首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 929 毫秒
1.
Shaking table tests are performed on a one‐bay one‐story steel frame with superelastic Cu–Al–Mn shape memory alloy (SMA) tension braces. The frame is subjected to a series of scaled ground motions recorded during the 1995 Kobe earthquake, Japan. The test results demonstrate that the SMA braces are effective to prevent residual deformations and pinching. It is also shown that the time history responses observed from the shaking table tests agree well with the numerical predictions using a rate‐independent piecewise‐linear constitutive model calibrated to the quasi‐static component tests of the SMA braces. This suggests that the loading rate dependence of Cu–Al–Mn SMAs as well as the modeling error due to the piecewise linear approximation can be neglected in capturing the global response of the steel frame. Numerical simulations under a suite of near‐fault ground motion records are further performed using the calibrated analytical models to demonstrate the effectiveness of the SMA braces when the variability of near‐fault ground motions is taken into account. A stopper, or a deformation restraining device, is also proposed to prevent premature fracture of SMA bars in unexpectedly large ground motions while keeping the self‐centering capability in moderate to large ground motions. The effectiveness of the stopper is also demonstrated in the quasi‐static component and shaking table tests. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

2.
We present the results of the quasi‐static cyclic tensile tests of Cu–Al–Mn shape memory alloy (SMA) bars of 4 and 8 mm diameters to examine their superelasticity and other mechanical properties closely related to seismic applications. The present Cu–Al–Mn SMA bars have achieved the recovery strains of over 8% and the fracture strains of over 17%. Low‐cycle fatigue was observed in neither of the bars. The mechanical properties obtained from the test, along with the lower material cost and higher machinability than Ni–Ti SMAs, demonstrate the high potential of the present Cu–Al–Mn SMA bars to be used in seismic applications. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

3.
This experimental study investigates the effectiveness of crossed inclined bars (X‐bars) as joint shear reinforcement in exterior reinforced concrete beam–column connections under cyclic deformations. Test results of 20 joint subassemblages with various reinforcement ratios and arrangements including X‐bars in the joint area are presented. The X‐type, non‐conventional reinforcement is examined as the only joint reinforcement and in combination with common stirrups or vertical bars. The experimental results reported herein include full loading cycle curves, energy dissipation values and a categorization of the observed damage modes. Based on the comparisons between the overall hysteretic responses of the tested specimens, it is deduced that joints with X‐bars exhibited enhanced cyclic performance and improved damage mode since a distinct flexural hinge was developed in the beam–joint interface. Further, the combination of crossed inclined bars and stirrups in joint area resulted in enhanced hysteretic response and excellent performance capabilities of the specimens. However, in some specimens with X‐bars as the only joint shear reinforcement, the deformations of the bent anchorage of the beam's bars caused considerable damages at the back of the joint area. Discussion for a potential replacement of the joint stirrups with X‐type reinforcement in some cases of exterior joints is also included. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

4.
The seismic damages commonly observed on beam–column joints of old reinforced concrete structures, built with plain bars and without proper detailing, justifies the need to further study the behaviour of this type of structures. The response of these structures when loaded cyclically, as occurs during the earthquakes, is partially controlled by the bond properties between the reinforcing bars and the surrounding concrete. This paper presents the results of an experimental campaign of unidirectional cyclic tests carried out on six full‐scale beam–column joints built with plain bars. These joint specimens are representative of existing reinforced concrete structures, that is, built without adequate reinforcement detailing for seismic demands. For comparison, an additional specimen is built with deformed bars and tested. The seven specimens are designed and detailed to allow the investigation of the influence of bond properties, lapping of the longitudinal bars in columns and beams, bent‐up bars in the beams, slab contribution and concrete strength. The lateral force–drift relationships, global dissipated energy evolution, contribution of the joint, beams and columns to the global dissipated energy, ductility, equivalent damping, final damage observed, homogenized reinforced concrete damage index, displacement components, curvature evolutions and Eurocode requirements are presented and discussed. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
An existing two‐dimensional macroelement for reinforced concrete beam–column joints is extended to a three‐dimensional macroelement. The three‐dimensional macroelement for beam–column joints consists of six rigid interface plates and uniaxial springs for concrete, steel, and bond–slip, which model the inside of a beam–column joint. The mechanical models for the materials and the stiffness equation for the springs are also presented. To validate the model, we used test results from three slab–beam–column sub‐assemblages subjected to bi‐lateral cyclic load. It is revealed that the new joint model is capable of capturing the strength of beam–column joints and the bidirectional interaction in joint shear response, including the concentration of damage in the beam–column joint, the pinching nature in hysteretic behavior, the stiffness degradation, and strength deterioration resulting from cyclic and bidirectional loading. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

