首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Li  Da-yong  Li  Shan-shan  Zhang  Yu-kun  Chen  Fu-quan 《中国海洋工程》2019,33(2):198-206
The modified suction caisson(MSC) is a novel type of foundation for ocean engineering, consisting of a short external closed-top cylinder-shaped structure surrounding the upper part of the regular suction caisson(RSC). The MSC can provide larger lateral bearing capacity and limit the deflection compared with the RSC. Therefore, the MSC can be much more appropriate to use as an offshore wind turbine foundation. Model tests on the MSC in saturated sand subjected to monotonic lateral loading were carried out to investigate the effects of external structure sizes on the sand surface deformation and the earth pressure distribution along the embedded depth. Test results show that the deformation range of the sand surface increases with the increasing width and length of the external structure. The magnitude of sand upheaval around the MSC is smaller than that of the RSC and the sand upheaval value around the MSC in the loading direction decreases with the increasing external structure dimensions. The net earth pressure in the loading direction acting on the internal compartment of the MSC is smaller than that of the RSC at the same embedded depth. The maximum net earth pressure acting on the external structure outer wall in the loading direction is larger than that of the internal compartment, indicating that a considerable amount of the lateral load and moment is resisted by the external skirt structure.  相似文献   

2.
This paper presents a series of monotonically combined lateral loading tests to investigate the bearing capacity of the MSCs(modified suction caissons) in the saturated marine fine sand. The lateral loads were applied under load- and displacement-controlled methods at the loading eccentricity ratios of 1.5, 2.0 and 2.5. Results show that, in the displacement-controlled test, the deflection-softening behavior of load-deflection curves for MSCs was observed, and the softening degree of the load-deflection response increased with the increasing external skirt length or the decreasing loading eccentricity. It was also found that the rotation center of the MSC at failure determined by the load-controlled method is slightly lower than that by the displacement-controlled method. The calculated MSC capacity based on the rotation center position in serviceability limit state is relatively conservative, compared with the calculated capacity based on the rotation center position in the ultimate limit state. In the limit state, the passive earth pressures opposite the loading direction under load- and displacement-controlled methods decrease by 46% and 74% corresponding to peak values, respectively; however, the passive earth pressures in the loading direction at failure only decrease by approximately 3% and 7%, compared with their peak values.  相似文献   

3.
This paper presents a series of monotonically combined lateral loading tests to investigate the bearing capacity of the MSCs (modified suction caissons) in the saturated marine fine sand. The lateral loads were applied under load- and displacement-controlled methods at the loading eccentricity ratios of 1.5, 2.0 and 2.5. Results show that, in the displacement-controlled test, the deflection-softening behavior of load-deflection curves for MSCs was observed, and the softening degree of the load-deflection response increased with the increasing external skirt length or the decreasing loading eccentricity. It was also found that the rotation center of the MSC at failure determined by the load-controlled method is slightly lower than that by the displacement-controlled method. The calculated MSC capacity based on the rotation center position in serviceability limit state is relatively conservative, compared with the calculated capacity based on the rotation center position in the ultimate limit state. In the limit state, the passive earth pressures opposite the loading direction under load- and displacement-controlled methods decrease by 46% and 74% corresponding to peak values, respectively; however, the passive earth pressures in the loading direction at failure only decrease by approximately 3% and 7%, compared with their peak values.  相似文献   

4.
ABSTRACT

The suction caisson is commonly a top-closed cylindrical steel structure with large diameter, short length and much thinner skirt wall thickness. The resistance to penetrating is calculated as the sum of the tip bearing capacity and the adhesion on the both sides of the skirt wall. Since the thickness of the skirt wall is very small, the downward adhesion produced by the skirt wall will cause the additional vertical stress and shear stress in the soil at the skirt tip level, increasing the skirt tip resistance. However, the increase in skirt tip resistance caused by the additional vertical stress rather than shear stress in soil at the skirt tip level was only considered, this may lead to an inaccurate estimation for the tip bearing capacity and the suction required. Thus, a modified slip-line field is put forward in this study to estimate the tip resistance. The expression of obtaining the minimum suction to install the suction caisson in clay is derived in terms of the force equilibrium. Results from calculations of the minimum suction have been proved to be in a good agreement with the measured data.  相似文献   

