首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
Hydraulic processes in porous media can be monitored in a minimally invasive fashion by time-lapse electrical resistivity tomography (ERT). The permanent installation of specifically designed ERT instrumentation, telemetry and information technology (IT) infrastructure enables automation of data collection, transfer, processing, management and interpretation. Such an approach gives rise to a dramatic increase in temporal resolution, thus providing new insight into rapidly occurring subsurface processes. In this paper, we discuss a practical implementation of automated time-lapse ERT. We present the results of a recent study in which we used controlled hydraulic experiments in two test cells at reduced field scale to explore the limiting conditions for process monitoring with cross-borehole ERT measurements. The first experiment used three adjacent boreholes to monitor rapidly rising and falling water levels. For the second experiment, we injected a saline tracer into a homogeneous flow field in freshwater-saturated sand; the dynamics of the plume were then monitored with 2D measurements across a 9-borehole fence and 3D measurements across a 3 × 3 grid of boreholes. We investigated different strategies for practical data acquisition and show that simple re-ordering of ERT measurement schemes can help harmonise data collection with the nature of the monitored process. The methodology of automated time-lapse ERT was found to perform well in different monitoring scenarios (2D/3D plus time) at time scales associated with realistic subsurface processes. The limiting factor is the finite amount of time needed for the acquisition of sufficiently comprehensive datasets. We found that, given the complexity of our monitoring scenarios, typical frame rates of at least 1.5–3 images per hour were possible without compromising image quality.  相似文献   

2.
An integrated approach for monitoring the vertical transport of a solute into the subsurface by using a geophysical method and a simulation model is proposed and evaluated. A medium-scale (1 m3) laboratory tank experiment was constructed to represent a real subsurface system, where an olive-oil mill wastewater (OOMW) spill might occur. High-resolution cross-hole electrical resistivity tomography (ERT) was performed to monitor the OOMW transport. Time-lapse ERT images defined the spatial geometry of the interface between the contaminated and uncontaminated soil into the unsaturated and saturated zones. Knowing the subsurface characteristics, the finite element flow and transport model FEFLOW was used for simulating the contaminant movement, utilizing the ERT results as a surrogate for concentration measurements for the calibration process. A statistical analysis of the ERT measurements and the corresponding transport model results for various time steps showed a good agreement between them. In addition, a sensitivity analysis of the most important parameters of the simulation model (unsaturated flow, saturated flow and transport) was performed. This laboratory-scale study emphasizes that the combined use of geophysical and transport-modeling approaches can be useful for small-scale field applications where contaminant concentration measurements are scarce, provided that its transferability from laboratory to field conditions is investigated thoroughly.  相似文献   

3.
重非水相流体(DNAPLs)的电阻率一般较高,在地下介质中与周围的地下水形成明显的电性差别。利用这一特性,非侵入式的高密度电阻率法(ERT)在探测DNAPLs污染场址中污染范围展现出一定优势。然而在实际场址的调查应用中,ERT有时无法探测到显著的高阻异常,或探测的高阻异常是由于介质的非均质性产生,从而导致对DNAPLs污染分布的误判。针对该问题,文章首先基于有效介质电阻率模型,计算了不同DNAPLs饱和度情形下的地层总电阻率值,从理论上解释了当DNAPLs污染程度较低时不存在显著高阻异常的原因。进一步构建理想ERT正演模型,探讨ERT探测DNAPLs污染的适宜性。研究结果表明:介质的非均质性(例如高阻的砾石等)对ERT探测具有很强的干扰,可造成DNAPLs分布范围的误判,因此传统静态ERT探测DNAPLs污染仅适用于均质介质或者非均质介质中DNAPLs污染程度较高的条件。对于非均质介质DNAPLs污染程度较低时,需采用基于时间域的差分反演方法屏蔽介质非均质性的影响,从而准确判定DNAPLs分布。  相似文献   

4.
Moisture content is considered to play an important role in the degradation of municipal solid waste (MSW). The present study was carried out to test the use of electrical resistivity tomography (ERT) to estimate the daily variations in the volumetric moisture content (VMC) during waste degradation. The degradation of MSW in a laboratory-scale reactor was monitored daily by ERT and time domain reflectometry (TDR) over a period of 55 days after the waste was landfilled. The bulk electrical resistivity, normalised to a standard temperature of 25 °C, was compared to the VMC obtained by TDR. The relationship between the bulk electrical resistivity and the VMC was not obvious in the upper unit, because there was a bias in the positions of the ERT and TDR measurements due to the settling of the waste. However, the bulk electrical resistivity depended on the VMC in the lower unit of the reactor. According to a power equation fitted in the lower unit, the 2-D distributions of the VMC are presented. Variations in the VMC reflected the processes of waste degradation and leachate transportation. Furthermore, the volume of water stored in the lower unit of the reactor was calculated and found to be consistent with that estimated from the gravimetric moisture content during waste sampling. The data showed that ERT could be used to estimate the variations in moisture content in the initial period following the landfilling of waste.  相似文献   

