首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 21 毫秒
1.
A series of model tests were performed on steel- and Perspex-made suction caissons in saturated dense marine sand to explore installation and extraction behaviors. The extractions of the caisson were conducted by applying monotonic loading or by pumping water into the caisson. Responses of suction caissons to pullout rates, aspect ratios, and extraction manners were examined. Test results show that a cone-shaped subsidence region occurs around the suction caisson during the suction-assisted installation. The pullout bearing capacity of the suction caisson in sand is dominated by the loading rate and the loading manner. For the suction caisson subjected to monotonic loading, the maximum bearing capacity is reached at the pullout rate of about 20.0?mm/s. The mobilized vertical displacement corresponding to the pullout capacity increases with increasing the pullout rate. The passive suction beneath the suction caisson lid reaches the maximum value when the pullout bearing capacity is mobilized. In addition, during the suction caisson extracted by pumping water into the caisson, the maximum pore water pressure in the caisson is obtained under the displacement of approximately 0.04 times the caisson diameter. The absolute values of the maximum pore water pressures for the suction caissons approximately equal those of the maximum vertical resistances at the monotonic pullout rate of 5 mm/s. When the vertical displacements of the suction caissons with the aspect ratio of 1.0 and 2.0 reach 0.92 and 1.77 times the caisson diameter, respectively, the seepage failure occurs around the caissons. Using a scaling method, the test results can be used to predict the time length required for the prototype suction caisson to be extracted from the seabed.  相似文献   

2.
A series of model tests were conducted on Perspex-made suction caissons in saturated dense marine sand to study the sand plug formation during extraction. Suction caissons were extracted by pullout loading or by pumping air into the suction caisson. Effects of the pullout rates, aspect ratios and loading ways (monotonic or sustained) on the pullout capacity, and plug formation were investigated. It was found that the ultimate pullout capacity of the suction caisson increases with increasing the pullout rate. The sand plug formation under the pullout loading is significantly influenced by the pullout rate and the loading way. When the suction caisson is extracted at a relatively slow rate, the general sand boiling through the sand plug along the inner caisson wall occurs. On the contrary, the local sand boiling will occur at the bottom of the suction caisson subjected to a rapid monotonic loading or a sustained loading. Test results of the suction caisson extracted by pumping air into the caisson show that the pressure in the suction caisson almost follows a linear relationship with the upward displacement. The maximum pressures for suction caissons with aspect ratios of 1.0 and 2.0 during extraction by pumping air into the caisson are 1.70 and 2.27 times the maximum suction required to penetrate the suction caisson into sand. It was found that the sand plug moves downward during extraction by pumping air into the caisson and the variation in the sand plug height is mainly caused by the outflow of the sand particles from the inside of the suction caisson to the outside. When the suction caisson model is extracted under the pullout rate of 2?mm/s (0.28?mm/s for the prototype), the hydraulic gradient along the suction caisson wall increases to the maximum value with increasing the penetration depth and then reduces to zero. On the contrary, when extracted under the pullout rate of 10?mm/s (1.4?mm/s for the prototype), the hydraulic gradient along the suction caisson wall increases with increasing the pullout displacement. When extracted by pumping air into the caisson, the hydraulic gradient reaches the critical value, and at the same time, the seepage failure occurs around the suction caisson tip.  相似文献   

3.
Li  Da-yong  Li  Shan-shan  Zhang  Yu-kun  Chen  Fu-quan 《中国海洋工程》2019,33(2):198-206
The modified suction caisson(MSC) is a novel type of foundation for ocean engineering, consisting of a short external closed-top cylinder-shaped structure surrounding the upper part of the regular suction caisson(RSC). The MSC can provide larger lateral bearing capacity and limit the deflection compared with the RSC. Therefore, the MSC can be much more appropriate to use as an offshore wind turbine foundation. Model tests on the MSC in saturated sand subjected to monotonic lateral loading were carried out to investigate the effects of external structure sizes on the sand surface deformation and the earth pressure distribution along the embedded depth. Test results show that the deformation range of the sand surface increases with the increasing width and length of the external structure. The magnitude of sand upheaval around the MSC is smaller than that of the RSC and the sand upheaval value around the MSC in the loading direction decreases with the increasing external structure dimensions. The net earth pressure in the loading direction acting on the internal compartment of the MSC is smaller than that of the RSC at the same embedded depth. The maximum net earth pressure acting on the external structure outer wall in the loading direction is larger than that of the internal compartment, indicating that a considerable amount of the lateral load and moment is resisted by the external skirt structure.  相似文献   

