首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 515 毫秒
1.
The influence of the mixtures HF‐HNO3 and HF‐NH4F‐HNO3 in bomb digestion for trace element determination from different rock types was studied using ICP‐MS. It is shown that the HF concentration, not the ratio of reagents in the decomposing mixture, controls the digestion process of a rock. Data for Zr in the granite G‐2 as a function of HF concentration gave the same results as reaction mixtures of various compositions. A complete digestion in 50‐mg sample bombs was achieved by 1.0 ml of HF alone, or with a mixture of other acids at a HF concentration of at least 35% m/m at 196 °C over 18 h. The results of the analysis of basalts BCR‐1, BIR‐1, mica schist SDC‐1, shale SBC‐1, granites G‐2, SG‐1A, garnet‐biotite plagiogneiss GBPg‐1, rhyolite RGM‐1, granodiorite GSP‐1, trachyandesite MTA‐1 and rhyolite MRh‐1 are given and compared against available data. The reproducibility of the element determinations by ICP‐MS and XRF as an independent non‐destructive analysis for a quality check in the range of concentrations typical for routine rock samples is given.  相似文献   

2.
Sample digestion is a critical stage in the process of chemical analysis of geological materials by ICP‐MS. We present a new HF/HNO3 procedure to dissolve silicate rock samples using a high pressure asher system. The formation of insoluble AlF3 was the major obstacle in achieving full recoveries. This was overcome by setting an appropriate digestion temperature and adding Mg to the samples before digestion. Sodium peroxide sintering was also investigated and the inclusion of a heating step to the alkaline sinter solution improved the recoveries of thirteen elements other than the lanthanides. The results of these procedures were compared with data sets generated by common acid decomposition techniques. Forty‐one trace elements were determined using an ICP‐QMS equipped with a collision cell. Under optimum conditions of gas flow and kinetic energy discrimination, polyatomic interferences were eliminated or attenuated. The measurement bias obtained for eight reference materials (BCR‐2, BHVO‐2, BIR‐1, BRP‐1, OU‐6, GSP‐2, GSR‐1 and RGM‐1) and intermediate precision (RSD) were generally better than ± 5%. The expanded measurement uncertainties estimated for two certified reference materials were mostly between 7 and 15%. New data sets for the reference materials are provided, including constituents with previously unavailable values and also for the USGS candidate reference material G‐3.  相似文献   

3.
Mass fractions of S, Cu, Se, Mo, Ag, Cd, In, Te, Ba, Sm, W and Tl were determined by isotope dilution sector field ICP‐MS in the same sample aliquot of reference materials using HF‐HNO3 digestion in PFA beakers in pressure bombs and glassy carbon vessels in a high‐pressure asher (HPA‐S) for comparison. Additionally, Bi was determined by internal standardisation relative to Tl. Because isobaric and oxide interferences pose problems for many of these elements, efficient chromatographic separation methods in combination with an Aridus desolvator were employed to minimise interference effects. Repeated digestion and measurement of geological reference materials (BHVO‐1, BHVO‐2, SCo‐1, MAG‐1, MRG‐1 and UB‐N) gave results with < 5% relative intermediate precision (1s) for most elements, except Bi. Replicates of NIST SRM 612 glass digested on a hot plate were analysed by the same methods, and the results agree with reference values mostly within 2% relative deviation. Data for the carbonaceous chondrites Allende, Murchison, Orgueil and Ivuna are also reported. Digestion in a HPA‐S was as efficient as in pressure bombs, but some elements displayed higher blank levels following HPA‐S treatment. Pressure bomb digestion yielded precise data for volatile S, Se and Te, but may result in high blanks for W.  相似文献   

4.
Complete dissolution is essential to obtain accurate analytical results for geological samples. Felsic rocks are known to be very difficult to dissolve because of the presence of refractory minerals such as zircon. In this study, we undertook a systematic evaluation of the effect of the HF/HNO3 ratio, digestion time, digestion temperature, digested test portion mass and the presence of insoluble fluorides on analytical results for the felsic rock GSP‐2 using high‐pressure HF and HF/HNO3 digestion. Digestion in mixtures of HF and HNO3 acids is a commonly used method of dissolution for geological samples. However, our results clearly indicate that adding HNO3 inhibited the digestion capabilities of HF for refractory minerals such as zircon. It took 8–12 hr for Zr to be completely recovered in GSP‐2 at 190 °C, whereas it needed about 36 and 72 hr at 160 and 140 °C, respectively. White precipitates were observed in the final solution for test portion mass > 100 mg, irrespective of which of the five different digestion solutions was used (1 ml HF, 2 ml HF, 1 ml HF + 0.5 ml HNO3, 1 ml HF + 1 ml HNO3 and 1.5 ml HF + 1.5 ml HNO3). Environmental scanning electron microscopy showed that these precipitates were mainly composed of AlF3. Instead of further HCl, HNO3 or HClO4 attack, we propose that using ultra‐fine samples and a small sample size is a good way to avoid the formation of insoluble residues (e.g., fluorides). To further investigate the precision and accuracy of the proposed method (using HF alone as the digestion solution during the first acid attack step), a suite of silicate rock reference materials was analysed. Most of the results were found to be in reasonable agreement with the reference values, with a relative error of < 10%.  相似文献   

