黄忠洲 《海洋技术学报》2006,25(2):55-58,106
文中利用实验方法系统研究了负载控制技术对OW C波能转换装置的影响。研究结果表明,当透平完成自起动过程后,在装置输出最佳工况点处,输入波况对平均最佳进气迎角的影响很小,其值基本处于8~10°之间。因此,为实现变工况下波能装置的最佳性能输出,只需保证透平的平均进气迎角始终处于上述范围。反之,利用文中给出的平均最佳进气迎角也可确定透平的最佳转速,进而确定最佳工况点。  相似文献   

2.
Oscillating Water Column (OWC) is one of the pioneer devices in harnessing wave energy; however, it is not fully commercialized perhaps due to the complicated hydrodynamic behavior. Previous studies are significantly devoted to OWC devices located in nearshore and coastal regions where incident wave energy would experience dissipation more than offshore. In this paper, a 1:15 scaled fixed offshore OWC model is tested in a large towing tank of National Iranian Marine Laboratory. Wave spectrum shape effect on the efficiency of the OWC model is addressed. Moreover, the paper investigates the effects of the geometric and hydrodynamic factors on OWC device efficiency and uncovers new points in nonlinear interaction occurring inside the chamber; i.e. sloshing. The results indicate that shape of the spectrum inside the chamber is affected by the type of incident wave spectrum, especially for long waves. Pierson–Moskowitz spectrum leaded to higher efficiency rather than JONSWAP spectrum at longer incident wave periods. According to efficiency analysis, increasing wave height may lead to air leakage from the chamber followed by vortex generation, which is a reason for decreasing the efficiency of the OWC device. Furthermore, no shift in the resonant period of the OWC model, due to wave height increase, was observed at the opening ratios equal or smaller than 1.28%. Spectral analysis of water fluctuation inside the OWC chamber illustrates two modes of sloshing. The first mode can be seen at short period waves while the second mode is visible at long period waves. The sloshing modes approximately vanish by increasing draft value.  相似文献   

3.
基于VOF模型的OWC气室波浪场数值分析   总被引:1,自引:0,他引:1  
近年来,振荡水柱形式在波能转换装置中得到了广泛应用,由于波况不同,需对气室加以研究并对其形状参量进行优化,从而使空气流速和能量转换达到最大值.利用基于VOF模型建立二维数值波浪水槽,将数值计算的振荡水柱在气室内的升沉运动与物理模型试验进行比较,验证其正确性,并将OWC气室的研究手段予以推广.  相似文献   

4.
刘臻 《中国海洋工程》2011,25(1):169-178
Oscillating Water Column (OWC) wave energy converting system is one of the most widely used facilities all over the world.The air chamber is utilized to convert the wave energy into the pneumatic energy.The numerical wave tank based on the two-phase VOF model is established in the present study to investigate the operating performance of OWC air chamber.The RANS equations,standard k-ε turbulence model and dynamic mesh technology are employed in the numerical model.The effects of incident wave conditions and shape parameters on the wave energy converting efficiency are studied and the capability of the present numerical wave tank on the corresponding engineering application is validated.  相似文献   

5.
The performance of an oscillating water column (OWC) wave energy converter depends on many factors, such as the wave conditions, the tidal level and the coupling between the chamber and the air turbine. So far most studies have focused on either the chamber or the turbine, and in some cases the influence of the tidal level has not been dealt with properly. In this work a novel approach is presented that takes into account all these factors. Its objective is to develop a virtual laboratory which enables to determine the pneumatic efficiency of a given OWC working under specific conditions of incident waves (wave height and period), tidal level and turbine damping. The pneumatic efficiency, or efficiency of the OWC chamber, is quantified by means of the capture factor, i.e. the ratio between the absorbed pneumatic power and the available wave energy. The approach is based on artificial intelligence—in particular, artificial neural networks (ANNs). The neural network architecture is chosen through a comparative study involving 18 options. The ANN model is trained and, eventually, validated based on an extensive campaign of physical model tests carried out under different wave conditions, tidal levels and values of the damping coefficient, representing turbines of different specifications. The results show excellent agreement between the ANN model and the experimental campaign. In conclusion, the new model constitutes a virtual laboratory that enables to determine the capture factor of an OWC under given wave conditions, tidal levels and values of turbine damping, at a lower cost and in less time than would be required for conventional laboratory tests.  相似文献   