4.
Offshore wind power is a rapidly growing area of electricity in China. In the present paper, interaction mechanisms between the caisson for wind turbines and saturated silt sand are investigated with laboratory tests based on two different installation methods, jacking installation and suction installation. For the jacking installation process, the results indicate that the soil pressures inner and outer the skirt of the caisson vary with a similar feature and the magnitudes of the two are nearly balanced. The tip resistance plays a key role in the total jacking installation resistance. This paper examines the predictive performance of qc method and API approach for jacking installation resistance. It is demonstrated that the qc method provides better predictions. The resistance coefficients are recommended. For the case of suction installation, however, the changes of soil pressures inner and outer the skirt are contrasting. Specifically, the inner pressure and tip resistance fall dramatically, but the outer pressure increases when suction is applied. Seepage effect is found to be an important mechanism for the installation of suction caisson. The reduction ratios of the inner friction and tip resistance follow a power-function with the normalized suction. Based on the test results, a prediction method for the required suction has been developed and evaluated.  相似文献   

5.
The suction caisson (or called suction anchor) which is considered as a relatively new type of foundation of offshore structures, has been extensively studied and applied for offshore wind turbines and oil platforms. The installation of the suction caisson is of great importance in the design and construction because it can bring about several issues and further influence the performance of holding capacity in safety service. In this paper, large deformation finite element (FE) analyses are performed to model the installation of suction caisson (SC) by suction and jacking in normally consolidated clay. The penetration of the suction caisson is modeled using an axisymmetric FE approach with the help of the Arbitrary Lagrangian–Eulerian (ALE) formulation which can satisfactorily solve the large deformation problem. The undrained shear strength of the clay and elastic modulus are varied with depth of soil through the subroutine VUFIELD. The numerical results allow quantification of the penetration resistance and its dependence on the installation method. The centrifuge test and theoretical solution are used for the FE model validation. After the validation, the penetration resistance, the soil plug heave, and the caisson wall friction have been examined through the FE model. Based on the numerical results, it is shown that the ALE technique can simulate the entire suction caisson penetration without mesh distortion problem. The installation method can play an important role on the penetration resistance, namely, the suction installation reduces the penetration resistance significantly compared to the purely jacked installation. With a further study on the suction case, it is found that as the final applied suction pressure increases, the soil plug heave increases, while the penetration resistance reduces with increase of the final suction pressure. The effect of the friction of internal caisson walls has been also investigated and a conclusion is drawn that internal wall friction has a significant contribution to the penetration resistance and it can be implicitly represented by varying coefficient of internal wall friction. As for the penetration resistance, both jacked and suction installation have great dependency on the internal wall friction.  相似文献   

6.
Abstract

The performance of steel caisson during and after installation with different penetration velocities in medium dense sand is presented. The applied jacking forces, the amount of formed soil heave and bearing capacity were measured in the model tests. The influence of penetration velocities on jacking forces, soil heave and bearing capacity were also discussed in detail. The results indicated that the jacking forces for caisson in medium dense sands were significantly affected by the penetration velocity. The larger the penetration velocity, the more soil flowed into the caisson cavity during installation. This will lead to larger inner shaft resistance and in turn more jacking forces required for the same penetration depth. The height of soil heave during installation increases with penetration velocity. The m value calculated by the ratio of the volumes of the soil heave to that of the penetrated caisson wall can be used to evaluate the soil heave. The larger the applied velocity, the larger the m value and larger bearing capacity of caisson after installation. The relationship between the m value and penetration velocity can be used to control the soil heave for a steel caisson with a wall thickness to external diameter ratio of 4.2% in medium dense sand by jacking method.  相似文献   

