buildings and will somewhat increase ductility demands in the members of the top floor, but all within tolerable limits. At the same time the collision walls will suffer repairable local damage at the points of contact, but will effectively protect both buildings from collapse, which could occur if columns were in the place of the walls. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

5.
The mid‐story isolation design method is recently gaining popularity for the seismic protective design of buildings located in the areas of high population. In a mid‐story isolated building, the isolation system is incorporated into the mid‐story rather than the base of the building. In this paper, the dynamic characteristics and seismic responses of mid‐story isolated buildings are investigated using a simplified three‐lumped‐mass structural model for which equivalent linear properties are formulated. From the parametric study, it is found that the nominal frequencies of the superstructure and the substructure, respectively, above and below the isolation system have significant influences on the isolation frequency and equivalent damping ratio of a mid‐story isolated building. Moreover, the mass and stiffness of the substructure are of greater significance than the superstructure in affecting the dynamic characteristics of the isolated building. Besides, based on the response spectrum analysis, it is noted that the higher mode responses may contribute significantly to the story shear force of the substructure. Consequently, the equivalent lateral force procedure of design codes should carefully include the effects of higher modes. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
The effects of Rayleigh damping model on the engineering demand parameters of two steel moment‐resisting frame buildings were evaluated. Two‐dimensional models of the buildings were created and response history analysis were conducted for three different hazard levels. The response history analysis results indicate that mass‐proportional damping leads to high damping forces compared with restoring forces and may lead to overestimation of floor acceleration demands for both buildings. Stiffness‐proportional damping, on the other hand, is observed to suppress the higher‐mode effects in the nine‐story building resulting in lower story drift demands in the upper floors compared with other damping models. Rayleigh damping models, which combine mass‐proportional and stiffness‐proportional components, that are anchored at reduced modal frequencies lead to reasonable damping forces and floor acceleration demands for both buildings and does not suppress higher‐mode effects in the nine‐story building. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

7.
Concentrated plasticity (CP) models are frequently used in static and dynamic building analysis and have been implemented in available commercial software. This investigation deals with three different CP‐models, a simplified macroelement model (SEM) for a complete building story, a frame element with elasto‐plastic interaction hinges (PH), and a frame element with fiber hinges (FB). The objectives of this work are to evaluate the quality of the earthquake responses predicted by these models and to identify important aspects of their implementation and limitations for their use in dynamic analysis. The three elements are tested in a single‐story asymmetric plan building and in a three‐story steel building. Results show that base shear and global response values are usually computed with better accuracy than interstory deformations and local responses. Besides, the main limitation of elasto‐plastic CP models is to control the displacement offsets that result from perfect elasto‐plastic behavior. On the other hand, calibration of the SEM‐model shows that global responses in steel structures may be computed within 20% error in the mean at a computational cost two orders of magnitude smaller than that of the other CP elements considered. However, the three element models considered lead to increasing levels of accuracy in the dynamic response and their use depends on the refinement of the analysis performed. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

8.
The self‐centering energy dissipative (SCED) brace is a new steel bracing member that provides both damping to the structure and a re‐centering capability. The goal of this study was to confirm the behavior of SCED braces within complete structural systems and to confirm the ability to model these systems with both a state‐of‐the‐art computer model as well as a simplified model that would be useful to practicing engineers. To these ends, a three‐story SCED‐braced frame was designed and constructed for testing on a shake table. Two concurrent computer models of the entire frame were constructed: one using the opensees nonlinear dynamic modeling software, and a simplified model using the commercial structural analysis software sap2000 . The frame specimen was subjected to 12 significant earthquakes without any adjustment or modification between the tests. The SCED braces prevented residual drifts in the frame, as designed, and did not show any significant degradation due to wear. Both numerical models were able to predict the drifts, story shears, and column forces well. Peak story accelerations were overestimated in the models; this effect was found to be caused by the absence of transitions at stiffness changes in the hysteretic model of the braces. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
In this study, the torsional response of buildings with peripheral steel‐braced frame lateral systems is evaluated. A three‐dimensional model of a three story braced frame with various levels of eccentricity is created and the effects of torsion on the seismic response is assessed for four hazard levels. The response history analysis results indicate that, unlike frame structures, the torsional amplifications in the inelastic systems exceed those of corresponding elastic systems and tend to increase with an increase in the level of inelasticity. The ability of two simplified procedures, elastic response spectrum analysis and pushover analysis, to capture the torsional amplifications in steel‐braced frames is evaluated. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

10.
Shaking table test results from a one‐story, two‐bay reinforced concrete frame sustaining shear and axial failures are compared with nonlinear dynamic analyses using models developed for the collapse assessment of older reinforced concrete buildings. The models provided reasonable estimates of the overall frame response and lateral strength degradation; however, the measured drifts were underestimated by the models. Selected model parameters were varied to investigate the sensitivity of the calculated response to changes in the drift at shear failure, rate of shear strength degradation, and drift at axial failure. For the selected ground motion, the drift at shear failure and rate of shear strength degradation did not have a significant impact on the calculated peak drift. By incorporating shear and axial‐load failure models, the analytical model is shown to be capable of predicting the axial‐load failure for a hypothetical frame with three nonductile columns. Improvements are needed in drift demand estimates from nonlinear dynamic analysis if such analyses are to be used in displacement‐based performance assessments. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