6.
Investigation on the Oscillating Buoy Wave Power Device   总被引:4,自引:0,他引:4  
SU  Yongling 《中国海洋工程》2002,16(1):141-149
An oscillating buoy wave power device (OD) is a device extracting wave power by an oscillating buoy. Being excited by waves, the buoy heaves up and down to convert wave energy into electricity by means of a mechanical or hydraulic device. Compared with an Oscillating Water Column (OWC) wave power device, the OD has the same capture vvidth ratio as the OWC does, but much higher secondary conversion efficiency. Moreover, the chamber of the OWC, which is the most expensive and difficult part to be built, is not necessary for the OD, so it is easier to construct an OD. In this paper, a nu-merical calculation is conducted for an optimal design of the OD firstly, then a model of the device is built and, a model test is carried out in a wave tank. The results show that the total efficiency of the OD is much higher than that of the OWC and that the OD is a promising wave power device.  相似文献   

7.
Li  Meng  Wu  Ru-kang  Wu  Bi-jun  Zhang  Yun-qiu 《中国海洋工程》2019,33(3):297-308

Wave tank tests were carried out to evaluate the total efficiency of a floating OWC Pentagonal Backward Bent Duct Buoy (PBBDB). Two kinds of turbine generators were used in tests. The incident wave power, pneumatic power and electricity were measured. The test results show that the primary efficiency can reach up to 185.98% in regular waves and 85.86% in irregular waves. The total efficiency from wave to wire with Wells turbine-generator set is 33.43% in regular waves and 15.82% in irregular waves. The peak total efficiency of the PBBDB with check valves equipped with the impulse turbine-generator set is 41.68% in regular waves and 27.10% in irregular waves. The efficiency of the turbine-generator set is about 30% in the tests. Obviously, the total efficiency can be further improved with the increasing of turbine efficiency.

  相似文献   

8.
《Ocean Engineering》2004,31(11-12):1407-1421
The paper presents an optimization study for the mechanical and electrical equipment of an oscillating-water-column (OWC) wave power plant of fixed shoreline or nearshore type, equipped with an air turbine. The plant’s structure geometry is assumed to be given and the corresponding hydrodynamic coefficients are known as functions of wave frequency. A stochastic model is adopted for the energy conversion process from wave to air turbine, it being assumed that the system is linear. The optimization concerns the turbine size, represented by its rotor diameter D. Two alternative criteria are used: (i) maximization of the produced electrical energy, (ii) maximization of the annual profit. An example calculation is presented, based on the hydrodynamic coefficients of the OWC on the island of Pico, Azores, and on the aerodynamic performance curves of its Wells turbine. The influence of the following parameters upon optimized turbine size and rated power output is analyzed: wave climate, capital costs of mechanical and electrical equipment, operation and maintenance costs, discount rate, equipment lifetime and price of electrical energy supplied to the grid.  相似文献   

9.
空气透平的压降作用及由其带来的空气流速变化,是串联2次能量转换过程、实现两转换过程耦合的核心要素.试验主要是在物理模型的基础上,对带有冲击式透平的OWC装置能量转换影响因素进行研究.试验主要考察2次能量转换耦合作用下,气室内自由水面变换、气室内压强变化、输气管内空气流速变换及三者耦合与相互作用.  相似文献   