5.
The principal aim of this study is to assess the scope of monitoring diesel plume migration in a scaled aquifer model with a miniaturised electrical resistivity array. Respectively 1000 and 500 ml of diesel were injected in both the unsaturated and water-saturated zones of a sand body overlying a clay aquitard, and diesel migration was monitored with a miniature electrode array and an off-the-shelf resistivity meter. Inverted time-lapse electrical resistivity tomography (ERT) data reflect downward and lateral spreading of the diesel plume away from the injection point in the unsaturated zone. Diesel was also imaged to spread upwards and laterally away from the injection point in the saturated zone, as controlled by capillary rise. In both cases later-time ERT images reflected preferential pooling of diesel on the water table, as well as vertical smearing of pooled diesel in response to simulated water-table fluctuations. Repeat fluid electrical conductivity (EC) and dissolved oxygen (DO) measurements validate the observed changes in bulk resistivity caused by both diesel injections. Artefacts introduced by 2D inversion of 3D contaminant transport were abound. Time-lapse ERT imaging of diesel transport is therefore inferred to be feasible and well-suited to complementing conventional techniques of intrusive site investigation, although time-lapse 3D or 4D ERT imaging is strongly advocated.  相似文献   

6.
二维孔隙介质中重非水相液体饱和度测定与分析   总被引:2,自引:0,他引:2       下载免费PDF全文
在二维均质饱和孔隙介质中利用光透法与高密度电阻率法定量监测重非水相液体(DNAPL)的运移过程与饱和度。 将光透法与高密度电阻率法相结合,进行高密度电阻率法对 DNAPL 在饱和多孔介质中渗流过程的定量监测。在二维砂箱 中进行 DNAPL 的入渗试验,应用光透法与高密度电阻率法进行动态监测,分别利用 CCD 相机、LCR 数字电桥采集数据。 光透法的数据处理采用“水-DNAPL”两相中 DNAPL 饱和度的计算公式。而高密度电阻率法的数据处理是将获得的电阻值 数据转化为电阻率值,然后利用 Archie 公式获得重非水相液体的饱和度空间分布。Archie 公式中参数β值本文采用与光透法 相结合的新方法来获取,克服了传统方法获取β值时存在的困难。根据不同时刻的饱和度空间分布可以估算注入砂箱内的 DNAPL 总量,并将其与实测的入渗量进行对比。结果表明,与光透法结合后的高密度电阻率成像法能定量监测饱和孔隙介 质中 DNAPL 的入渗过程,且估算的 DNAPL 入渗量与实测值比较吻合,提出的基于光透法计算β值的新方法是有效且可行的。  相似文献   

7.
土体在气候作用下发育干缩裂隙是一种常见的自然现象,裂隙的存在会极大弱化土体的工程性质,诱发许多岩土与地质工程问题。为了实时掌握黏性土中干缩裂隙网络的发展状态,提出了一套基于高密度电阻率层析成像技术(ERT)的土体干缩裂隙动态发展过程精细监测方法。分别开展模型试验及原位试验,利用自行研制的测定系统持续采集电流-电位差数据,随后利用自行开发的有限元法电阻率层析成像(FemERT)系统进行数据处理,获取了裂隙网络在不同发育阶段的空间分布特征。结果表明:(1)ERT可以实现土体裂隙发育过程的精细监测,具备监测三维裂隙网络几何形态的能力,裂隙宽度的识别精度达到毫米级,裂隙深度的识别精度达到厘米级;(2)ERT的感度分布特征解释了裂隙发育对于土体电阻率的影响规律,测定电阻值时程曲线因裂隙产生位置的不同而呈现不同的变化规律;(3)反演电阻率及其相对变化率(Rev)可以直观表征裂隙网络在不同阶段的空间几何形态,凸显裂隙动态发育过程对于土体导电性的影响。  相似文献   

