首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper presents a thorough study of the behavior of inclined micropiles under seismic loading. Analysis is carried out using a full three-dimensional finite element modeling. The soil media is assumed to be elastic with Rayleigh damping, while micropiles are modeled as 3D elastic beam elements. The structure is described by a single degree of freedom system composed of a concentrated mass and a column. The paper is composed of four parts. The first part includes a literature survey on the behavior of inclined micropiles. The second part presents the numerical model used in this study. The third part concerns analysis related to the influence of micropiles inclination on the seismic behavior of a group of micropiles embedded in a homogeneous soil with a uniform stiffness. The last part deals with the seismic behavior of inclined micropiles embedded in a soil layer with a depth-based increasing stiffness. The results of this study provide valuable information about the influence of micropiles inclination on dynamic amplification and on the seismic-induced internal forces in micropiles.  相似文献   

2.
The Hybrid A-Frame Micropile/MSE(mechanically stabilized earth) Wall suitable for mountain roadways is put forward in this study: a pair of vertical and inclined micropiles goes through the backfill region of a highway MSE Wall from the road surface and are then anchored into the foundation. The pile cap and grade beam are placed on the pile tops, and then a road barrier is connected to the grade beam by connecting pieces. The MSE wall's global stability, local stability and impact resistance of the road barrier can be enhanced simultaneously by this design. In order to validate the serviceability of the hybrid A-frame micropile/MSE wall and the reliability of the numerical method, scale model tests and a corresponding numerical simulation were conducted. Then, the seismic performance of the MSE walls before and after reinforcement with micropiles was studied comparatively through numerical methods. The results indicate that the hybrid A-frame micropile/MSE wall can effectively control earthquake-induced deformation, differential settlement at the road surface, bearing pressure on the bottom and acceleration by means of a rigid-soft combination of micropiles and MSE. The accumulated displacement under earthquakes with amplitude of 0.1-0.5g is reduced by 36.3%-46.5%, and the acceleration amplification factor on the top of the wall is reduced by 13.4%, 15.7% and 19.3% based on 0.1, 0.3 and 0.5g input earthquake loading, respectively.In addition, the earthquake-induced failure mode of the MSE wall in steep terrain is the sliding of the MSE region along the backslope, while the micropiles effectively control the sliding trend. The maximum earthquake-induced pile bending moment is in the interface between MSE and slope foundation, so it is necessary to strengthen the reinforcement of the pile body in the interface. Hence, it is proven that the hybrid A-frame micropile/MSE wall system has good seismic performance.  相似文献   

3.
This paper includes an analysis of the influence of soil plasticity on the seismic response of micropiles. Analysis is carried out using a global three-dimensional modeling in the time domain. The soil behavior is described using the non-associated Mohr–Coulomb criterion. Both the micropiles and the superstructure are modeled as three-dimensional beam elements. Proper boundary conditions are used to ensure waves transmission through the lateral boundaries of the soil mass. Analyses are first conducted for harmonic loadings and then for real earthquake records. They show that plasticity could have a significant influence on the seismic response of the soil–micropiles–structure systems. This influence depends on the amplitude of the seismic loading and the dominant frequencies of both the input motion and the soil–piles–structure system.  相似文献   

4.
A comprehensive dynamic three dimensional finite element model, which includes the effect of lots of important parameters on the micropiles seismic performance, has been presented. The validation of the built model has been carried out using remodeling a single degree of freedom shaking table test done by Mc Manus at the University of Canterbury. The gained results proved the accuracy of the constructed model. Then, using the parametric analysis, effects of all the earthquake characteristics, soil properties, superstructure and micropiles' cap and micropiles structure on the seismic performance of micropiles have been investigated by means of presenting internal forces and displacements which occurred as the main result of earthquake. Furthermore, using the data analysis, the most and the least influential parameters on internal forces are obtained based on the Cosine Amplitude Method (CAM).  相似文献   