10.
The motion and the drift force of a floating OWC (oscillating water column) wave energy device in regular waves are studied taking account of the oscillating surface-pressure due to the pressure drop across the duct of the air chamber. The potential problem inside the chamber is formulated by making use of the Green integral equation associated with the Rankine-type Green function while the outer problem with the Kelvin-type Green function. The added mass, wave damping and excitation coefficients as well as the motion and drift force of the OWC device are calculated for various values of parameter related to the pressure drop.  相似文献   

11.
振荡水柱装置是目前世界上应用最为广泛的岸式波能发电装置.气室作为该装置的主要结构可将入射波浪的能量转换为往复振荡的气流动能,是完成能量一次转换的关键结构.为了建立用于考察入射波浪、气室内的波面振荡变化,准确预测气室工作性能的三维数值模拟模型,构建了基于VOF模型的三维数值波浪水槽.通过与物理模型试验的结果对比发现,该模...  相似文献   

12.
This paper investigates by numerical simulation the influence of the Wells turbine aerodynamic design on the overall plant performance, as affected by the turbine peak efficiency and the range of flow rates within which the turbine can operate efficiently. The problem of matching the turbine to an oscillating water column (OWC) is illustrated by taking the wave climate and the OWC of the Azores power converter. The study was performed using a time-domain mathematical model based on linear water wave theory and on model experiments in a wave tank. Results are presented of numerical simulations considering several aerodynamic designs of the Wells turbine, with and without guide vanes, and with the use of a bypass pressure-relief valve.  相似文献   

13.
A three-dimensional (3D) numerical model of fixed Oscillating Water Column system (OWC) is presented and validated. The steady-state potential flow boundary value problem due to regular wave interaction with the OWC is solved by a first order mixed distribution panel method. Ocean response predictions are derived using a deterministic statistical model based on a spectral analysis method. The model validation focusses on diffraction predictions and involves convergence tests and numerical comparisons with independent potential flow computations. Predictions of both regular and irregular wave responses are also compared against experimental results. Sample results including the yearly-averaged power conversion efficiency are presented in the final section to illustrate the method’s suitability to a 3D hydrodynamic design optimisation.  相似文献   

14.
Wave Energy Converters (WECs) have excellent potential as a source of renewable energy that is yet to be commercially realised. Recent attention has focused on the installation of Oscillating Water Column (OWC) devices as a part of harbor walls to provide advantages of cost–sharing structures and proximity of power generation facilities to existing infrastructure. In this paper, an incompressible three–dimensional CFD model is constructed to simulate a fixed Multi–Chamber OWC (MC–OWC) device. The CFD model is validated; the simulation results are found to be in good agreement with experimental results obtained from a scale physical model tested in a wave tank. The validated CFD model is then used for a benchmark study of 96 numerical tests. These investigate the effects of the PTO damping caused by the power take–off (PTO) system on device performance. The performance is assessed for a range of regular wave heights and periods. The results demonstrate that a PTO system with an intermediate damping can be used for all chambers in the MC–OWC device for most wave period ranges, except for the long wave periods. These require a higher PTO damping. An increased incident wave height reduces the device capture width ratio, but there is a noticeable improvement for long wave periods.  相似文献   

15.
本文对振荡水柱波能装置的水柱做了时域计算,研究了内水柱在气室处于封闭状态、有阻尼状态和无阻尼状态下的动力响应。得出了相应的波浪载荷,并对波能装置的几种保护措施作了探讨。数值结果表明,带有阻尼的气室不能有效地阻止内水柱的运动,将使结构承受危险载荷的打击;全封闭的气室能有效地阻止内水柱的运动,但可能使气室里产生高压;收缩口与破浪锥联合作用,可以消耗水柱的动能,大大地减少载荷,是一种有前途的保护措施。  相似文献   

16.
刘臻  赵环宇  崔莹 《海洋工程》2015,29(5):663-672
Impulse turbine, working as a typical self-rectifying turbine, is recently utilized for the oscillating water column (OWC) wave energy converters, which can rotate in the same direction under the bi-directional air flows. A numerical model established in Fluent is validated by the corresponding experimental results. The flow fields, pressure distribution and dimensionless evaluating coefficients can be calculated and analyzed. Effects of the rotor solidity varying with the change of blade number are investigated and the suitable solidity value is recommended for different flow coefficients.  相似文献   

