There are numerous studies on the behavior of Unreinforced Masonry (URM) walls in both in‐plane (IP) and out‐of‐plane (OP) directions; however, few aimed at understanding the simultaneous contribution of these intrinsic responses during earthquakes. Undoubtedly, even a strong URM wall shows weakened capacity in the OP direction because of minor cracks and other damages in the IP direction, and this capacity reduction has not yet been accounted for in seismic codes. In this study, performance of three URM walls is evaluated by several numerical analyses in terms of the OP capacity reduction because of IP displacements and failure modes. Several parameters influencing the OP capacity have been studied including aspect ratio, roof boundary condition, IP displacement and IP loading patterns. The results indicate that reduction in the OP capacity of URM walls varies from negligible to very high depending on boundary conditions, IP failure mode and IP damage severity. Moreover, IP loading pattern is more important in walls with higher aspect ratios because of their IP failure modes. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

2.
This paper describes the results of an experimental and numerical study that focused on multi‐directional behavior of unreinforced masonry walls and established the requisite of the related proposed design equations. The tests were conducted following several sets of multi‐directional loading combinations imposed on the top plane of the wall along with considering monotonic and cyclic quasi‐static loading protocols. Various boundary conditions, representing possible wall–roof connections, were also considered for different walls to investigate the influence of rotation of the top plane of the wall on the failure modes. The results of the tests were recorded with a host of high precision data acquisition systems, showing three‐dimensional displacements of a grid on the surface of the wall. Finite element models of the walls are developed using the commercial software package ABAQUS/Explicit compiled with a FORTRAN subroutine (VUMAT) written by the authors. The experimental results were then used to validate the finite element models and the developed user‐defined material models. With the utility of validated models, a parametric study was performed on a set of parameters with dominant influence on the behavior of the wall system under in‐plane and out‐of‐plane loading combinations. The experimental and numerical results are finally used to investigate the adequacy of ASCE 41 empirical equations, and some insights and recommendations are made. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

3.
In modern unreinforced masonry buildings with stiff RC slabs, walls of the top floor are most susceptible to out‐of‐plane failure. The out‐of‐plane response depends not only on the acceleration demand and wall geometry but also on the static and kinematic boundary conditions of the walls. This paper discusses the influence of these boundary conditions on the out‐of‐plane response through evaluation of shake table test results and numerical modelling. As a novum, it shows that the in‐plane response of flanking elements, which are orthogonal to the wall whose out‐of‐plane response is studied, has a significant influence on the vertical restraint at the top of the walls. The most critical configuration exists if the flanking elements are unreinforced masonry walls that rock. In this case, the floor slabs can uplift, and the out‐of‐plane load‐bearing walls loose the vertical restraint at the top. Numerical modelling confirms this experimentally observed behaviour and shows that slab uplift and the difference in base and top excitation have a strong influence on the out‐of‐plane response of the walls analysed. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

4.
An analytical model describing the flexural response of vertically spanning out‐of‐plane loaded unreinforced masonry walls is presented in this paper. The model is based on the second‐order Euler‐Bernoulli beam theory and captures important characteristics of the out‐of‐plane response of masonry walls that have been observed in experimental tests and from numerical studies but for which an analytical solution was still lacking: the onset and the evolution of cracking, the peak strength of the out‐of‐plane loaded walls, and the softening of the response due to P ?Δ effects. The model is validated against experimental results, and the comparison shows that the model captures both the prepeak and postpeak response of the walls. From the analytical model of the force‐displacement curve, a formula for the maximum out‐of‐plane strength of the walls is derived, which can be directly applied in engineering practice.  相似文献   