5.
为研究微小含煤盆地倾斜煤层采空区的瞬变电磁法探测效果,以云南省新近系向斜盆地采空区为研究对象,从数值模拟与现场实测两方面对瞬变电磁探测效果展开研究。首先,针对研究区微小盆地构造条件建立倾斜煤层地电模型,以正演模拟和电阻率计算论证理论可行性;其次,根据模拟结果设置工作参数进行现场数据采集,以倾斜含煤段作为电性标志层追踪电阻率异常并推断采空区分布范围;最后,采用井下超前钻探对推断的采空区进行验证。结果表明,瞬变电磁法适用于探测微小盆地的构造变化而引起的地电结构的改变,探测结果清晰显示盆地倾斜含煤地层的起伏变化,能准确反映采空区的分布。   相似文献   

6.
为了研究装配式混凝土金属消能减震连接体系的抗震性能,对金属消能减震连接体系和普通预制装配式框架进行了数值仿真分析,分析了消能器不同设计参数对该体系抗震性能的影响。分析结果表明:金属消能减震连接体系的抗震性能优于普通预制装配式框架,屈服位移有显著提高,较好的延缓了梁端的破坏,对梁端保护作用明显,并且有效的解决了梁端后浇区施工困难的问题;金属消能器腹板高度越小耗能效果越好,但初始刚度及承载力也越小;翼缘板厚度越小消能器越早屈服耗能,但过小的翼缘板厚度会导致耗能能力不足,并且应变过大会导致其与梁柱连接部位被破坏;随着消能器高度的增加,构件跨中弯矩越大,也越早屈服耗能,但过大的消能器高度会导致其弯曲变形严重。  相似文献   

7.
A new method is proposed for the quantitative interpretation of SP field data produced by a polarized ore body and simulated by an inclined sheet. The theoretical concept is based on the study of the amplitude Spectrum. It is shown that the SP amplitude Spectrum is not continuous at zero frequency; this leads to the dip angle determination of the inclined sheet. It is also shown that the SP amplitude spectrum is practically nullified at a characteristic amortization frequency that depends on the depth of the polarized body. The maximum amplitude Spectrum value of the SP gradient is used to estimate the depth to the bottom of the polarized body. Thus, the geometrical parameters h and H, the depths to the top and bottom, respectively, as well as the dip angle of the inclined sheet, can be satisfactorily determined. Some problems may arise in the determination of these parameters, affecting their accuracy, whenever unwanted frequency noise is present.  相似文献   

8.
Seismic behavior of inclined piles has been considered detrimental for years. However, recent researches show that battered piles can have a beneficial effect. In this framework, a series of centrifuge tests on an inclined pile group is performed. The analysis is based on the comparative response of two 2×1 simplified pile groups: one with vertical piles and the other with one vertical and one inclined pile. The response of these pile groups to repeated earthquakes or sinusoidal inputs is analyzed through the response frequencies, the envelop curves of bending moment profiles, the axial loads measured in both piles and the kinematic response of the cap. Results highlight that the effect of inclined pile is highly influenced by the frequency content of the input. In addition, the inclined pile induces non-negligible residual bending moments, higher horizontal stiffness at the pile cap and larger rotation.  相似文献   

9.
带斜筋单排配筋混凝土剪力墙结构是为取代粘土砖多层住宅结构而发展起来的一种新型多层混凝土结构,其经济性合理,抗震性能优于传统的砌体结构.为进一步充分了解其抗震性能,开展该新型结构体系中“L”形截面剪力墙的非工程轴方向抗震性能试验研究.进行1个单排配筋混凝土“L”形截面剪力墙和1个带斜筋的单排配筋混凝土“L”形截面剪力墙低周反复荷载试验,对比分析其破坏特征、滞回特性、耗能能力、承载力、延性、刚度,并利用ABAQUS软件进行非线性有限元分析,探究斜筋对其抗震性能的影响.研究结果表明,在非工程轴方向,带斜筋单排配筋“L”形截面混凝土剪力墙的抗震性能优于不带斜筋的剪力墙.  相似文献   

10.
查小惠 《地震》2022,42(1):99-110
利用接收函数谐波分解方法可以提取地壳下方的不均匀信息,但当多种不均匀性同时存在时,该方法反演结果的准确性目前尚不十分清楚。基于5组20个理论模型,研究了倾斜界面和各向异性对谐波分解方法的影响。结果表明,对于只存在倾斜界面的情况,利用谐波分解方法可以很好地得到模型参数。在各向异性和倾斜界面同时存在的情况下,各向异性的存在会影响谐波分解得到的倾斜界面振幅信息,而且这种影响还和倾斜界面的走向有关。倾斜轴各向异性谐波分解得到的各向异性强度与倾斜轴倾角大小有关,与快轴方向关系不大。使用谐波分解方法对江西九江台进行分析,结果表明,台站下方倾斜和各向异性共存,快轴方向约为86°,时间延迟约为0.46 s。  相似文献   