6.
The cyclic behavior of precast segmental concrete bridge columns with high performance (HP) steel reinforcing bars and that with conventional steel reinforcing bars as energy dissipation (ED) bars were investigated. The HP steel reinforcing bars are characterized by higher strength, greater ductility, and superior corrosion resistance compared with the conventional steel reinforcing bars. Three large‐scale columns were tested. One was designed with the HP ED bars and two with the conventional ED bars. The HP ED bars were fully bonded to the concrete. The conventional ED bars were fully bonded to the concrete for one column, whereas unbonded for a length to delay fracture of the bars and to increase energy dissipation for the other column. Test results showed that the column with the HP ED bars had greater drift capacity, higher lateral strength, and larger energy dissipation than that with fully bonded conventional ED bars. The column with unbonded conventional ED bars achieved the same drift capacity and similar energy dissipation capacity as that with the HP ED bars. All the three columns showed good self‐centering capability with residual drifts not greater than 0.4% drift. An analytical model referred to as joint bar‐slip rotation method for pushover analysis of segmental columns with ED bars is proposed. The model calculates joint rotation from the slip of the ED bars from two sides of the joint. Good agreement was found between analytical predictions and the envelope responses of the three columns. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

7.
The effectiveness of a rehabilitation method based on joint enlargement using prestressed steel angles to enhance the seismic behavior of damaged external reinforced concrete beam‐column joints was experimentally investigated. Three half‐scale joints having either non‐seismic or seismic reinforcement details were tested both before and after rehabilitation by applying lateral cyclic loading of increasing amplitudes. Two defects were considered for the two non‐seismic units, being the absence of transverse steel hoops and insufficient bond capacity of beam bottom steel reinforcing bars in the joint panel zone. The damaged specimens were rehabilitated by injecting epoxy grout into existing cracks and installing stiffened steel angles at the re‐entrant corners of the beam‐column joint, both above and below the beam, that were mounted and held in place using prestressed high‐tensile strength bars. The test results indicated that the seismic performance of the rehabilitated specimens in terms of strength, stiffness, and ductility was fully recovered and comparable with the performance of the seismically detailed specimen. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

8.
This paper presents a three‐dimensional analysis framework, based on the explicit finite element method, for the simulation of reinforced concrete components under cyclic static and dynamic loading. A recently developed triaxial constitutive model for concrete is combined with a material model for reinforcing steel which can account for rupture due to low‐cycle fatigue. The reinforcing bars are represented with geometrically nonlinear beam elements to account for buckling of the reinforcement. The strain penetration effect is also accounted for in the models. The modeling scheme is used in a commercial finite element program and validated with the results of experimental static and dynamic tests on reinforced concrete columns and walls. The analyses are supplemented with a parametric study to investigate the impact of several modeling assumptions on the obtained results.  相似文献   

9.
Earthquake‐resilient steel frames, such as self‐centering frames or frames with passive energy dissipation devices, have been extensively studied during the past decade, but little attention has been paid to their column bases. The paper presents a rocking damage‐free steel column base, which uses post‐tensioned high‐strength steel bars to control rocking behavior and friction devices to dissipate seismic energy. Contrary to conventional steel column bases, the rocking column base exhibits monotonic and cyclic moment–rotation behaviors that are easily described using simple analytical equations. Analytical equations are provided for different cases including structural limit states that involve yielding or loss of post‐tensioning in the post‐tensioned bars. A step‐by‐step design procedure is presented, which ensures damage‐free behavior, self‐centering capability, and adequate energy dissipation capacity for a predefined target rotation. A 3D nonlinear finite element (FE) model of the column base is developed in abaqus . The results of the FE simulations validate the accuracy of the moment–rotation analytical equations and demonstrate the efficiency of the design procedure. Moreover, a simplified model for the column base is developed in OpenSees . Comparisons among the OpenSees and abaqus models demonstrate the efficiency of the former and its adequacy to be used in nonlinear dynamic analysis. A prototype steel building is designed as a self‐centering moment‐resisting frame with conventional or rocking column bases. Nonlinear dynamic analyses show that the rocking column base fully protects the first story columns from yielding and eliminates the first story residual drift without any detrimental effect on peak interstory drifts. The study focuses on the 2D rocking motion and, thus, ignores 3D rocking effects such as biaxial bending deformations in the friction devices. The FE models, the analytical equations, and the design procedure will be updated and validated to cover 3D rocking motion effects after forthcoming experimental tests on the column base. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