8.
为了探究土体干缩开裂问题,文章采用ERT技术,对黏性土开展了一维干缩开裂动态监测试验。配制初始状态饱和 的泥浆试样,在自然条件下干燥,采用ERT技术获得试样干燥过程中的电阻值变化。结合试样的电阻值图像和裂隙图像, 对土体干缩开裂规律进行了分析。研究结果表明:在干燥蒸发初期,土体电阻值随时间增加缓慢减小,其原因在于土体干 燥收缩导致土颗粒间接触面积增大,颗粒水化膜变薄,进而使得土颗粒表面双电层导电性增强。随着干燥继续进行,气体 进入土体内部,土体由初始饱和状态转变为非饱和状态,电阻值转为缓慢增加。当土体产生裂隙时,裂隙周围土体电阻值 急剧增大,而未发育裂隙的土体电阻依然保持缓慢增加的趋势。通过对比试样电阻值变化曲线和裂隙图像,发现两者所呈 现的裂隙发育位置和状态存在良好的一致性。因此,ERT技术能对干燥过程中土体裂隙发育进行有效的动态监测,准确掌 握裂隙发育的时空动态信息,并且能提前预测裂隙发育的可能位置,为研究极端干旱气候作用下土体的工程性质响应提供 了理想手段。  相似文献   

9.
Electrical resistance tomography (ERT) was used to monitor a conductive plume dilution experiment that was conducted in fractured basalt in order to assess its applications in this type of fractured-rock environment. Tap water was injected into an injection well for 34 days to dilute a pre-existing potassium chloride (KCl) plume at a site in Idaho, USA. No further fluids were introduced artificially during a 62-day monitoring period. Both surface ERT and cross-borehole ERT were used to monitor dilution and displacement of the plume. A square grid of land-surface electrodes was used with the surface ERT. Three-dimensional images of surface ERT delineated areas of increased and decreased resistivities. Increasing resistivities are attributed to dilution/displacement of the KCl solution by tap-water invasion or the influx of seasonal recharge. Decreasing resistivities resulted from redistribution of residual KCl solution. Cross-borehole ERT was conducted between the injection well and each of seven surrounding monitoring wells. Polar plots of the injection-well resistivity data in the direction of each monitoring well delineate specific locations where tap water seeped from the injection well via preferential flow paths determined by time-dependent resistivity increases. Monitoring-well data indicate locations of clustered and isolated regions of resistivity changes.  相似文献   

10.
Geoelectrical methods involving electrical resistivity tomography (ERT), self-potential (SP), frequency domain electromagnetic (FDEM), and very low frequency (VLF) methods have been used to provide valuable information in locating a known sulfide ore body in Soap Gulch, Montana. The study develops basis of comparison for the geophysical techniques employed. Ranges of resistivity along the area have been established using interpreted ERT which can help to understand the subsurface distribution of sulfides in the area. A sulfide body was delineated from the survey area corresponding to anomalously low resistivity values on the ERT section, negative SP, and high apparent current density zone in VLF. Depth to the localized ore zone ranges approximately from 10 to 20 m. FDEM data reflect the conductivity distribution of the shallow subsurface (less than 6 m deep); hence, the delineated sulfide zone had minimal contribution to FDEM measurements. The results of the study show that SP, VLF, and ERT methods provide significant information in localizing ore bodies. The survey revealed that the resistivity values obtained from ERT profile corroborate the FDEM, SP, and VLF from the area.  相似文献   

11.
A portion of an unconfined alluvial aquifer located in the Padana Plain (Italy) was characterized following an integrated hydro-geophysical approach. Initially an electrical resistivity tomography (ERT) survey was employed to localize the boundaries of a modest paleo-channel body and to design the installation of a groundwater monitoring network. Multilevel slug-tests were performed to estimate the aquifer’s saturated hydraulic conductivities. Determined permeability values together with electrical resistivity data were correlated. The correlation resulted in a site specific bi-logarithmic linear relationship. Based on this relationship, punctually determined hydraulic conductivities were spatially extended over the studied flow domain. Finally, continuously measured piezometric heads were used to calibrate a 3D flow model. Sensitivity analysis was performed to confirm the reliability of the reconstructed permeability field, as well as, to assess the minimum number of direct measurements needed to safely characterize the selected aquifer portion. The integration of the ERT survey results with the classical hydrogeological tests can be conveniently applied to constrain the permeability field during flow model calibration. Although the applicability of the determined relationship is site specific, the followed procedure is useful especially when there is a need to optimize the available resources and in case of small-scale pilot studies.  相似文献   