5.
To study the feasibility and efficiency of underwater suction anchors in soil, the performance of eight model anchors was evaluated in a 30 in. (76·2 cm) by 72 in. (183·0 cm) by 32 in. (81·3 cm) deep test tank. The soil studied were a medium fine sand, a silt and a clay. A gantry-type loading mechanisms was used to apply the vertical breakout force. A pullout rate of approximately 0·1 in/min (0·25 cm/min) was used for all tests.For the range of conditions studied, the test results indicate that the underwater suction anchor is feasible and effective. The breakout behavior of the suction anchors depends upon the anchor geometry including anchor diameter and skirt length, soil strength properties, soil-anchor friction and adhesion, and suction; i.e. the difference between the pressure underneath the porous plate and the ambient pressure. For the anchors and soils tested, the anchor capacity increases linearly with increasing suction provided the anchor skirt length to diameter ratio remains constant. An increase in the anchor capacity results with increasing suction and with increasing internal friction angle of the test soils. To study the results suggest that the underwater suction anchor is particularly useful for short-term anchorage.  相似文献   

6.
A series of model tests was conducted in sand to explore the anti-uplift behavior of suction caissons, considering the effects of aspect ratios, load inclination angles and loading positions. This paper emphasizes on analyzing the deformation characteristic and the mechanism of the suction caissons under various loading conditions. The movement modes of the suction caisson are different when the load inclination angle increases from 0° to 90° corresponding to various mooring positions. The pull-out bearing capacity decreases with load inclination angles increasing. When the load inclination angle changes from 0° to 60°, the bearing capacity reduces more significantly than that between inclination angle of 60° and 90°. While the load inclination angle is relatively small, the pull-out capacity of the suction caisson decreases after reaching the peak as the loading position moves downwards. Moreover, the optimum loading position locates between 2/3 and 3/4 of the caisson length. The optimum loading position is at the bottom of the caisson when the load inclination angle exceeds 60°. However, the influence of the loading position on the pull-out capacity of the caisson can be ignored while the load inclination angle equals to 90°. The pull-out bearing capacity increases as the aspect ratio increases but the aspect ratio has no effect on the deformation characteristic of the suction caisson.  相似文献   

7.
An investigation was conducted to obtain analytical solutions for the pullout behavior of a suction caisson undergoing inclined loads in sand. The inclined load is transformed into an equivalent load system in which the vertical, horizontal, and moment loads are applied on the center of the lid of the suction caisson. The vertical and lateral stiffness coefficients along the skirt of the suction caisson in sands are presented using the new three-dimensional elastic solutions taking into account the nonhomogeneous and nonlinear properties of the sand. The vertical, lateral, and rocking stiffness coefficients on the base of the suction caisson are presented considering the solutions of a hollow rigid cylindrical punch acting on the surface of a soil. The yield, pullout, and failure for sands with the nonhomogeneous and nonlinear characteristics are taken into consideration. The effects of the load inclination, the loading depth, and the aspect ratio on the pullout load capacity of the suction caisson are presented. Behaviour of the suction caisson in sand prior to failure is clarified from the relationship between tensile load, displacement, and rotation and that between depth, vertical pressure, and lateral pressure.  相似文献   

8.
Considering the current disadvantages of present offshore wind turbine foundations, a novel anchor foundation with skirt and branches is proposed, called offshore umbrella suction anchor foundation (USAF). A series of experiments and numerical simulations were performed to explore the bearing capacity of the USAF under various kinds of loading modes. The bearing characteristics and the anchor–soil interactions are described in detail for horizontal static loading, horizontal cyclic loading, and an antidrawing (pullout) test in silty soil. In the static loading test, the load–deflection of the anchor under step loading was analyzed and the normalized curve of the load–deflection was obtained to determine the ultimate horizontal bearing capacity of the anchor under normal working conditions. Under horizontal cyclic loading, the relationship between the plastic cumulative deformation and cyclic number was determined. In addition, the responses of USAF were investigated for a low wave frequency and storm surges. In the drawing test, it was found that a “segmentation phenomenon” occurred during the test. Moreover, a method to identify the maximum antidrawing load of USAF was provided based on dynamic mechanics. The numerical results show that the use of anchor branches and skirt can enhance the bearing performance of USAF to a certain degree. However, the anchor branch has a slight positive influence on the bearing performance improvement. The USAF is not only similar to a stiff short pile, but a rotation occurs. The failure envelope under composite loading (V-M) was obtained and the changes associated with changes in the aspect ratio of the internal compartment were clarified.  相似文献   