11.
本文提出了高层建筑多塔楼连廊结构采用柔性连接方式,并进行了结构抗震分析和模拟地震振动台试验研究。计算和试验结果表明连廊采取柔性连接后,结构在连廊连接处的受力状况得到改善,结构的基底剪力明显减小,柔性连接有一定的耗能能力,提高了建筑物的抗震性能。  相似文献   

12.
结合克拉玛依市科技博物馆工程,对超限倾斜结构设定性能设计目标,并针对性能目标提出抗震措施及抗震构造措施.考虑结构材料的非线性属性,采用静力非线性分析方法,分析倾斜框架-剪力墙结构在地震作用下的响应,尤其是结构在罕遇地震作用下的非线性动力特性.结果表明,结构在罕遇地震下也是安全可靠的,剪力墙尚处在弹性范围,未出现塑性铰,...  相似文献   

13.
The subsurface spatial variation in clay soils, such as thin-layered sand seams, affects the mechanical strength and electrical resistivity. The objective of this study is the development and application of cone resistivity penetrometer (CRP), which measures the cone tip resistance, sleeve friction, and electrical resistivity to evaluate the subsurface spatial variability. The electrical resistivity is measured at the cone tip to increase its resolution. Two outer diameters of the cone resistivity penetrometers (CRPs) are developed: D=10 mm CRP with a projected area of 0.78 cm2 and D=15 mm CRP with a projected area of 1.76 cm2. The cone tip resistance is effectively separated using a friction sleeve. Strain gauges are used to measure the mechanical strength, and coaxial type electrodes monitor the electrical resistivity. The application tests in the laboratory are conducted using layered soils and saturated sands. In addition, the penetration tests in the field are carried out and compared with the standard piezocone test. The penetration tests show that the soil layers and the density changes are clearly detected by the electrical resistivity and mechanical strength. Field tests show that CRP clearly evaluates the subsurface profile. This study suggests that CRP may be a useful technique for the evaluation of subsurface spatial variability during penetration testing.  相似文献   

14.
郭涛  宋娟  姚激  魏业清 《地震工程学报》2009,31(3):254-258,264
依据现行抗震设计规范,运用三维有限元软件ANSYS对某25层大底盘非对称双塔连体结构进行了时程法地震反应分析,得到结构的自振特性和地震响应,并与未设连体的双塔结构的结果进行了比较.结果表明增设连体后双塔的扭转振型更加丰富,且运动和变形得到了统一和协调.  相似文献   

15.
Horizontal impedance functions of inclined single piles are measured experimentally for model soil-pile systems with both the effects of local soil nonlinearity and resonant characteristics.Two practical pile inclinations of 5° and 10° in addition to a vertical pile embedded in cohesionless soil and subjected to lateral harmonic pile head loadings for a wide range of frequencies are considered.Results obtained with low-to-high amplitude of lateral loadings on model soil-pile systems encased in a laminar shear box show that the local nonlinearities have a profound impact on the horizontal impedance functions of piles.Horizontal impedance functions of inclined piles are found to be smaller than the vertical pile and the values decrease as the angle of pile inclination increases.Distinct values of horizontal impedance functions are obtained for the ’positive’ and ’negative’ cycles of harmonic loadings,leading to asymmetric force-displacement relationships for the inclined piles.Validation of these experimental results is carried out through three-dimensional nonlinear finite element analyses,and the results from the numerical models are in good agreement with the experimental data.Sensitivity analyses conducted on the numerical models suggest that the consideration of local nonlinearity at the vicinity of the soil-pile interface influence the response of the soil-pile systems.  相似文献   