12.
现阶段适用于天然气水合物资源开采过程获得其空间分布变化的现场监测技术仍不完善.以电阻率层析成像(ERT)技术为基础,研发一套新的ERT阵列(由两组平行的垂向电极组合而成,每组阵列有24个环形电极)应用于水合物储层动态变化监测模拟实验.通过开展物理模拟实验,采用新的E RT方法对水合物生成过程进行了动态监测,并分析了动态...  相似文献   

13.
Rising damp and other moisture movements through porous stone and rock are known to cause weathering and deterioration, as noted in a range of recent field and laboratory studies. However, relatively little is known about the behaviour of moisture within a porous stone under realistic conditions because of lack of suitable monitoring methods. This paper has two main aims: firstly, to evaluate different electrical (resistivity and capacitance) methods to monitor subsurface and surface moisture regimes and, secondly, to use these methods to monitor the movement of water by capillary rise in a sandstone block under (a) conditions of constant moisture ingress at the base and (b) an enhanced drying regime with and without constant moisture ingress at the base. Our results indicate that, for electrical resistance tomography (ERT) measurements on a sandstone block, medical electrodes provide more reliable contact with the stone than spring-loaded pointed metal electrodes, and that the combination of ERT and handheld moisture meters gives a realistic picture of moisture movements within the block. The capillary rise and drying experiments reveal complex moisture movement over time and space. Under conditions of constant moisture supply, accelerated drying results in maintained or enhanced capillary rise. These findings are presented to further our understanding of the behaviour of moisture within porous sandstone.  相似文献   

14.
The coastal aquifer of the Plio-Quaternary delta sediment deposits of the Vélez river (province of Málaga, Spain) presents a highly irregular basement morphology and widely varying fill thickness (10–80 m between neighbouring sectors). The basin, which is tectonically controlled, is filled with lutite facies alternating with channel-filling rudites. This detrital aquifer is affected by seasonal seawater intrusion–extrusion processes due to increasing withdrawal of groundwater for human consumption and irrigation during dry periods.A study was performed to improve the hydrogeological knowledge of this coastal aquifer system. The study examined the morphology of the impervious substratum, the facies distribution and the position of the seawater wedge. For this purpose, an Electrical Resistivity Tomography (ERT) geophysical technique was used and the tomographic data were calibrated using geological observations and borehole studies. An analysis was carried out to compare the direct information obtained from the 35 boreholes with the indirect data corresponding to the four electrical tomography profiles. In the study, over 9660 resistivity data points were processed.The ERT profiles perfectly corroborated the information derived from the boreholes. The profiles made it possible to detect thickness changes, lithological changes and the presence of faults. Moreover, from a hydrogeologic standpoint, this research technique is capable of detecting the position of the phreatic level and, in coastal aquifers such as the one examined in this study, the possible horizontal or vertical penetration of seawater intrusion. Therefore, the electrical geophysical prospecting based on ERT can be highly useful in areas lacking sufficient geological information and/or mechanical borehole data.  相似文献   

15.
Two geophysical techniques were integrated to map the groundwater aquifers on complex geological settings, in the crystalline basement terrain in northeast Nuba Mountains. The water flow is structurally controlled by the northwest–southeast extensional faults as one of several in-situ deformational patterns that are attributed to the collision of the Pan-African oceanic assemblage of the Nubian shield against the pre-Pan African continental crust to the west. The structural lineaments and drainage systems have been enhanced by the remote sensing technique. The geophysical techniques used are: vertical electrical soundings (VES) and electrical resistivity tomography (ERT), in addition to hydraulic conductivity measurements. These measurements were designed to overlap in order to improve the producibility of the geophysical data and to provide a better interpretation of the hydrogeological setting of the aquifer complex structure. Smooth and Block inversion schemes were attempted for the observed ERT data to study their reliability in mapping the different geometries in the complex subsurface. The VES data was conducted where ERT survey was not accessible, and inverted smoothly and merged with the ERT in the 3D resistivity grid. The hydraulic conductivity was measured for 42 water samples collected from the distributed dug wells in the study area; where extremely high saline zones were recorded and have been compared to the resistivity values in the 3D model.  相似文献   

