1.
This paper presents a statistical performance analysis of a semi‐active structural control system for suppressing the vibration response of building structures during strong seismic events. The proposed semi‐active mass damper device consists of a high‐frequency mass damper with large stiffness, and an actively controlled interaction element that connects the mass damper to the structure. Through actively modulating the operating states of the interaction elements according to pre‐specified control logic, vibrational energy in the structure is dissipated in the mass damper device and the vibration of the structure is thus suppressed. The control logic, categorized under active interaction control, is defined directly in physical space by minimizing the inter‐storey drift of the structure to the maximum extent. This semi‐active structural control approach has been shown to be effective in reducing the vibration response of building structures due to specific earthquake ground motions. To further evaluate the control performance, a Monte Carlo simulation of the seismic response of a three‐storey steel‐framed building model equipped with the proposed semi‐active mass damper device is performed based on a large ensemble of artificially generated earthquake ground motions. A procedure for generating code‐compatible artificial earthquake accelerograms is also briefly described. The results obtained clearly demonstrate the effectiveness of the proposed semi‐active mass damper device in controlling vibrations of building structures during large earthquakes. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

2.
为了研究新型电磁惯性质量阻尼器(Electromagnetic Inertial Mass Damper,EIMD)应用于偏心高层结构振动控制工程的可行性,鉴于半主动控制技术的优点,基于LQR主动控制算法,提出一种可行的EIMD-偏心高层结构半主动控制策略,同时研究EIMD在结构每层中安装位置不同对于控制偏心高层结构扭转反应的影响。以一个实体24层偏心高层结构作为研究对象验证地震作用下所提控制策略的有效性,仿真结果表明:(1)所提半主动控制策略基本能够达到主动控制对于结构振动反应分量的控制效果;(2)当采用半主动控制策略时,调整EIMD的安装位置对于偏心高层结构转角和转角加速度反应有着较好的控制效果。  相似文献   

3.
Vibration mitigation using smart, reliable and cost‐effective mechanisms that requires small activation power is the primary objective of this paper. A semi‐active controller‐based neural network for base‐isolation structure equipped with a magnetorheological (MR) damper is presented and evaluated. An inverse neural network model (INV‐MR) is constructed to replicate the inverse dynamics of the MR damper. Next, linear quadratic Gaussian (LQG) controller is designed to produce the optimal control force. Thereafter, the LQG controller and the INV‐MR models are linked to control the structure. The coupled LQG and INV‐MR system was used to train a semi‐active neuro‐controller, designated as SA‐NC, which produces the necessary control voltage that actuates the MR damper. To evaluate the proposed method, the SA‐NC is compared to passive lead–rubber bearing isolation systems (LRBs). Results revealed that the SA‐NC was quite effective in seismic response reduction for wide range of motions from moderate to severe seismic events compared to the passive systems. In addition, the semi‐active MR damper enjoys many desirable features, such as its inherent stability, practicality and small power requirements. The effectiveness of the SA‐NC is illustrated and verified using simulated response of a six‐degree‐of‐freedom model of a base‐isolated building excited by several historical earthquake records. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

4.
Critical non‐structural equipments, including life‐saving equipment in hospitals, circuit breakers, computers, high technology instrumentations, etc., are vulnerable to strong earthquakes, and the failure of these equipments may result in a heavy economic loss. In this connection, innovative control systems and strategies are needed for their seismic protections. This paper presents the performance evaluation of passive and semi‐active control in the equipment isolation system for earthquake protection. Through shaking table tests of a 3‐story steel frame with equipment on the first floor, a magnetorheological (MR)‐damper together with a sliding friction pendulum isolation system is placed between the equipment and floor to reduce the vibration of the equipment. Various control algorithms are used for this semi‐active control studies, including the decentralized sliding mode control (DSMC) and LQR control. The passive‐on and passive‐off control of MR damper is used as a reference for the discussion on the control effectiveness. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