10.
This study presents a cyclic load test of four RC columns to obtain data on stresses and strains on lateral shear‐reinforcing bars that contact buckled longitudinal reinforcing bars. The specimens include columns laterally jacketed with all‐elastic fibre‐reinforced polymer (FRP) sheets. The buckling lengths and modes in the longitudinal bars of the four column specimens stabilized at a buckling deflection (= lateral deformation of buckled longitudinal bar) from 0.3 to 0.6 mm. The yield portion ratio rby of shear reinforcement around the buckled longitudinal bars was introduced as an index of the development of buckling conditions. Here, the yield portion ratio rby was defined as the ratio of the length of the region where the shear reinforcements yield lby, to the buckling length lb. The rby values of the tested columns ranged from 0.45 to 0.76. The test results show that the buckling stress and the specific compressive stress of the longitudinal bars in the columns were smaller than those of the bare bars. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

11.
A numerical process that simulates crack propagation in reinforced concrete through post‐crack stress redistribution is presented. This process is developed within the context of the smeared crack approach. Continuity and orientation of the reinforcing bar components are automatically recognized in the pre‐processing stage. The process explicitly outputs crack widths by computing the bond slips along reinforcement, without imposing any additional nodes between the reinforcement and concrete. The process is incorporated with a finite element algorithm, and the validation is investigated through sample 3D static analyses of nine concrete specimens subjected to monotonic shear and flexure loads. These specimens contain relatively well‐distributed steel bars and fiber reinforced polymer (FRP) sheets of reinforcement ratio from 0.11 to 0.57%. The analyses predict the crack patterns and crack widths well, although some disagreements are found between the test and the analysis results. The proposed process outputs discrete, continuous in crack directions, and element boundary‐free crack patterns. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

12.
This paper investigated the use of external steel jacketing for seismic retrofit of non‐ductile reinforced concrete (RC) bridge columns to prevent lap‐splice failure. Three 1/2.5‐scale specimens were tested under cyclic loads. The effectiveness of two types of steel jackets for improving the ductility and strength of specimens using inadequate transverse reinforcing and lap‐splice details were examined. An octagonal steel jacketing scheme for the seismic retrofitting of rectangular RC bridge columns was proposed. In addition, the methods for seismic retrofitting rectangular columns using elliptical steel jacketing were also critically tested. The test results indicated that the octagonal steel jackets can effectively provide confinement thereby mitigating failures as a result of inadequate transverse reinforcing and inadequate lap‐splices. Tests also confirmed that the ductility performance and the energy dissipation capacity of the specimens can be significantly improved by the octagonal steel jacket. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
This study consists of two parts. In this two‐part research, four two‐story narrow steel plate shear walls (SPSWs) were cyclically tested at the Taiwan National Center for Research on Earthquake Engineering in 2007. This paper, Part 1, proposes a capacity design method for the first‐story boundary column of the SPSW to ensure that the plastic hinges form at the column bottom ends when the SPSW develops the plastic mechanism. The design method was developed based on the superposition method considering the frame sway action and the panel force effects of the SPSW. Restrained steel plate shear wall (R‐SPSW) studied herein adopts pairs of the horizontal restrainers sandwiching over both sides of the infill panels and connected to the boundary columns. Analytical studies on four SPSW example designs using nonlinear finite element (FE) models and the simplified strip models confirm that the restrainers could also effectively reduce the column force demands and allow the infill panel to stretch more uniformly. In addition, the FE analytical studies verify the effectiveness of the proposed column capacity design method and the seismic design recommendations for the restrainer. This paper introduces the designs of the four narrow SPSW specimens, presenting the selections of the boundary beams and columns, the designs of the beam‐to‐column connections and the construction details of the restrainers. The experimental results, key observations and the design implications are reported in the companion paper. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
Reinforced concrete columns with non‐ductile detailing typically exhibit a softening behavior characterized by severe degradation when subjected to cyclic lateral loads. Whether the response is brittle or ductile, shear failure occurs with an inclined through crack along which sliding occurs coupled with loss of horizontal and vertical load‐bearing capacity of the member. The rapid loss of resistance after the peak strength is reached is because of one or more of the following local failure mechanisms: brittle failure of poorly confined concrete; buckling of longitudinal reinforcing bars because of lack of adequate transverse reinforcement or following opening of stirrups after spalling of cover concrete; bond failure. In this study, a modeling strategy to build a detailed 3D finite element model capable of capturing all of the above‐mentioned local failure mechanisms is presented. In particular, a steel–concrete interface model for representing the interaction within the member between concrete core, cover and longitudinal and transverse reinforcement is proposed. Comparison with results of an experimental test of a shear‐sensitive column demonstrates the effectiveness of the simulation up to failure of the element. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

15.
The scope of this study is to present results of an experimental investigation on the behaviour of critical external beam–column joints repaired or/and strengthened with a combination of epoxy resin injections and carbon‐fibre‐reinforced plastics (C‐FRP) sheets and to extract useful and practical conclusions. The experimental program comprises 12 external beam–column joint connection subassemblages tested in cyclic loading. From the observed responses of the examined specimens it can be deduced that the technique of epoxy resin injections is appropriate for the total rehabilitation of the joints seismic capacity, since no damages have been observed at the joint area of the specimens after the repair. The combination of this technique with the use of C‐FRP sheets leads to a significant improvement of the loading capacity, the energy absorption and the ductility and finally it leads to improved type of damages compared with the damage modes of the specimens during the initial loading. Shortcomings of the application of C‐FRP sheets for practical use are also pointed out. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