7.
An investigation was conducted to obtain analytical solutions for the pullout behavior of a suction caisson undergoing inclined loads in sand. The inclined load is transformed into an equivalent load system in which the vertical, horizontal, and moment loads are applied on the center of the lid of the suction caisson. The vertical and lateral stiffness coefficients along the skirt of the suction caisson in sands are presented using the new three-dimensional elastic solutions taking into account the nonhomogeneous and nonlinear properties of the sand. The vertical, lateral, and rocking stiffness coefficients on the base of the suction caisson are presented considering the solutions of a hollow rigid cylindrical punch acting on the surface of a soil. The yield, pullout, and failure for sands with the nonhomogeneous and nonlinear characteristics are taken into consideration. The effects of the load inclination, the loading depth, and the aspect ratio on the pullout load capacity of the suction caisson are presented. Behaviour of the suction caisson in sand prior to failure is clarified from the relationship between tensile load, displacement, and rotation and that between depth, vertical pressure, and lateral pressure.  相似文献   

8.
Concrete suction caissons have been successfully used as breakwaters or seawalls in recent years. The relative large wall thickness-to-diameter ratio of a concrete caisson can lead to the formation of a full soil heave plug that may cause difficulties in the installation of concrete caisson in clay. One way to overcome this limitation is to use a tampered tip for the caisson wall. An analytical method is proposed in this article to calculate the minimum suction pressure required to penetrate a caisson and the maximum allowable suction pressure that can be applied to avoid too much soil heave plug during the installation of the suction caisson. Four model tests were conducted in normally consolidated clay to study the installation process of a concrete suction caisson with tampered tip and to verify the proposed analytical method. The height of the soil heave plug in the caisson with a tampered tip is observed to be about half of that in the caisson with a flat tip.  相似文献   

9.
吸力基础与海洋工程大直径钢桩相比,具有成本低、安装周期短、对环境影响小、不受海况影响及可回收再利用等优点,近年来在海上风电工程中得到推广应用。吸力基础沉贯至海床预定位置,是其发挥承载力和确保服役稳定性的前提。海床地基土体常以分层土形式分布,且各层土体强度、压缩性和渗透性等存在显著差别,导致吸力基础吸力沉贯机理非常复杂。明确吸力基础在分层土中沉贯特性,有助于指导吸力基础在海上风电工程中的推广应用。对目前吸力基础在分层土中沉贯特性研究进行综述和总结,归纳了其沉贯机理研究进展,并对影响吸力基础在分层土中沉贯因素进行了分析;提出了分层土中吸力基础沉贯的研究方向和改进的沉贯方法。  相似文献   

10.
The passive suction of suction foundations plays a significant role in pull-out resistance. The factors influencing the uplift capacity include stress state, embedment ratio, and loading rate. This article investigates the effect of embedment ratio and loading rate on the bearing behavior of suction foundations using centrifuge testing. A series of uplift tests on a suction foundation in clay were performed using a beam centrifuge. During the tests, uplift displacement, suction, and loading rate were monitored. The suction was obtained by measurement of water pressure. To compare the influence of different factors on uplift capacity due to passive suction, two types of uplift tests were conducted; the first was on the closed caisson and the second was on the vented caisson. The results show that the pull-out resistance increased with an increase of the uplift loading rate, which was induced by the suction. The maximum resistance occurred when the upward displacements reached 14%D under a ratio of skirt length (L) to diameter (D) (L/D) of 0.5 and 17%D under an L/D ratio of 2. These findings provide a way for suction caissons to resist pull-out load or for structures to be removed from the seabed.  相似文献   

11.
Components of suction caisson capacity measured in axial pullout tests   总被引:1,自引:0,他引:1  
Adam M.  Alan F.  Roy E.  Elliott C.   《Ocean Engineering》2005,32(7):878-891
Suction caissons are the foundation of choice for offshore structures in deep water. Systematic study of caisson behavior is relegated to the laboratory due to the high cost of full-scale testing. Our laboratory caisson was installed in normally consolidated clay using dead weight and suction. Tensile axial capacity was measured with the top cap vented or sealed, and with the soil undrained or drained. For the common case of rapid pullout with a sealed top, the test results indicate an external side resistance factor (α) of 0.5–0.8 and a reverse end bearing factor (Nc) of 13–21.  相似文献   