9.
This article presents a procedure to calculate the bearing capacity of suction anchors subjected to inclined average and cyclic loads at the optimal load attachment point using the undrained cyclic shear strength of soft clays based on the failure model of anchors proposed by Andersen et al. The constant average shear stress of each failure zone around an anchor is assumed and determined based on the static equilibrium condition for the procedure. The cyclic shear strength of each failure zone is determined based on the average shear stress. The cyclic bearing capacity is finally determined by limiting equilibrium analyses. Thirty-six model tests of suction anchors subjected to inclined average and cyclic loads were conducted, which include vertical and lateral failure modes. Model test results were predicted using the procedure to verify its feasibility. The average relative error between predicted and test results is 1.7%, which shows that the procedure can be used to calculate the cyclic bearing capacity of anchors with optimal loading. Test results also showed that the anchor was still in vertical failure mode under combined average and cyclic loads if an anchor was in vertical failure mode under static loads. The anchor failure would depend on the vertical resistance degradation under cyclic loads if an anchor was in lateral failure mode under static loads. Cyclic bearing capacities associated with the number of load cycles to failure of 1000 were about 75% and 80% of the static bearing capacity for vertical failure anchors and lateral failure anchors, respectively.  相似文献   

10.
近年来大直径钢圆筒结构在离岸人工岛工程中得到应用,如港珠澳大桥人工岛即采用振动下沉的方式安装钢圆筒,该方法对施工条件、装备以及施工控制技术要求较高。提出一种新型隔舱吸力式钢圆筒结构,在钢圆筒内部设置隔舱板,将结构分为上下两个隔舱,通过对下舱抽气实现隔舱吸力式钢圆筒在负压作用下的下沉安装。设计了隔舱吸力式钢圆筒安装及水平承载力模型试验,对比了负压贯入的隔舱吸力式钢圆筒和压力贯入的传统钢圆筒结构的贯入阻力及承载特性,分析了改变隔舱吸力式钢圆筒上下舱高度比L1/L2对其沉贯过程及承载特性的影响。结果表明,采用负压吸力沉贯的隔舱吸力式钢圆筒相比于采用压力贯入的传统钢圆筒结构的贯入阻力减小,水平极限承载力提高。在极限水平荷载作用下,随着隔舱吸力式钢圆筒的L1/L2从2.28减小到1.00、0.56,转动中心位置上移,水平极限承载力及弯矩承载力得到显著提高。  相似文献   

11.
为了研究桩长对海底防沉板—桩复合基础在水平、弯矩和扭转荷载作用下承载特性的影响,以我国南海水深200 m的某工程实例为研究对象,利用Flac3D有限差分仿真软件建立了计算模型。研究了桩长为4 m、6 m和8 m的防沉板—桩复合基础在水平、弯矩和扭转荷载作用下的极限承载力和荷载传递机理。结果表明,桩长超过6 m时复合基础的水平承载力显著增长,在水平加载过程中,防沉板总是先达到极限状态而破坏,桩基础的贡献在加载后期体现,且桩长为4 m、8 m时,桩基础与防沉板的连接处弯矩最大;随着桩长的增加,复合基础的抗弯承载力大幅提高,桩基础对复合基础的抗弯承载力贡献增大,当桩长超过8 m,桩长的增加对提高复合基础的抗弯承载力意义不大;在弯矩加载过程中,桩长对于防沉板、桩基础的荷载分配有显著影响,桩长为4 m时,外荷载主要由防沉板承担,当桩长超过4 m时,外荷载主要由桩基础承担;当扭转荷载不超过2 100 k N·m时,防沉板承担主要荷载,直至防沉板达到极限状态而发生旋转,随后桩基础的承载力逐渐发挥;对于桩长为6 m、8 m的复合基础,其极限状态根据防沉板适用性准则确定。  相似文献   