5.
6.
Passive and semi‐active tuned mass damper (PTMD and SATMD) building systems are proposed to mitigate structural response due to seismic loads. The structure's upper portion self plays a role either as a tuned mass passive damper or a semi‐active resetable device is adopted as a control feature for the PTMD, creating a SATMD system. Two‐degree‐of‐freedom analytical studies are employed to design the prototype structural system, specify its element characteristics and effectiveness for seismic responses, including defining the resetable device dynamics. The optimal parameters are derived for the large mass ratio by numerical analysis. For the SATMD building system the stiffness of the resetable device design is combined with rubber bearing stiffness. From parametric studies, effective practical control schemes can be derived for the SATMD system. To verify the principal efficacy of the conceptual system, the controlled system response is compared with the response spectrum of the earthquake suites used. The control ability of the SATMD scheme is compared with that of an uncontrolled (No TMD) and an ideal PTMD building systems for multi‐level seismic intensity. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
Floor isolation is an alternative to base isolation for protecting a specific group of equipment installed on a single floor or room in a fixed‐base structure. The acceleration of the isolated floor should be mitigated to protect the equipment, and the displacement needs to be suppressed, especially under long‐period motions, to save more space for the floor to place equipment. To design floor isolation systems that reduce acceleration and displacement for both short‐period and long‐period motions, semi‐active control with a newly proposed method using the linear quadratic regulator (LQR) control with frequency‐dependent scheduled gain (LQRSG) is adopted. The LQRSG method is developed to account for the frequency characteristics of the input motion. It updates the control gain calculated by the LQR control based on the relationship between the control gain and dominant frequency of the input motion. The dominant frequency is detected in real time using a window method. To verify the effectiveness of the LQRSG method, a series of shake table tests is performed for a semi‐active floor isolation system with rolling pendulum isolators and a magnetic‐rheological damper. The test results show that the LQRSG method is significantly more effective than the LQR control over a range of short‐period and long‐period motions. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

8.
A direct finite element method for nonlinear earthquake analysis of 2‐dimensional dam–water–foundation rock systems has recently been presented. The analysis procedure uses standard viscous‐damper absorbing boundaries to model the semi‐unbounded foundation‐rock and fluid domains and specifies the seismic input as effective earthquake forces at these boundaries. Presented in this paper is a generalization of the direct finite element method with viscous‐damper boundaries to 3‐dimensional dam–water–foundation rock systems. Step‐by‐step procedures for determining the effective earthquake forces starting from a ground motion specified at a control point on the foundation‐rock surface is developed, and several numerical examples are computed and compared with independent benchmark solutions to demonstrate the effectiveness of the analysis procedure for modeling 3‐dimensional systems.  相似文献   

9.
In this paper a predictive control method especially suitable for the control of semi‐active friction dampers is proposed. By keeping the adjustable slip force of a semi‐active friction damper slightly lower than the critical friction force, the method allows the damper to remain in its slip state throughout an earthquake of arbitrary intensity, so the energy dissipation capacity of the damper can be improved. The proposed method is formulated in a discrete‐time domain and cast in the form of direct output feedback for easy control implementation. The control algorithm is able to produce a continuous and smooth slip force for a friction damper and thus avoid exerting the high‐frequency structural response that usually exists in structures with conventional friction dampers. Using a numerical study, the control performance of a multiple degrees of freedom (DOF) structural system equipped with passive friction dampers and semi‐active dampers controlled by the proposed method are compared. The numerical case shows that by merely using a single semi‐active friction damper and a few sensors, the proposed method is able to achieve better acceleration reduction than the case using multiple passive dampers. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

10.
A wall‐type friction damper is newly proposed in this paper to improve the performance of reinforced concrete (RC) framed structures under earthquake loads. Traditionally, the damper was generally invented as a brace‐type member. However, it has been seen to cause problems in the RC frame structures in that concrete is apt to be damaged in the connection regions of the RC member and the brace‐type damper under earthquake loads. The proposed wall‐type damper has an advantage in the retrofit of RC structures. The system consists of a Teflon® slider and a RC wall. The damper is also designed to control normal pressures acting on a frictional slider. The numerical applications show that the proposed damper can be effective in mitigating the seismic responses of RC frame structures and reducing the damage to RC structural members. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

11.
磁流变阻尼器对高层建筑风振反应的半主动控制   总被引:21,自引:3,他引:21  
本文探讨了磁流变阻尼器在高层建筑风振控制中的应用,在经典线性最优控制理论的基础上,根据磁流变阻尼器的特点,提出了一种新型的半主动控制策略,应有该方法对一40层的钢结构的风振反应进行了计算机模拟,结果表明,采用磁流变阻尼器对高层建筑进行半主动控制的能够有效减小结构的风振反应。  相似文献   