5.
Seismic response of unreinforced masonry (URM) buildings is largely influenced by nonlinear behavior of spandrels, which provide coupling between piers under in‐plane lateral actions. Seismic codes do not appropriately address modeling and strength verification of spandrels, adapting procedures originally proposed for piers. Therefore, research on spandrels has received significant attention in some earthquake‐prone countries, such as Italy and New Zealand. In the last years, the authors of this paper have performed both monotonic and cyclic in‐plane lateral loading tests on full‐scale masonry walls with single opening and different spandrel types. Those tests were carried out in a static fashion and with displacement control. In this paper, experimental outcomes for two as‐built specimens are presented and compared with those obtained in the past for another as‐built specimen with a wooden lintel above the opening. In both newly tested specimens, the masonry above the opening was supported by a shallow masonry arch. In one of those specimens, a reinforced concrete (RC) bond beam was realized on top of the spandrel, resulting in a composite URM‐RC spandrel. Then, the influence of spandrel type is analyzed in terms of observed damage, force–drift curves, and their bilinear idealizations, which allowed to compare displacement ductility and overstrength of wall specimens. Furthermore, effects of rocking behavior of piers are identified, highlighting their relationship with hysteretic damping and residual drifts. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
A simplified numerical model was used to investigate the out‐of‐plane seismic response of vertically spanning unreinforced masonry (URM) wall strips. The URM wall strips were assumed to span between two flexible diaphragms and to develop a horizontal crack above the wall mid‐height. Three degrees of freedom were used to accommodate the wall displacement at the crack height and at the diaphragm connections, and the wall dynamic stability was studied. The equations of dynamic motion were obtained using principles of rocking mechanics of rigid bodies, and the formulae were modified to include semi‐rigid wall behaviour. Parametric studies were conducted that included calculation of the wall response for different values of diaphragm stiffness, wall properties, applied overburden, wall geometry and earthquake ground motions. The results of the study suggest that stiffening the horizontal diaphragms of typical low‐rise URM buildings will amplify the out‐of‐plane acceleration demand imposed on the wall and especially on the wall–diaphragm connections. It was found that upper‐storey walls connected to two flexible diaphragms had reduced stability for applied earthquake accelerograms having dominant frequency content that was comparable with the frequency of the diaphragms. It was also found that the applied overburden reduced wall stability by reducing the allowable wall rotations. The results of this study suggest that the existing American Society of Civil Engineers recommendations for assessment of vertically spanning walls overestimate the stability of top‐storey walls in multi‐storey buildings in high‐seismic regions or for walls connected to larger period (less stiff) diaphragms. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

7.
The role of masonry infills in the seismic behavior of reinforced concrete buildings has been widely studied in terms of their strength and stiffness contribution in the in‐plane (IP) direction, while fewer studies have been carried out on their response and modeling in the out‐of‐plane (OOP) direction. In this paper, the state of the art in code and literature provisions regarding infills' OOP capacity and seismic demand is presented, together with a review of the experimental tests that have been carried out to investigate infills' OOP behavior and the effects of IP‐OOP interaction. This review aims to collect an experimental database that is used to evaluate the effectiveness of literature and code provisions and to propose a semiempirical approach both for predicting infills' OOP strength, stiffness, and displacement capacity and for modeling the effects of IP displacement demand on OOP behavior and vice versa. Then, the state of the art on modeling of infills' OOP behavior and IP‐OOP interaction is presented together with a new macro model based on the proposed formulations and conceived to represent the IP and OOP behavior by taking into account the mutual interaction effects. Finally, the proposed model is used for an example application on two case‐study buildings, showing the effects of taking into account or neglecting the IP‐OOP interaction phenomena.  相似文献   

8.
An experimental programme was conducted in which eight full‐scale unreinforced masonry walls were subjected to cyclic face loading using a system of airbags. Of the eight walls, six contained a window opening and four were subjected to vertical pre‐compression. Combined supports at the vertical and horizontal edges ensured that under face loading the walls underwent two‐way bending. The test walls were found to possess good post‐peak strength and displacement capacity as well as reasonable energy dissipation characteristics. Significant strength and stiffness degradation and non‐symmetry of strength in the positive and negative displacement directions were also evident. Discussion of the causes of the aforementioned trends and their implications towards the seismic response of masonry walls is provided. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