12.
Monotonic lateral load model tests were carried out on steel skirted suction caissons embedded in the saturated medium sand to study the bearing capacity. A three-dimensional continuum finite element model was developed with Z_SOIL software. The numerical model was calibrated against experimental results. Soil deformation and earth pressures on skirted caissons were investigated by using the finite element model to extend the model tests. It shows that the "skirted" structure can significantly increase the lateral capacity and limit the deflection, especially suitable for offshore wind turbines, compared with regular suction caissons without the "skirted" at the same load level. In addition, appropriate determination of rotation centers plays a crucial role in calculating the lateral capacity by using the analytical method. It was also found that the rotation center is related to dimensions of skirted suction caissons and loading process, i.e. the rotation center moves upwards with the increase of the "skirted" width and length; moreover, the rotation center moves downwards with the increase of loading and keeps constant when all the sand along the caisson's wall yields. It is so complex that we cannot simply determine its position like the regular suction caisson commonly with a specified position to the length ratio of the caisson.  相似文献   

13.
Modified suction caissons (MSCs) acting as offshore wind turbine foundations will generate the accumulated rotation under cyclic loading resulted from waves. The accumulated rotation and the range of soil deformation around the MSC under long-term cyclic wave loading were studied using 3-D numerical simulations. The Morison equation was adopted to calculate the wave loadings. It was found that the MSC accumulated rotation increases linearly with the increase of the logarithm of cyclic number. The normalized expression was proposed to reflect the relationship between the accumulated rotation and cyclic number. The soil deformation range around the MSC increases when increasing the cyclic number and loading amplitude. It can also be concluded that the accumulated rotation increases rapidly with this change of excess pore pressure in the first 4000 cycles. The responses of the MSC to wave and wind loads were also investigated. Results show that the accumulated rotation of the MSC under both wave and wind loadings is larger than that under the wave loading only.  相似文献   

14.
针对一种四筒导管架海上风机基础,基于有限元数值分析,通过建立砂土中不同筒径和筒高的四筒导管架基础有限元模型,研究砂土中单调弯矩荷载的作用下,筒径与筒高对导管架基础抗弯承载力的影响。分析结果表明:四筒导管架风机基础的抗弯承载力随着筒高或筒径的增加呈明显的增长趋势,相比于筒径的增加,筒高的增加对提高基础抗弯承载力更为有效;在极限弯矩荷载的作用下,基础旋转中心水平向位置受筒高的影响较大,但竖向位置受筒高和筒径的影响很小。  相似文献   

15.
A suction caisson can be extracted by applying reverse pumping water,which cannot be regarded as the reverse process of installation because of the dramatically different soil?structure interaction behavior.Model tests were first carried out in this study to investigate the extraction behavior of the modified suction caisson(MSC)and the regular suction caisson(RSC)in sand by reverse pumping water.The effects of the installation ways(suction-assisted or jacking installation)and the reverse pumping rate on the variations of the over-pressure resulting form reverse pumping water were investigated.It was found that neither the RSC nor the MSC can be fully extracted from sand.When the maximum extraction displacement is obtained,the hydraulic gradient of the sand in the suction caisson reaches the critical value,leading to seepage failure.In addition,the maximum extraction displacement decreases with the increasing reverse pumping rate.Under the same reverse pumping rate,the final extraction displacements for the RSC and MSC installed by suction are lower than those for the RSC and MSC installed by jacking.The final extraction displacement of MSC is almost equal to that of the RSC with the same internal compartment length.Based on the force equilibrium,a method of estimating the maximum extraction displacement is proposed.It has been proved that the proposed method can rationally predict the maximum extraction displacement and the corresponding over-pressure.  相似文献   

16.
吸力基础具有施工速度快、安装过程中受海况天气影响小且易于回收重复利用等优点,被广泛应用于海洋工程。当吸力基础作为海上风电塔架的基础时,常常承受较大的水平荷载,因此其水平承载力是设计的主控因素。介绍了海上风机基础的设计要求,分析了影响基础水平承载性状的因素,总结了吸力基础受水平单调荷载、水平循环荷载和不同荷载组合三个方面的研究现状。讨论了水平荷载的大小、水平加载的高度(偏心率)、循环荷载的频率、循环荷载的次数、循环荷载的幅值、循环荷载的方向性、竖向荷载对吸力基础水平承载性状的影响,考虑了水平荷载的非共线性,指出了目前研究的不足,明确了吸力基础水平承载性状进一步研究的方向,提出了供工程实践参考的建议。  相似文献   