12.
The Friction Pendulum System (FPS) isolator is commonly used as a base isolation system in buildings. In this paper, a new tunable FPS (TFPS) isolator is proposed and developed to act as a semi‐active control system by combining the traditional FPS and semi‐active control concept. Theoretical analysis and physical tests were carried out to investigate the behavior of the proposed TFPS isolator. The experimental and theoretical results were in good agreement, both suggesting that the friction force of the TFPS isolator can be tuned to achieve seismic isolation of the structure. A series of numerical simulations of a base‐isolated structure equipped with the proposed TFPS isolator and subjected to earthquake ground motions were also conducted. In the analyses, the linear quadratic regulator (LQR) method was adopted to control the friction force of the proposed TFPS, and the applicability and effectiveness of the TFPS in controlling the structure's seismic responses were investigated. The simulation results showed that the TFPS can reduce the displacement of the isolation layer without significantly increasing the floor acceleration and inter‐story displacement of the superstructure, confirming that the TFPS can effectively control a base‐isolated structure under earthquake ground motions.  相似文献   

13.
A magneto‐rheological (MR) damper is a semi‐active device where the damper force capacity is controlled by varying the input current into the damper. In this paper, the dynamics of MR dampers associated with variable current input is studied. Electromagnetic theory is used to model the dynamics of an MR damper including the eddy current effect and the nonlinear hysteretic behavior of damper material magnetization. A nonlinear differential equation that relates the input current to the damper with a constant equivalent current is proposed. The nonlinear differential equation is combined with the Maxwell Nonlinear Slider (MNS) model to create the variable current MNS model to predict the damper force under variable input current and random damper displacement loading. The model is evaluated by comparing the predicted response of a large‐scale MR damper to the measured damper response from experiments. The experiments include a real‐time hybrid simulation of a 3‐story building structure with a large‐scale MR damper subjected to the design earthquake. The exceptional agreement observed between the predicted and experimental results illustrate the robustness and the accuracy of the variable current MNS model. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

14.
Magneto‐rheological (MR) dampers are a promising device for seismic hazard mitigation because their damping characteristics can be varied adaptively using an appropriate control law. During the last few decades researchers have investigated the behavior of MR dampers and semi‐active control laws associated with these types of dampers for earthquake hazard mitigation. A majority of this research has involved small‐scale MR dampers. To investigate the dynamic behavior of a large‐scale MR damper, characterization tests were conducted at the Lehigh Network for Earthquake Engineering Simulation equipment site on large‐scale MR dampers. A new MR damper model, called the Maxwell Nonlinear Slider (MNS) model, is developed based on the characterization tests and is reported in this paper. The MNS model can independently describe the pre‐yield and post‐yield behavior of an MR damper, which makes it easy to identify the model parameters. The MNS model utilizes Hershel–Bulkley visco‐plasticity to describe the post‐yield non‐Newtonian fluid behavior, that is, shear thinning and thickening behavior, of the MR fluid that occurs in the dampers. The predicted response of a large‐scale damper from the MNS model along with that from existing Bouc–Wen and hyperbolic tangent models, are compared with measured response from various experiments. The comparisons show that the MNS model achieves better accuracy than the existing models in predicting damper response under cyclic loading. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
基于加速度反馈的结构地震反应半主动MR阻尼控制试验   总被引:11,自引:1,他引:11  
本文针对安装有半主动磁流变阻尼器(MR damper)的一座二层模型结构进行了抗震振动台试验研究,通过采用基于加速度反馈控制策略的两种半主动控制算法进行了在各种地震动作用下模型结构的半主动控制的抗震试验研究,并进行了Passive-on和Passive-off两种被动控制的试验研究。试验结果表明,MR阻尼器作为一种半主动控制装置可以有效地控制结构的峰值位移和均方差反应,且半主动控制对结构顶层的峰值位移和均方差的控制效果均优于两种被动控制方法。因此,本文提出的两种半主动控制算法都是有效的,并宜于实现。  相似文献   