5.
Trace elements from samples of bauxite deposits can provide useful information relevant to the exploration of the ore‐forming process. Sample digestion is a fundamental and critical stage in the process of geochemical analysis, which enables the acquisition of accurate trace element data by ICP‐MS. However, the conventional bomb digestion method with HF/HNO3 results in a significant loss of rare earth elements (REEs) due to the formation of insoluble AlF3 precipitates during the digestion of bauxite samples. In this study, the digestion capability of the following methods was investigated: (a) ‘Mg‐addition’ bomb digestion, (b) NH4HF2 open vessel digestion and (c) NH4F open vessel digestion. ‘Mg‐addition’ bomb digestion can effectively suppress the formation of AlF3 and simultaneously ensure the complete decomposition of resistant minerals in bauxite samples. The addition of MgO to the bauxite samples resulted in (Mg + Ca)/Al ratios ≥ 1. However, adding a large amount of MgO leads to significant blank contamination for some transition elements (V, Cr, Ni and Zn). The NH4HF2 or NH4F open vessel digestion methods can also completely digest resistant minerals in bauxite samples in a short period of time (5 hr). Unlike conventional bomb digestion with HF/HNO3, the white precipitates and the semi‐transparent gels present in the NH4HF2 and NH4F digestion methods could be efficiently dissolved by evaporation with HClO4. Based on these three optimised digestion methods, thirty‐seven trace elements including REEs in ten bauxite reference materials (RMs) were determined by ICP‐MS. The data obtained showed excellent inter‐method reproducibility (agreement within 5% for REEs). The relative standard deviation (% RSD) for most elements was < 6%. The concentrations of trace elements in the ten bauxite RMs showed agreement with the limited certified (Li, V, Cr, Cu, Zn, Ga, Sr, Zr and Pb) and information values (Co, Ba, Ce and Hf) available. New trace element data for the ten RMs are provided, some of which for the first time.  相似文献   

6.
We present a revised alkali fusion method for the determination of trace elements in geological samples. Our procedure is based on simple acid digestion of powdered low‐dilution (flux : sample ≈ 2 : 1) glass beads where large sample dilution demanded by high total dissolved solids, a main drawback of conventional alkali fusion, could be circumvented. Three geological reference materials (G‐3 granite, GSP‐2 granodiorite and SGD‐1a gabbro) decomposed by this technique and routine tabletop acid digestion were analysed for thirty trace elements using a quadrupole ICP‐MS. Results by conventional acid digestion distinctly showed poor recoveries of Zr, Hf and rare earth elements due to incomplete dissolution of resistant minerals. On the other hand, results obtained by our method were in reasonable agreement with reference data for most analytes, indicating that refractory minerals were efficiently dissolved and volatile loss was insignificant.  相似文献   

7.
The complete dissolution of representative test portions of powdered rock samples for the determination of the mass fractions of trace elements by ICP‐MS relies either on aggressive and time‐consuming acid digestions or fusion/sintering with appropriate fluxes. Here, we evaluate a microwave oven dissolution method that employs a solution of NH4HF2 and HNO3. The entire procedure occurs in a closed vessel system and takes up to 4 h. In hundreds of digestions, the precipitation of fluorides was never observed. Replicate decomposition of 100 mg of twenty‐one international reference materials (RMs) of igneous rocks, and also one of a shale presented mostly satisfactory recoveries of forty‐one trace elements. Important exceptions were Zr and Hf in G‐2 and GSP‐2 (mean recoveries of ca. 70%), although for four other felsic rock RMs, the digestion was complete. For ultramafic rock RMs, we present Cr results that indicate quantitative dissolution of Cr‐bearing phases. We discuss the findings and conclude that advances in sample preparation of geological materials for instrumental analysis would benefit from a better understanding of how specific characteristics, such as composition and crystallinity of certain minerals, may affect their reactivity.  相似文献   