9.
Eight half‐scale brick masonry walls were tested to study two important aspects of confined masonry (CM) walls related to its seismic behavior under in‐plane and out‐of‐plane loads. Four solid wall specimens tested to investigate the role of type of interface between the masonry and tie‐columns, such as toothing varying from none to every course. The other four specimens with openings were tested to study the effectiveness of various strengthening options around opening to mitigate their negative influence. In the set of four walls, one wall was infilled frame while the other three were CM walls of different configurations. The experimental results were further used to determine the accuracy of various existing models in predicting the in‐plane response quantities of CM walls. Confined masonry walls maintained structural integrity even when severely damaged and performed much better than infill frames. No significant effect of toothing details was noticed although toothing at every brick course was preferred for better post‐peak response. For perforated walls, provision of vertical elements along with continuous horizontal bands around openings was more effective in improving the overall response. Several empirical and semi‐empirical equations are available to estimate the lateral strength and stiffness of CM walls, but those including the contribution of longitudinal reinforcement in tie‐columns provided better predictions. The available equations along with reduction factors proposed for infills could not provide good estimates of strength and stiffness for perforated CM walls. However, recently proposed relations correlating strength/stiffness with the degree of confinement provided reasonable predictions for all wall specimens. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

10.
A simple constitutive model is proposed for an in‐plane numerical analysis of unreinforced masonry structures, which are subject to cyclic loading, by using explicit dynamic procedures. The proposed model is implemented by using two‐dimensional plane‐stress finite elements. Three different constitutive relations that are based on the total strain in the global material system are used. Cracking and crushing are controlled through normal strains, whereas shear is controlled through shear strain. Separate hysteretic rules are adopted for each mode of damage. A numerical analysis of masonry walls that are subject to cyclic loading has demonstrated that the use of explicit procedures in conjunction with the proposed model results in an acceptable accuracy when compared with the experimental results. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

11.
This paper addresses the problem of assessing the seismic resistance of brick masonry walls subject to out‐of‐plane bending. A simplified linearized displacement‐based procedure is presented along with recommendations for the selection of an appropriate substitute structure in order to provide the most representative analytical results. A trilinear relationship is used to characterize the real nonlinear force–displacement relationship for unreinforced brick masonry walls. Predictions of the magnitude of support motion required to cause flexural failure of masonry walls using the linearized displacement‐based procedure and quasi‐static analysis procedures are compared with the results of experiments and non‐linear time‐history analyses. The displacement‐based procedure is shown to give significantly better predictions than the force‐based method. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

12.
This article presents a new mechanical model for the non‐linear force–displacement response of unreinforced masonry (URM) walls developing a flexural rocking mode including their displacement capacity. The model is based on the plane‐section hypothesis and a constitutive law for the masonry with zero tensile strength and linear elastic behaviour in compression. It is assumed that only the compressed part of the wall contributes to the stiffness of the wall and therefore the model accounts for a softening of the response due the reduction of the effective area. Stress conditions for limit states are proposed that characterise the flexural failure. The new model allows therefore linking local performance levels to global displacement capacities. The limit states criteria describe the behaviour of modern URM walls with cement mortar of normal thickness and clay bricks. The model is validated through comparison of local and global engineering demand parameters with experimental results. It provides good prediction of the effective stiffness, the force capacity and the displacement capacity of URM walls at different limit states. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

13.
The seismic performance of unreinforced masonry structures is strongly associated with the interaction between in‐plane and out‐of‐plane mechanisms. The seismic response of these structures has been thoroughly investigated by means of experimental testing, analytical procedures, and computational approaches. Within the framework of the numerical simulations, models based on the finite element method provide a good prediction of the seismic performance of unreinforced masonry structures. However, they usually require a high computational cost and advanced user expertise to define appropriate mechanical properties and to interpret the numerical results. Because of these limitations, simplified models for practical applications have been developed during the last decades. Despite this, a great number of these models focus mostly on the evaluation of the in‐plane response, assuming box (or integral) behavior of the structure. In this paper, a simplified macroelement modeling approach is used to simulate the seismic response of 2 masonry prototypes taking into consideration the combined in‐plane and out‐of‐plane action. The numerical investigations were performed in the static and dynamic fields by using pushover analyses and nonlinear dynamic analyses respectively. The latter is a novel implementation of a model previously developed for static analysis. The results obtained from this study are in good agreement with those provided by a detailed nonlinear continuum FE approach, demonstrating the applicability of this macroelement model with a significant reduction of the computational cost.  相似文献   