16.
根据Buckingham π定理设计制作直群桩和斜群桩相似模型,通过电磁式振动台试验方法,分别考虑非液化砂土、300 mm和380 mm两种不同厚度饱和砂土,开展在规则正弦波输入下桩土相互作用P-Y滞回曲线规律研究.结果 表明:在非液化砂土中,P-Y滞回曲线的主斜率变化较小,说明在振动输入过程中,桩周土体刚度并未发生显...  相似文献   

17.
Small-diameter microcones have been widely used for the characterisation of soil properties in the field and in the calibration chamber because the smaller probe may require a smaller penetrometer capacity and a smaller calibration chamber. As the cone size decreases, the area required for the installation of the strain gauges also decreases, and thus, the half-bridge circuit has been generally adopted. The objective of this study is the development and application of a microcone configured with a full-bridge circuit instead of the half-bridge circuit for the measurement of the cone tip resistance and sleeve friction. The diameter of the microcone is designed to be D=15 mm, and thus, the projected area is 1.76 cm2. The full-bridge circuit in the microcone is configured by extending the rod behind the connection part for the installation of four strain gauges. Two strain gauges are installed in the loading part, and two strain gauges are installed in the extended rod. In addition, the half-bridge circuit is also used for comparison of the cone tip resistance and sleeve friction in both circuits. The advantages of the microcone with the extended rod are verified through a theoretical background study and through experimental studies of various parameters, including temperature calibration, stress calibration, and densification monitoring. The test results show that the extended rod-type microcone with a full-bridge is less affected by environmental effects and produces better linearity between the output voltage and the stress. In addition, the full-bridge circuit yields more reasonable and reliable cone tip resistance and sleeve friction values than the half-bridge circuit. This study demonstrates that the extended rod-type microcone may be an alternative choice for the configuration of the full-bridge for better resistance measurements.  相似文献   

18.
The isolation of vibrations from the surroundings is one of the important problems in the design of machine foundations. The use of open trenches, infilled trenches, single and multiple pile rows have been widely studied. In this paper, the vibration screening efficiency of an inclined secant micro-pile wall positioned as an active vibration barrier is investigated. The study is performed using three-dimensional time domain finite element analyses. Various parameters such as barrier depth, inclination, barrier distance and load excitation frequency were studied. The results show that inclined secant micro-pile walls are a viable vibration isolation option for a multitude of vibration problems. It is shown that varying barrier inclination angle from 90° to 120° improved vibration isolation performance as high as 44% relative to the vertical barrier for the active isolation case. The effectiveness of the barrier increases as its depth increases and also as the excitation frequency increases. The orientation of the inclined barrier towards or against vibration source is shown to be a fundamental design consideration.  相似文献   

19.
以青海共和至玉树高等级公路中的实际设计断面为模型,通过数值模拟研究斜插式热棒路基和斜插式热棒-XPS复合路基的降温效果。结果表明,在气候变暖背景下,两种路基在一定时期内可以降低其下部多年冻土温度,提高路基下冻土上限,但随着气温逐渐升高,两种路基反压护道下多年冻土中有融化核出现,并且斜插式热棒路基下多年冻土中及斜插式热棒-XPS复合路基填土中有融化核出现;增加XPS保温板,在一定时期内可以提升斜插式热棒路基的降温能力,使斜插式热棒-XPS复合路基降温效果优于斜插式热棒路基,且前者冻土上限始终高于后者,但对于增强其长期降温的效果并不显著。  相似文献   

20.
周晓洁    程昌恽    杜金鹏    陈康    陈培奇   《世界地震工程》2022,38(2):046-57
为进一步改善框架结构平面内和平面外抗震性能,本文提出带X形斜撑的新型砌体填充墙构造方案,并进行了4榀蒸压加气混凝土砌块砌体填充墙框架结构试验,以研究墙体构造措施和墙-框连接方式对框架结构抗震性能的影响。首先进行平面内水平低周往复荷载试验,随后进行历经平面内损伤的平面外单调静力加载试验,最后进行承载力、刚度退化和耗能能力等抗震性能指标的分析。结果表明:墙-框柔性连接方案下,填充墙框架结构的平面内及平面外水平承载力和初始刚度均小于刚性连接方案,而变形能力、耗能能力和位移延性等性能指标均比刚性连接表现更好;墙-框柔性连接且填充墙带X形斜撑框架结构的平面内及平面外抗震性能指标均有明显改善,更有利于抗震。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号