12.
Suction-induced seepage is pivotal to the installation of caisson foundations in sand. Indeed, the upward pore water flow on the inner side of the caisson wall causes a release of a fraction of soil resistance due to the reduction of the lateral effective stress. A safe caisson installation requires a reliable prediction of soil conditions, especially soil resistance and critical suction for piping. These soil conditions must be predicted for the whole installation process.In this paper, we examine the effect on such prediction of the assumed permeability profile, which is described as a function of depth below the mudline. This study is motivated by the fact that marine sediments generally exhibit a permeability that decreases with depth because of consolidation under gravity. Hence, the question is whether conventional theories based on a constant permeability lead to a conservative prediction of soil conditions or not. Our conclusion is affirmative only regarding piping condition. As for soil resistance, a prediction based on the assumption of a constant permeability is non-conservative. This is due to an overestimated reduction in effective stresses under suction-induced seepage.  相似文献   

13.
An investigation was made to present analytical solutions of cyclic response to suction caisson subjected to inclined cyclic loadings in clay using a three-dimensional displacement approach. A model representing the relationship between vertical load and vertical displacement and that between lateral load and lateral displacement along the skirt of suction caisson subjected to cyclic loadings is proposed for overconsolidated clay. For the effect of vertical load on cyclic load capacity of suction caisson, using the Mindlin solution in the case of a vertical point load, the vertical stress of soil under the base of suction caisson is presented. For the stress state of soil beneath the base of suction caisson subjected to cyclic loading, the Mohr–Coulomb failure line and critical state line are presented and the relationship between total stress, effective mean principal stress, stress difference, and pore-pressure is elucidated. The comparison of results predicted by the present method for a suction caisson subjected to cyclic loadings in clay has shown good agreement with those obtained from field tests. Cyclic behavior of clay up to failure is made clear from the relationship between cyclic tensile load, vertical and lateral displacements, and rotation and that between depth, vertical, and lateral pressures.  相似文献   

14.
Dai  Guo-liang  Zhu  Wen-bo  Zhai  Qian  Gong  Wei-ming  Zhao  Xue-liang 《中国海洋工程》2019,33(6):685-693
Suction caisson foundation derives most of their uplift resistance from passive suction developed during the pullout movement. It was observed that the passive suction generated in soil at the bottom of the caisson and the failure mode of suction caisson foundation subjecting pullout loading behaves as a reverse compression failure mechanism.The upper bound theorems have been proved to be a powerful method to find the critical failure mechanism and critical load associated with foundations, buried caissons and other geotechnical structures. However, limited attempts have been reported to estimate the uplift bearing capacity of the suction caisson foundation using the upper bound solution. In this paper, both reverse failure mechanisms from Prandtl and Hill were adopted as the failure mechanisms for the computation of the uplift bearing capacity of the suction caisson. New equations were proposed based on both failure mechanisms to estimate the pullout capacity of the suction caisson. The proposed equations were verified by the test results and experimental data from published literature. And the two solutions agree reasonably well with the other test results. It can be proved that both failure mechanisms are reasonably and more consistent with the actual force condition.  相似文献   

15.
A series of model tests was conducted in sand to explore the anti-uplift behavior of suction caissons, considering the effects of aspect ratios, load inclination angles and loading positions. This paper emphasizes on analyzing the deformation characteristic and the mechanism of the suction caissons under various loading conditions. The movement modes of the suction caisson are different when the load inclination angle increases from 0° to 90° corresponding to various mooring positions. The pull-out bearing capacity decreases with load inclination angles increasing. When the load inclination angle changes from 0° to 60°, the bearing capacity reduces more significantly than that between inclination angle of 60° and 90°. While the load inclination angle is relatively small, the pull-out capacity of the suction caisson decreases after reaching the peak as the loading position moves downwards. Moreover, the optimum loading position locates between 2/3 and 3/4 of the caisson length. The optimum loading position is at the bottom of the caisson when the load inclination angle exceeds 60°. However, the influence of the loading position on the pull-out capacity of the caisson can be ignored while the load inclination angle equals to 90°. The pull-out bearing capacity increases as the aspect ratio increases but the aspect ratio has no effect on the deformation characteristic of the suction caisson.  相似文献   