8.
Bromine and iodine are important tracers for geochemical and environmental studies. In this study, a rapid acid digestion (HNO3 + HF) with ammonia dilution for the simultaneous determination of bromine and iodine in soils and sediments using ICP‐MS was developed. The recoveries of Br and I were controlled by the synergic effect of temperature and time. It took only 15 min at 140 °C for the complete recovery of Br and I in sediment (GSD‐2) and soil (GSS‐24) reference materials, which is a process that needs 2–6 h at 90 °C. A serious loss of Br and I was found at a higher digestion temperature of 190 °C. A 5% v/v NH4OH dilution effectively eliminated the memory effects and stabilised the signals of Br and I. Moreover, ammonia dilution also avoided the corrosiveness of HF on the sample introduction system and torch of ICP‐MS. Tellurium is a more suitable internal standard element than In in the ammonia medium. To avoid the adsorption of residues of dissolution on Te, addition of Te should be carried out after centrifuging the solution. The developed method was successfully applied to determine Br and I in fifty‐three Chinese soil and sediment reference materials. This simple method shows great potential for the rapid determination of Br and I in large batches of geological and environmental samples commonly analysed for mineral exploration and environmental geochemistry studies.  相似文献   

9.
Desilicification elevates extraction of Re and platinum‐group elements (PGEs) from many geological reference materials (RMs), but the extent to which it affects less chalcophile elements has been investigated rarely. To further evaluate the effect of desilicification, mass fractions of elements with variable chalcophile affinities (In, Cd, Cu, Ag, S, Se, Te, Re and PGEs) in different RMs were obtained by isotope dilution and digestion procedures involving HF‐HNO3 in bombs versus HNO3‐HCl in Carius tubes. The results show that the extraction efficiencies of HF‐desilicification vary in different RMs and for different elements. HF‐desilicification led to a significant increase (30–70%) for In and Cd mass fractions in all analysed RMs, but it played a negligible role in other strongly chalcophile elements in many samples (e.g., UB‐N and WGB‐1). Noticeably, desilicification led to a 10–30% increase in the mass fractions of Cu, Ag, S, Se and Te in BHVO‐2 and BIR‐1a, but less so in BCR‐2. These results could be attributed mainly to the variable chalcophile affinities of elements and their relative budget in sulfides, alloys and silicates. Desilicification should thus be preferred to determine chalcophile elements for most samples, except in cases where they are negligibly hosted in silicates.  相似文献   

10.
A simple flux‐free fusion technique was developed to analyse major and trace element compositions of silicate rocks. The sample powders were melted in a molybdenum capsule sealed in a graphite tube to make a homogenous glass in a temperature‐controlled one‐atmosphere furnace. The glass was then measured for both major and trace element concentrations by LA‐ICP‐MS using a calibration strategy of total metal‐oxide normalisation. The optimum conditions (i.e., temperature and duration) to make homogeneous glasses were obtained by performing melting experiments using a series of USGS reference materials including BCR‐2, BIR‐1, BHVO‐2, AGV‐1, AGV‐2, RGM‐1, W‐2 and GSP‐2 with SiO2 contents from 47 to 73% m/m. Analytical results of the USGS reference materials using our method were generally consistent with the recommended values within a discrepancy of 5–10% for most elements. The routine precision of our method was generally better than 5–10% RSD. Compared with previous methods of LA‐ICP‐MS whole‐rock analyses, our flux‐free fusion method is convenient and efficient in making silicate powder into homogeneous glass. Furthermore, it limits contamination and loss of volatile elements during heating. Therefore, our new method has great potential to provide reliable and rapid determinations of major and trace element compositions for silicate rocks.  相似文献   