16.
This paper deals with the assessment of the seismic response of a portal frame pier belonging to an old reinforced concrete viaduct. A series of tests, consisting of cyclically imposed displacements, were carried out on three 1:4 scale mock‐ups. The objective of the experimental campaign is twofold: (1) identification and evaluation of the local failure mechanisms and (2) calibration of a numerical model including all observed nonlinear phenomena. The experimental results show that the shear strength of the transverse beam and of the beam–column joints characterizes the post‐elastic behavior of the piers. Other phenomena, like bond‐slip and buckling of the longitudinal bars of the columns, typical of old reinforced concrete structures have also been observed. Finally, a numerical model, built in OpenSEES, was calibrated to reproduce in a satisfactory way the experimental results and to provide a reliable tool for the evaluation of the seismic response of the pier. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

17.
A series of shallowly embedded steel column bases consisting of an exposed column base and a floor slab is tested under horizontal cyclic loading to very large deformation. The effects of floor slabs on strength and ductility are examined using concrete and Steel fiber‐reinforced cementitous composites (SFRCC) for the floor slab. The elastic stiffness, maximum strength, and dissipated energy of the column bases when they include SFRCC increase by 40, 70, and 70% over those of corresponding column bases with concrete floor slab. Better bonding behavior is notable for SFRCC, and the maximum strength and dissipated energy further increase by 15–30% and 70–90%, respectively, owing to the careful arrangement of reinforcing bars. Numerical models are developed to enhance the understanding the behavior of shallowly embedded column bases. Procedures for estimating the elastic stiffness and maximum strength of shallowly embedded column bases with conventional concrete are calibrated for their applicability to those with SFRCC slab. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

18.
Glass fi ber reinforced gypsum(GFRG) wall panels are prefabricated panels with hollow cores, originally developed in Australia and subsequently adopted by India and China for use in buildings. This paper discusses identifi cation and calibration of a suitable hysteretic model for GFRG wall panels fi lled with reinforced concrete. As considerable pinching was observed in the experimental results, a suitable hysteretic model with pinched hysteretic rule is used to conduct a series of quasi-static as inelastic hysteretic response analyses of GFRG panels with two different widths. The calibration of the pinching model parameters was carried out to approximately match the simulated and experimental responses up to 80% of the peak load in the post peak region. Interestingly, the same values of various parameters(energy dissipation and pinching related parameters) were obtained for all fi ve test specimens.  相似文献   

19.
Past experimental studies have shown that existing precast segmental concrete bridge columns possess unsatisfactory hysteretic energy dissipation capacity, which is an undesirable feature for applications in seismic regions. In this research, we propose new methods of precast segment construction for tall concrete bridge columns to enhance the columns' hysteretic energy dissipation capacity and lateral strength. This is accomplished by adding bonded mild steel reinforcing bars across the segment joints, strengthening the joint at the base of the column and increasing the height of the base segment (hinge segment). Four large‐scale column specimens were fabricated and tested with lateral cyclic loading in the laboratory. Each specimen consisted of a foundation and 9 or 10 precast column segments. Test results of specimens with the proposed design concepts showed ductile behavior and satisfactory hysteretic energy dissipation capacity. In addition to the experimental study, an analytical study using the finite element method was conducted to understand the bond conditions, strain contours and deformation patterns of the specimens tested. Good agreement was found between the experimental observations and the results of the calibrated analytical study. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

20.
Self‐centering reinforced concrete frames are developed as an alternative of traditional seismic force‐resisting systems with better seismic performance and re‐centering capability. This paper presents an experimental and computational study on the seismic performance of self‐centering reinforced concrete frames. A 1/2‐scale model of a two‐story self‐centering reinforced concrete frame model was designed and tested on the shaking table in State Key Laboratory of Disaster Reduction in Civil Engineering at Tongji University to evaluate the seismic behavior of the structure. A structural analysis model, including detailed modeling of beam–column joints, column–base joints, and prestressed tendons, was constructed in the nonlinear dynamic modeling software OpenSEES. Agreements between test results and numerical solutions indicate that the designed reinforced concrete frame has satisfactory seismic performance and self‐centering capacity subjected to earthquakes; the self‐centering structures can undergo large rocking with minor residual displacement after the earthquake excitations; the proposed analysis procedure can be applied in simulating the seismic performance of self‐centering reinforced concrete frames. To achieve a more comprehensive evaluation on the performance of self‐centering structures, research on energy dissipation devices in the system is expected. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   