11.
Non‐ductile reinforced concrete buildings represent a prevalent construction type found in many parts of the world. Due to the seismic vulnerability of such buildings, in areas of high seismic activity non‐ductile reinforced concrete buildings pose a significant threat to the safety of the occupants and damage to such structures can result in large financial losses. This paper introduces advanced analytical models that can be used to simulate the nonlinear dynamic response of these structural systems, including collapse. The state‐of‐the‐art loss simulation procedure developed for new buildings is extended to estimate the expected losses of existing non‐ductile concrete buildings considering their vulnerability to collapse. Three criteria for collapse, namely first component failure, side‐sway collapse, and gravity‐load collapse, are considered in determining the probability of collapse and the assessment of financial losses. A detailed example is presented using a seven‐story non‐ductile reinforced concrete frame building located in the Los Angeles, California. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

12.
A damage detection algorithm of structural health monitoring systems for base‐isolated buildings is proposed. The algorithm consists of the multiple‐input multiple‐output subspace identification method and the complex modal analysis. The algorithm is applicable to linear and non‐linear systems. The story stiffness and damping as damage indices of a shear structure are identified by the algorithm. The algorithm is further tuned for base‐isolated buildings considering their unique dynamic characteristics by simplifying the systems to single‐degree‐of‐freedom systems. The isolation layer and the superstructure of a base‐isolated building are treated as separate substructures as they are distinctly different in their dynamic properties. The effectiveness of the algorithm is evaluated through the numerical analysis and experiment. Finally, the algorithm is applied to the existing 7‐story base‐isolated building that is equipped with an Internet‐based monitoring system. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

13.
A summary of the development of a new coupled shear‐bending model for analysis of stacked wood shear walls and multi‐story wood‐frame buildings is presented in this paper. The model focuses on dynamic response of light‐frame wood structures under seismic excitation. The formulation is intended to provide a more versatile option than present pure shear models in that the new model is capable of accurately capturing the overall lateral response of each story diaphragm and separates the inter‐story shear deformation and the deformation associated with rotation of the diaphragm due to rod elongation, which is an analogue to the bending deformation in an Euler–Bernoulli beam model. Modeling the coupling of bending and shear deformation is shown to provide more accurate representation of stacked shear wall system behavior than a pure shear model, particularly for the upper stories in the assembly. The formulation is coupled with the newly developed evolutionary parameter hysteretic model for wood shear walls. Existing data from a shake table test of an isolated three‐story wood shear wall were used to verify the accuracy of the model prediction. The numerical results agreed very well with shake table test measurements. The influence of a continuous rod hold‐down system on the dynamic behavior of the three‐story stacked wood shear wall was also successfully simulated. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
This paper presents an analytical study evaluating the influence of ground motion duration on structural damage of 3‐story, 9‐story, and 20‐story SAC steel moment resisting frame buildings designed for downtown Seattle, WA, USA, using pre‐Northridge codes. Two‐dimensional nonlinear finite element models of the buildings are used to estimate the damage induced by the ground motions. A set of 44 ground motions is used to study the combined effect of spectral acceleration and ground motion significant duration on drift and damage measures. In addition, 10 spectrally equivalent short‐duration shallow crustal ground motions and long‐duration subduction zone records are selected to isolate duration effect and assess its effect on the response. For each ground motion pair, incremental dynamic analyses are performed at at least 20 intensity levels and response measures such as peak interstory drift ratio and energy dissipated are tracked. These response measures are combined into two damage metrics that account for the ductility and energy dissipation. Results indicate that the duration of the ground motion influences, above all, the combined damage measures, although some effect on drift‐based response measures is also observed for larger levels of drift. These results indicate that because the current assessment methodologies do not capture the effects of ground motion duration, both performance‐based and code‐based assessment methodologies should be revised to consider damage measures that are sensitive to duration. Copyright © 2016 John Wiley & Sons, Ltd  相似文献   

15.
This study presents a seismic fragility analysis of low‐rise masonry in‐filled (MI) reinforced concrete (RC) buildings using a proposed coefficient‐based spectral acceleration method. The coefficient‐based method, without requiring any complicated finite element analysis, is a simplified procedure for assessing the spectral acceleration demand (or capacity) of buildings subjected to earthquakes. This paper begins with a calibration of the proposed coefficient‐based method for low‐rise MI RC buildings using published experimental results obtained from shaking table tests. Spectral acceleration‐based fragility curves for low‐rise MI RC buildings under various inter‐story drift limits are then constructed using the calibrated coefficient‐based method. A comparison of the experimental and estimated results indicates that the simplified coefficient‐based method can provide good approximations of the spectral accelerations at peak loads of low‐rise MI RC buildings, if a proper set of drift‐related factors and initial fundamental periods of structures are used. Moreover, the fragility curves constructed using the coefficient‐based method can provide a satisfactory vulnerability evaluation for low‐rise MI RC buildings under a given performance level. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