17.
复合加载条件下吸力式沉箱基础承载特性数值分析   总被引:2,自引:0,他引:2  
王志云  王栋  栾茂田  范庆来  武科 《海洋工程》2007,25(2):52-56,71
吸力式沉箱基础的承载特性是海洋工程结构设施建造与设计中的一个关键问题。这种新型的深水海洋基础型式,通常承受竖向上拔荷载与水平荷载的共同作用,其工作性能与设计理论远远不能满足工程实践的需要。本文采用有限元分析方法对吸力式沉箱基础的极限承载特性进行数值计算。以大型通用有限元分析软件ABAQUS为平台,通过二次开发,数值实现了Swipe试验加载方法和固定位移比分析方法,针对不同的沉箱长径比、土的强度折减系数,探讨了沉箱基础在垂直上拔荷载和水平荷载单调联合作用下的极限承载力,通过对不同荷载组合的数值计算构造了复合加载条件下沉箱基础破坏包络面。  相似文献   

18.
The passive suction of suction foundations plays a significant role in pull-out resistance. The factors influencing the uplift capacity include stress state, embedment ratio, and loading rate. This article investigates the effect of embedment ratio and loading rate on the bearing behavior of suction foundations using centrifuge testing. A series of uplift tests on a suction foundation in clay were performed using a beam centrifuge. During the tests, uplift displacement, suction, and loading rate were monitored. The suction was obtained by measurement of water pressure. To compare the influence of different factors on uplift capacity due to passive suction, two types of uplift tests were conducted; the first was on the closed caisson and the second was on the vented caisson. The results show that the pull-out resistance increased with an increase of the uplift loading rate, which was induced by the suction. The maximum resistance occurred when the upward displacements reached 14%D under a ratio of skirt length (L) to diameter (D) (L/D) of 0.5 and 17%D under an L/D ratio of 2. These findings provide a way for suction caissons to resist pull-out load or for structures to be removed from the seabed.  相似文献   

19.
自升式钻井平台插桩是地基土在桩靴荷载作用下发生连续的塑性破坏的动态过程,当地基极限承载力等于桩靴荷载时插桩完成。经典土力学极限承载力理论对土体潜在滑动面做了假设,无法有效分析土体内部的破坏过程。本研究应用有限元法(FEM )对插桩过程进行了模拟,得到地基土的破坏机制以及中间荷载下土体的应力、应变情况,通过和各理论公式计算的极限承载力进行对比分析,分析影响地基极限承载力的因素。研究表明,基础宽度与硬土层厚度的比值 B/H越大,下卧软土层越容易发生塑性破坏,极限承载力明显下降,当B/H<0.286时,可以忽略下卧软土层对地基承载力的影响。  相似文献   

20.
A series of model tests were performed on steel- and Perspex-made suction caissons in saturated dense marine sand to explore installation and extraction behaviors. The extractions of the caisson were conducted by applying monotonic loading or by pumping water into the caisson. Responses of suction caissons to pullout rates, aspect ratios, and extraction manners were examined. Test results show that a cone-shaped subsidence region occurs around the suction caisson during the suction-assisted installation. The pullout bearing capacity of the suction caisson in sand is dominated by the loading rate and the loading manner. For the suction caisson subjected to monotonic loading, the maximum bearing capacity is reached at the pullout rate of about 20.0?mm/s. The mobilized vertical displacement corresponding to the pullout capacity increases with increasing the pullout rate. The passive suction beneath the suction caisson lid reaches the maximum value when the pullout bearing capacity is mobilized. In addition, during the suction caisson extracted by pumping water into the caisson, the maximum pore water pressure in the caisson is obtained under the displacement of approximately 0.04 times the caisson diameter. The absolute values of the maximum pore water pressures for the suction caissons approximately equal those of the maximum vertical resistances at the monotonic pullout rate of 5 mm/s. When the vertical displacements of the suction caissons with the aspect ratio of 1.0 and 2.0 reach 0.92 and 1.77 times the caisson diameter, respectively, the seepage failure occurs around the caissons. Using a scaling method, the test results can be used to predict the time length required for the prototype suction caisson to be extracted from the seabed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号