14.
The in‐plane cyclic behaviour of three types of unreinforced clay masonry was characterized by means of laboratory tests on full‐scale specimens. The masonry walls were assembled with various bonding arrangements (head joints made with mortar pockets, dry head joints with mechanical interlocking, thin‐layer mortar bed joints), which are not yet inserted in seismic codes. Experimental behaviour was modelled with an analytical hysteretic model able to predict lateral load–displacement curves in case of shear failure of the unreinforced walls. According to the experimental results and those of the selected analytical model, parametric study to evaluate the reduction in lateral strength demand produced by non‐linear behaviour in masonry walls, i.e. the load reduction factor was carried out by non‐linear dynamic analyses. The calculated values of the load reduction factor were modest. The differences in values found for the three masonry types, although consistent with them, were not great. This may indicate that, in the ultimate limit state, the type of masonry cannot significantly affect the behaviour of an entire building. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

15.
Masonry buildings are often characterized by geometric irregularities. In many cases, such buildings meet global regularity requirements provided by seismic codes, but they are composed by irregular walls with openings. The latter are masonry walls characterized by (i) openings of different sizes, (ii) openings misaligned in the horizontal and/or vertical direction, or (iii) a variable number of openings per story. An irregular layout of openings can induce not only a nonuniform distribution of gravity loads among masonry piers but also unfavorable damage localizations resulting in a premature collapse of the wall and hence a higher seismic vulnerability. This paper is aimed at providing a simplified methodology to assess the effects of irregularities on the in‐plane seismic capacity of unreinforced masonry (URM) walls with openings. To this end, a macroelement method was developed and validated through experimental results available in the literature. The proposed methodology was based on the quantification of wall irregularities by means of geometric indices and their effects on seismic capacity of URM walls with openings through both sensitivity and regression analyses. Sensitivity analysis was based on a high number of static pushover analyses and allowed to assess variations in key seismic capacity parameters. Regression analysis let to describe each capacity parameter under varying irregularity index, providing empirical models for seismic assessment of irregular URM walls with openings. The in‐plane seismic capacity was found to be significantly affected by wall irregularities, especially in the case of openings with different heights. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
The seismic assessment of the local failure modes in existing masonry buildings is currently based on the identification of the so‐called local mechanisms, often associated with the out‐of‐plane wall behavior, whose stability is evaluated by static force‐based approaches and, more recently, by some displacement‐based proposals. Local mechanisms consist of kinematic chains of masonry portions, often regarded as rigid bodies, with geometric nonlinearity and concentrated nonlinearity in predefined contact regions (unilateral no‐tension behavior, possible sliding with friction). In this work, the dynamic behavior of local mechanisms is simulated through multi‐body dynamics, to obtain the nonlinear response with efficient time history analyses that directly take into account the characteristics of the ground motion. The amplification/filtering effects of the structure are considered within the input motion. The proposed approach is validated with experimental results of two full‐scale shaking‐table tests on stone masonry buildings: a sacco‐stone masonry façade tested at Laboratório Nacional de Engenharia Civil and a two‐storey double‐leaf masonry building tested at European Centre for Training and Research in Earthquake Engineering (EUCENTRE). Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
An innovative solution for the seismic protection of existing masonry structures is proposed and investigated through shake table tests on a natural scale wall assemblage. After a former test series carried out without reinforcement, the specimen was retrofitted using Steel Reinforced Grout. The strengthening system comprises horizontal strips of ultra‐high strength steel cords, externally bonded to the masonry with hydraulic lime mortar, and connectors to transversal walls, applied within the thickness of the plaster layer. In order to assess the seismic performance of the retrofitted wall, natural accelerograms were applied with increasing intensity up to failure. Test results provide a deep understanding of the effectiveness of mortar‐based composites for improving the out‐of‐plane seismic capacity of masonry walls, in comparison with traditional reinforcements with steel tie‐bars. The structural implications of the proposed solution in terms of dynamic properties and damage development under earthquake loads are also discussed.Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