16.
The modified suction caisson (MSC) adds a short-skirted structure around the regular suction caissons to increase the lateral bearing capacity and limit the deflection. The MSC is suitable for acting as the offshore wind turbine foundation subjected to larger lateral loads compared with the imposed vertical loads. Determination of the lateral bearing capacity is a key issue for the MSC design. The formula estimating the lateral bearing capacity of the MSC was proposed in terms of the limit equilibrium method and was verified by the test results. Parametric studies on the lateral bearing capacity were also carried out. It was found that the lateral bearing capacity of the MSC increases with the increasing length and radius of the external skirt, and the lateral bearing capacity increases linearly with the increasing coefficient of subgrade reaction. The maximum lateral bearing capacity of the MSC is attained when the ratio of the radii of the internal compartment to the external skirt equals 0.82 and the ratio of the lengths of the external skirt to the internal compartment equals 0.48, provided that the steel usage of the MSC is kept constant.  相似文献   

17.
Dai  Guo-liang  Zhu  Wen-bo  Zhai  Qian  Gong  Wei-ming  Zhao  Xue-liang 《中国海洋工程》2020,34(2):267-278
Suction caisson foundations are often subjected to vertical uplift loads, but there are still no wide and spread engineering specifications on design and calculation method for uplift bearing capacity of suction caisson foundation.So it is important to establish an uplift failure criterion. In order to study the uplift bearing mechanism and failure mode of suction caisson foundation, a series of model tests were carried out considering the effects of aspect ratio,soil permeability and loading mode. Test results indicate that the residual negative pressure at the top of caisson is beneficial to enhance uplift bearing capacity. The smaller the permeability coefficient is, the higher the residual negative pressure will be. And the residual negative pressure is approximately equal to the water head that causes seepage in the caisson. When the load reaches the ultimate bearing capacity, both the top and bottom negative pressures are smaller than Su and both the top and bottom reverse bearing capacity factors are smaller than 1.0 in soft clay. Combined the uplift bearing characteristics of caisson in sandy soil and soft clay, the bearing capacity composition and the calculation method are proposed. It can provide a reference for the engineering design of suction caisson foundation under vertical load.  相似文献   

18.
Monopod caisson foundation is a viable alternative for supporting offshore wind turbines located at shallow water depths. This foundation system has to resist overturning moment generated due to resultant lateral load, arising from wind and water wave action, that can act at any loading height above the seabed. This paper presents results of a numerical investigation performed to determine the influence of loading height, caisson geometry and superstructure load on the ultimate lateral capacity, initial stiffness, and soil failure zone of the foundation, when installed in very dense sand. Both the ultimate and serviceable states of the caisson foundation obtained from the analyses are represented in terms of envelopes plotted between lateral load and overturning moment. Simplified expressions, which take into account the influence of caisson geometry, loading height, and soil properties, are also presented to serve as a preliminary base for design of the monopod caisson foundation.  相似文献   

19.
Monotonic lateral load model tests were carried out on steel skirted suction caissons embedded in the saturated medium sand to study the bearing capacity. A three-dimensional continuum finite element model was developed with Z_SOIL software. The numerical model was calibrated against experimental results. Soil deformation and earth pressures on skirted caissons were investigated by using the finite element model to extend the model tests. It shows that the "skirted" structure can significantly increase the lateral capacity and limit the deflection, especially suitable for offshore wind turbines, compared with regular suction caissons without the "skirted" at the same load level. In addition, appropriate determination of rotation centers plays a crucial role in calculating the lateral capacity by using the analytical method. It was also found that the rotation center is related to dimensions of skirted suction caissons and loading process, i.e. the rotation center moves upwards with the increase of the "skirted" width and length; moreover, the rotation center moves downwards with the increase of loading and keeps constant when all the sand along the caisson's wall yields. It is so complex that we cannot simply determine its position like the regular suction caisson commonly with a specified position to the length ratio of the caisson.  相似文献   

20.
介绍了青岛银海大世界旅游交通码头工程在沉箱进水孔开关的设置过程中,采用了人工在沉箱顶部平台上通过绳索牵引设置在进水孔外侧盖板上的杠杆来控制进水孔开启、关闭的工艺。该工艺与传统采用定型阀门控制的工艺相比具有:结构简单、安装方便、操作安全、成本低廉的优势。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号