16.
This paper investigates the dynamic response of three sample buildings belonging to the Seismic Observatory for Structures, the Italian network for the permanent seismic monitoring of strategic structures, managed by the Italian Department of Civil Protection. The case studies cover different building types that could loosely represent the Italian building stock, with a special emphasis on cultural heritage and masonry structures. Observed under a low‐intensity seismic swarm comprising about 30 aftershocks after a main event, the three buildings are analysed through an input–output, model‐driven linear dynamic identification procedure, depicting the relation between the shaking level at the site and the variation of the equivalent structural modal parameters, while keeping into account the effects of soil–structure interaction. Finite element models will be used to investigate one of the case studies and to compare the law of variation of the structural modal parameters with respect to simplified models proposed by technical standards. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

17.
This paper presents the main results of the evaluation of residual inter‐story drift demands in typical moment‐resisting steel buildings designed accordingly to the Mexican design practice when subjected to narrow‐band earthquake ground motions. Analytical 2D‐framed models representative of the study‐case buildings were subjected to a set of 30 narrow‐band earthquake ground motions recorded on stations placed in soft‐soil sites of Mexico City, where most significant structural damage was found in buildings as a consequence of the 1985 Michoacan earthquake, and scaled to reach several levels of intensity to perform incremental dynamic analyses. Thus, results were statistically processed to obtain hazard curves of peak (maximum) and residual drift demands for each frame model. It is shown that the study‐case frames might exhibit maximum residual inter‐story drift demands in excess of 0.5%, which is perceptible for building's occupants and could cause human discomfort, for a mean annual rate of exceedance associated to peak inter‐story drift demands of about 3%, which is the limiting drift to avoid collapse prescribed in the 2004 Mexico City Seismic Design Provisions. The influence of a member's post‐yield stiffness ratio and material overstrength in the evaluation of maximum residual inter‐story drift demands is also discussed. Finally, this study introduces response transformation factors, Tp, that allow establishing residual drift limits compatible with the same mean annual rate of exceedance of peak inter‐story drift limits for future seismic design/evaluation criteria that take into account both drift demands for assessing a building's seismic performance. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

18.
In this study, the multi‐intensity seismic response of code‐designed conventional and base‐isolated steel frame buildings is evaluated using nonlinear response history analysis. The results of hazard and structural response analysis for three‐story braced‐frame buildings are presented in this paper. Three‐dimensional models for both buildings are created and seismic response is assessed for three scenario earthquakes. The response history analysis results indicate that the design objectives are met and the performance of the isolated building is superior to the conventional building in the design event. For the Maximum Considered Earthquake, isolation leads to reductions in story drifts and floor accelerations relative to the conventional building. However, the extremely high displacement demands of the isolation system could not be accommodated under normal circumstances, and creative approaches should be developed to control displacements in the MCE. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

19.
The objective of the study presented in this paper is to investigate the effects of masonry infills on the shear demand and failure of columns for the case when reinforced concrete frames with such infills are modeled by means of simplified nonlinear models that are not capable of the direct simulation of these effects. It is shown that an approximate simulation of the shear failure of columns can be achieved through an iterative procedure that involves pushover analysis, post‐processing of the analysis results using limit‐state checks of the components, and model adaptation if shear failure of columns is detected. The fragility parameters and the mean annual frequency of limit‐state exceedance are computed on the basis of nonlinear dynamic analysis by using an equivalent SDOF model. The proposed methodology is demonstrated by means of two examples. It was shown that the strength of the four‐story and seven‐story buildings and their deformation capacity are significantly overestimated if column shear failure due to the effects of masonry infills is neglected, whereas the mean annual frequency of limit‐state exceedance for the analyzed limit states is significantly larger than that estimated for the case if the shear failure of columns is neglected. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
A structure that has a permanent offset from a true vertical line is commonly referred to as being ‘out‐of‐plumb’. Out‐of‐plumb may result from construction tolerances or post‐earthquake permanent deformations in steel buildings. This paper quantifies the displacements of buildings with out‐of‐plumb in subsequent seismic events by means of inelastic dynamic time history analysis. Structures considered have different structural heights, force design reduction factors (R), and target inter‐story drifts. It is shown that buildings with greater out of plumb and force design reduction factor have larger normalized peak inter‐story drift ratio and ratio of residual‐to‐peak drift. Also, the ratio of residual‐to‐peak drift was not strongly dependent on structural height or design drift. A design procedure and example provided, based on the results obtained, show how peak and residual inter‐story drift ratio can be estimated. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   