18.
Seismic assessment of existing unreinforced masonry buildings represents a current challenge in structural engineering. Many historical masonry buildings in earthquake regions were not designed to withstand seismic loading; thus, these structures often do not meet the basic safety requirements recommended by current seismic codes and need to be strengthened considering the results from realistic structural analysis. This paper presents an efficient modelling strategy for representing the nonlinear response of unreinforced masonry components under in‐plane cyclic loading, which can be used for practical and accurate seismic assessment of masonry buildings. According to the proposed strategy, generic masonry perforated walls are modelled using an equivalent frame approach, where each masonry component is described utilising multi‐spring nonlinear elements connected by rigid links. When modelling piers and spandrels, nonlinear springs are placed at the two ends of the masonry element for describing the flexural behaviour and in the middle for representing the response in shear. Specific hysteretic rules allowing for degradation of stiffness and strength are then used for modelling the member response under cyclic loading. The accuracy and the significant potential of the proposed modelling approach are shown in several numerical examples, including comparisons against experimental results and the nonlinear dynamic analysis of a building structure. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

19.
This study focuses on the seismic safety evaluation of masonry buildings in Turkey for in‐plane failure modes using fragility curves. Masonry buildings are classified and a set of fragility curves are generated for each class. The major structural parameters in the classification of masonry buildings are considered as the number of stories, load‐bearing wall material, regularity in plan and the arrangement of walls (required length, openings in walls, etc.), in accordance with the observations from previous earthquakes and field databases. The fragility curves are generated by using time history (for demand) and pushover (for capacity) analyses. From the generated sets of fragility curves, it is observed that the damage state probabilities are significantly influenced from the number of stories and wall material strength. In the second stage of the study, the generated fragility curves are employed to estimate the damage of masonry buildings in Dinar after the 1995 earthquake. The estimated damage by fragility information is compared with the inspected visual damage as assessed from the Damage Evaluation Form. For the quantification of fragility‐based damage, a single‐valued index, named as ‘vulnerability score’ (VS), is proposed. There seems to be a fair agreement between the two damage measures. In addition to this, decisions regarding the repair or demolition of masonry buildings in Dinar due to visual damage inspection are on comparable grounds with the relative measure obtained from VS of the same buildings. Hence, the fragility‐based procedure can provide an alternative for the seismic safety evaluation of masonry buildings in Turkey. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

20.
This paper presents the results on shaking table tests of half‐scale brick walls performed to investigate the effectiveness of newly developed Cu–Al–Mn superelastic alloy (SEA) bars in retrofitting of historical masonry constructions. Problems associated with conventional steel reinforcing bars lie in degradation of stiffness and strength, or pinching phenomena, under cyclic loading, and presence of large residual cracks in structures during and after intense earthquakes. This paper attempts to resolve the problems by applying newly developed Cu–Al–Mn SEA bars, characterized by large recovery strain, low material cost, and high machinability, as partial replacements for steel bars. Sets of unreinforced, steel reinforced, and SEA‐reinforced specimens are subjected to scaled earthquake excitations in out‐of‐plane direction. Whereas steel‐reinforced specimens showed large residual inclinations, SEA‐reinforced specimens resulted in stable rocking response with slight residual inclinations. Corresponding nonlinear finite element (FE) models are developed to simulate the experimental observations. The FE models are further used to examine the sensitivity of the response with respect to the variations in experimental conditions. Both the experimental and numerical results demonstrate the superiority of Cu–Al–Mn SEA bars to conventional steel reinforcing bars in avoiding pinching phenomena. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   