16.
Recently, the electrical resistivity tomography (ERT) technique has been increasingly applied to underground cavity detection filled with groundwater and/or clay. In this study, an ERT survey was conducted to examine the spatial distribution and shape of underground cavities in a karst area in Korea. Numerical ERT modeling and inversion were carried out to select appropriate field survey parameters. Two geological structures, similar to those that exist in the field survey area, were modeled: a sinkhole model and a vein-type structure. Electrode configurations using pole–pole, pole–dipole, dipole–pole, and dipole–dipole arrays were tested with the two geologic models and compared. The numerical modeling showed that the resistivity distribution of the ERT tomogram using the pole–dipole array produced the best representation of the two models. The pole–dipole and pole–pole array configurations were applied in an ERT field survey using six boreholes. The field ERT results show that cavity areas filled with clay or groundwater appeared as low-resistivity anomalies in the limestone formation. This was particularly evident in the inclined vein-type structures attributed to fracture zones, where the field data were similar to the modeling results. Therefore, the ERT technique could be effectively used for detecting underground limestone cavities under similar geological conditions as those at our study area.  相似文献   

17.
利用ERT数据推求非均质多孔介质渗透系数初探   总被引:2,自引:0,他引:2  
高密度电阻率成像法(ERT)能通过改变间距来对不同尺度上的地质体特征进行描述,近年来广泛地应用于地质、工程等领域。本文从电流场和渗流场的相似性出发来研究电阻率和渗透系数之间的关系,简要介绍了利用ERT技术所得的电阻率数据推求渗透系数的基本原理,并利用张家港大新和塘桥两处的ERT测量数据推求出渗透系数。与两地抽水试验结果和岩性取样分析的结果分别进行对比,结果较为吻合。  相似文献   

18.
Subsurface geophysical surveys were carried out using a large range of methods in an unconfined sandstone aquifer in semiarid south-western Niger for improving both the conceptual model of water flow through the unsaturated zone and the parameterization of numerical a groundwater model of the aquifer. Methods included: electromagnetic mapping, electrical resistivity tomography (ERT), resistivity logging, time domain electromagnetic sounding (TDEM), and magnetic resonance sounding (MRS). Analyses of electrical conductivities, complemented by geochemical measurements, allowed us to identify preferential pathways for infiltration and drainage beneath gullies and alluvial fans. The mean water content estimated by MRS (13%) was used for computing the regional groundwater recharge from long-term change in the water table. The ranges in permeability and water content obtained with MRS allowed a reduction of the degree of freedom of aquifer parameters used in groundwater modelling.  相似文献   

19.
We have jointly applied microwave remote sensing imaging and ground-based geophysical methodologies for investigating ground deformation. In particular, the Differential Interferometric Synthetic Aperture Radar (DInSAR) technique referred to as Small BAseline Subset (SBAS) algorithm and the Electrical Resistivity Tomography (ERT) method have been applied. The former is a tool for investigating large areas, allowing us to detect deformation phenomena and to analyse their spatial patterns and temporal evolution; the latter permits us to reconstruct, with high spatial resolution, the geometry of near-surface geological structures and to estimate the electrical resistivity of outcropping terrains. The starting point of our analysis has been a DInSAR survey carried out on an area of about 400 km2 centred around the town of Potenza (Basilicata region, Italy), for which SAR data acquired by the ERS-1/2 sensors in the time interval 1992–2000 were available. The DInSAR analysis allowed us to detect an unknown ground deformation effect which involves the urban area of Satriano di Lucania, located close to Potenza. An on-site ERT survey was then carried out in order to characterize in detail the physical properties of the terrains involved in the main deformation pattern detected via the DInSAR processing. The integration of the DInSAR and ERT measurements permitted us to investigate areas where the deformation have space-variant characteristics and allowed us to formulate a hypothesis on the origin of the detected displacement processes that, although not fully conclusive, is consistent with the overall DInSAR and ERT analysis.  相似文献   

20.
霍吉祥  宋汉周 《岩土力学》2015,36(Z2):57-63
近些年来地下水中多组分反应-运移模型在地球科学及环境领域开始得到应用,但其求解较为复杂,为了提高计算效率,可以采用去耦合化方法处理,从而使模型求解得到简化。针对自然界中广泛存在的非均质地质体,提出该类条件下的去耦合化方法,即根据水-岩间、水溶组分间反应的不同,将整个研究区划分为若干子区域,获得对应的去耦合化矩阵。对化学场中各子区域间相邻边界进行设定,达到简化模型求解的目的。最后,以一维非均质介质中基于热力学平衡的反应-运移问题作为算例,基于以上方法进行求解,并与该算例经PHAST软件所示的结果较为一致。结果表明,基于去耦合化方法获得的各离子浓度随时间演变和沿空间分布特征与PHAST所示的结果较为一致,显示该方法在非均质区域模拟溶质运移等方面具有较好的适用性。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