17.
Understanding the hydrodynamic interactions between ocean waves and the oscillating water column (OWC) wave energy converter is crucial for improving the device performance. Most previous relevant studies have focused on testing onshore and offshore OWCs using 2D models and wave flumes. Conversely, this paper provides experimental results for a 3D offshore stationary OWC device subjected to regular waves of different heights and periods under a constant power take–off (PTO) damping simulated by an orifice plate of fixed diameter. In addition, a 3D computational fluid dynamics (CFD) model based on the RANS equations and volume of fluid (VOF) surface capturing scheme was developed and validated against the experimental data. Following the validation stage, an extensive campaign of computational tests was performed to (1) discover the impact of testing such an offshore OWC in a 2D domain or a wave flume on device efficiency and (2) investigate the correlation between the incoming wave height and the OWC front wall draught for a maximum efficiency via testing several front lip draughts for two different rear lip draughts under two wave heights and a constant PTO damping. It is found that the 2D and wave flume modelling of an offshore OWC significantly overestimate the overall power extraction efficiency, especially for wave frequencies higher than the chamber resonant frequency. Furthermore, a front lip submergence equal to the wave amplitude affords maximum efficiency whilst preventing air leakage, hence it is recommended that the front lip draught is minimized.  相似文献   

18.
In order to study the effects of coastline on wave power absorption, we describe here a linearized theory of an oscillating water column (OWC) installed on a straight coast. The sea depth is assumed to be constant and the coast is a vertical cliff. The column is a vertical circular cylinder half embedded in the cliff and open on the seaside. Forced by incident waves from any direction, the water surface inside pushes the dry air above through a Wells turbine system to generate power. Carrying out the linearized theories of radiation and diffraction analytically, we calculate the coefficients of apparent mass and radiation damping, and the chamber pressure. Optimum absorption efficiency is examined under the constraint of constant chamber volume. Results are compared with a parallel study of an OWC installed either offshore or at the tip of a thin breakwater.  相似文献   

19.
The hydrodynamic functioning of an oscillating water column (OWC) in the presence of an underwater tri-dimensional mound (UTDM) through large-scale ocean engineering basin experiments is described. Experiments are carried out with both regular and irregular waves and are compared to numerical models. The analysis is based on the measurements of the wave amplification in the water column for the OWC performance and on surface deformation upwave and over the UTDM for the wave transformation due to both UTDM and OWC. A significant increase of the capture-width ratio due to wave focusing above the mound is observed experimentally. This wave focusing is also well described numerically with a refraction–diffraction model. The wave amplification in the water column for both regular and irregular waves is compared to results from a linear potential model based on an integral matching method. Linear behaviour of the hydrodynamic response of the device is verified for both open and partially closed conditions, in particular for irregular waves.  相似文献   

20.
In recent times, self-rectifying axial-flow air turbines are being widely employed in oscillating water column (OWC) wave energy converters (WEC). The steady performance of air turbines has been systematically investigated in previous studies. However, there still exists a lack of information on their unsteady performance, such as in the self-starting characteristics and subsequent running behavior. In this study, the unsteady behavior of impulse turbine under various constant-flow conditions is investigated. Experimental studies were conducted to investigate the effects of constant-load on the variations in the rotation speed, the pressure drop and the torque output of the turbine starting from rest. A fully passive flow-driving numerical model is employed for further detailed analysis of the flow and pressure fields. Followed by a well-agreed validation using the corresponding experimental data, the three dimensional (3D) transient model is used to study the effects of the air-flow velocity magnitude and the rotors’ moment of inertia on the self-starting performance of the turbine. Except for the variations in the rotation speed, the pressure drop and the pneumatic torque, the distributions of the flow-field and the pressure over the blades at specific time-points are analyzed.  相似文献   