16.
A semi‐active fuzzy control strategy for seismic response reduction using a magnetorheological (MR) damper is presented. When a control method based on fuzzy set theory for a structure with a MR damper is used for vibration reduction of a structure, it has an inherent robustness, and easiness to treat the uncertainties of input data from the ground motion and structural vibration sensors, and the ability to handle the non‐linear behavior of the structure because there is no longer the need for an exact mathematical model of the structure. For a clipped‐optimal control algorithm, the command voltage of a MR damper is set at either zero or the maximum level. However, a semi‐active fuzzy control system has benefit to produce the required voltage to be input to the damper so that a desirable damper force can be produced and thus decrease the control force to reduce the structural response. Moreover, the proposed control strategy is fail‐safe in that the bounded‐input, bounded‐output stability of the controlled structure is guaranteed. The results of the numerical simulations show that the proposed semi‐active control system consisting of a fuzzy controller and a MR damper can be beneficial in reducing seismic responses of structures. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

17.
This paper summarizes the relevant results of the design, construction, testing, and implementation of a nominal 120 kN magnetorheological damper developed to control a free‐plan tall building in Santiago, Chile, equipped with two 160‐ton tuned masses. Cyclic as well as hybrid simulation tests were performed on the prototype damper. Global building responses using measured MR properties showed good correlation with analytical estimations. Also, a proposed physical controller for the MR damper was validated through hybrid and building pull‐back tests. Its performance is essentially equivalent to that of an LQR controller, but the information needed in its implementation is considerably less. Pull‐back tests of 10 cm amplitude were performed on one mass along the flexible edge of the building and its response controlled using the passive and controlled modes of the MR damper. The MR damper was capable of controlling the TM displacements very effectively, as well as the simulated building response for different ground motions and harmonic excitation. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

18.
Semi‐active control of buildings and structures for earthquake hazard mitigation represents a relatively new research area. Two optimal displacement control strategies for semi‐active control of seismic response of frame structures using magnetorheological (MR) dampers or electrorheological (ER) dampers are proposed in this study. The efficacy of these displacement control strategies is compared with the optimal force control strategy. The stiffness of brace system supporting the smart damper is also taken into consideration. An extensive parameter study is carried out to find the optimal parameters of MR or ER fluids, by which the maximum reduction of seismic response may be achieved, and to assess the effects of earthquake intensity and brace stiffness on damper performance. The work on example buildings showed that the installation of the smart dampers with proper parameters and proper control strategy could significantly reduce seismic responses of structures, and the performance of the smart damper is better than that of the common brace or the passive devices. The optimal parameters of the damper and the proper control strategy could be identified through a parameter study. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

19.
A direct finite element method is presented for nonlinear earthquake analysis of interacting dam–water–foundation rock systems. The analysis procedure applies viscous damper absorbing boundaries to truncate the semi‐unbounded fluid and foundation‐rock domains and specifies at these boundaries effective earthquake forces determined from the design ground motion defined at a control point on the free surface. The analysis procedure is validated numerically by computing the frequency response functions and transient response of an idealized dam–water–foundation rock system and comparing with results from the substructure method. Because the analysis procedure is applicable to nonlinear systems, it allows for modeling of concrete cracking, as well as sliding and separation at construction joints, lift joints, and at concrete–rock interfaces. Implementation of the procedure is facilitated by commercial finite element software with nonlinear material models that permit modeling of viscous damper boundaries and specification of effective earthquake forces at these boundaries. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

20.
This paper proposes a semiactive control system to reduce the coupled lateral and torsional motions in asymmetric buildings subjected to horizontal seismic excitations. Magnetorheological (MR) dampers are applied as semiactive control devices and the control input determination is based on a clipped‐optimal control algorithm which uses absolute acceleration feedback. The performance of this method is studied experimentally using a 2‐story building model with an asymmetric stiffness distribution. An automated system identification methodology is implemented to develop a control‐oriented model which has the natural frequencies observed in the experimental system. The parameters for the MR damper model are identified using experimental data to develop an integrated model of the structure and MR dampers. To demonstrate the performance of this control system on the experimental structure, a shake table is used to reproduce an El Centro 1940 N–S earthquake as well as a random white noise excitation. The responses for the proposed control system are compared to those of passive control cases in which a constant voltage is applied to the MR damper. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   