11.
A simple and accurate method for the determination of Cr, Ni, Cu and Zn at μg g?1 levels in milligram‐sized bulk silicate materials is reported using isotope dilution high‐resolution inductively coupled plasma‐mass spectrometry (HR‐ICP‐MS) with a flow injection system. Silicate samples with Cr, Ni, Cu and Zn spikes were digested with HF‐HBr and Br2, and subsequently decomposed at 518 K in a Teflon bomb. In this procedure, all sulfides and chromite, major hosts of these elements, were completely decomposed, thus allowing for isotope equilibration between the sample and spike. Magnesium and Al fluorides formed after the digestion of the sample were removed by centrifugation, and the supernatant was directly aspirated into a HR‐ICP‐MS at a mass resolution of 7500, where interfering oxide ions, ArO+, CaO+, TiO+, CrO+ and VO+, were separated from Cr+, Ni+, Cu+ and Zn+. No matrix effects were observed down to a dilution factor of 50. Detection limits for these elements in silicate samples were < 0.04 μg g?1. The effectiveness of the technique was demonstrated by the analysis of 13 to 40 mg test portions of USGS and GSJ silicate reference materials with a major element composition ranging from andesite to peridotite, in addition to 8‐23 mg of the Smithsonian reference Allende. Both the reproducibility and the deviation from the reference value for most reference materials of various rock types were < 9%, and thus confirm that the method gives accurate analytical results for small sample sizes over a wide range of Cr, Ni, Cu and Zn contents. This method is, therefore, suitable for analysing small and/or precious bulk samples, such as meteorites, mantle peridotites and mineral separates, and for the characterisation of silicate and sulfide minerals for use as calibration samples in secondary ion mass spectrometry or laser ablation ICP‐MS.  相似文献   

12.
采用HNO3-HClO4-HF常压消解、HNO3-H2O2-HF高压密闭消解、HNO3-H2O2微波消解,干法灰化后残渣用HNO3-HF-HClO4溶解等四种方法对植物样品进行前处理,使用电感耦合等离子体质谱(ICP-MS)对植物样品中的27种元素进行定量分析,探讨了不同前处理方法对ICP-MS测定植物样品中微量元素的影响。分析结果表明: HNO3-HClO4-HF常压消解使用大量试剂,污染环境,造成空白值高;在常压体系中HClO4的加入能提高样品的消解效率,但赶酸不完全,会造成复合离子对钒和砷的干扰;干法灰化过程中某些元素(硼、汞等)会损失;常压消解和高压密闭消解中加入HF能有效地提高铍、稀土、钇、钛、锑、铀等元素的回收率,但在蒸干赶HF的过程中,会造成硼和汞的损失,并且钢套的生锈会造成铬、镍空白值高。尽管没有一种方法能适用于所有元素的分析,但相比较而言,HNO3-H2O2微波消解体系操作简单,大部分元素(除铍、钛、锑、铋、稀土)能得到满意的结果,精密度(RSD)均小于10%(n=10),相对误差(RE)为-4.6%~13.6%。  相似文献   

13.
The analytical results for the modified river sediment, SdAR‐1 circulated in Round 31 of the GeoPT proficiency testing programme, revealed unexpected discrepancies for Zr, Y and most higher atomic number rare earth elements, in determinations made by ICP‐MS using acid attack digestion methods. This investigation compares these ICP‐MS results with those obtained for SdAR‐1 by three other methods: (a) ICP‐MS using fusion/sintering for sample digestion, (b) XRF analysis and (c) INAA. The distribution of results for the elements Rb, Sr, Ce, Y, Yb and Zr is examined and compared with those of the test material for Round 25 of GeoPT, Paraná basalt, HTB‐1. A substantial proportion (though not all) of Y, Yb and Zr determinations in SdAR‐1 by ICP‐MS/acid attack was variably low (sometimes very low) compared with other methods. A detailed evaluation of the procedures used to determine these results indicated that successful determinations by ICP‐MS/acid attack could be made if digestions were made at 180 °C for 48 hr using at least 2 ml HF per 100 mg of sample. We suggest that the more benign conditions (used by many laboratories) resulted in incomplete digestion of resistant minerals, such as zircon.  相似文献   

14.
This work provides a measurement procedure for the complete digestion of rock samples containing refractory minerals such as zircon and chromite. Their dissolution by wet acid digestion is often incomplete but, although providing complete digestions, alkali fusion techniques can result in solutions with a high blank and total dissolved solid content. It was established by the systematic study with reference material trachyandesite MTA‐1 that a 1:6 sample to sodium peroxide (Na2O2) ratio is conservative for the complete digestion and recovery of all the analytes especially those contained in zircon. The sample decomposition time was 120 min for the zircon‐bearing rhyolite reference material MRH‐1. Complete digestion of chromite was obtained in the harzburgite RM MUH‐1. The sample solutions were stable for at least 1 year. Accurate measurements of SiO2, Al2O3, TiO2, P2O5 and K2O could be made with ICP‐MS by not discarding the supernatant of the sinter solution and by using geological reference materials for external calibration. HF digestions are slow, not universal, and may form new mineral/phases that are insoluble under high temperature conditions. The validated sample decomposition procedure combined with ICP‐MS presents an alternative to the use of HF in routine analysis of difficult to digest geological materials.  相似文献   

15.
An efficient, clean procedure for the measurement of element mass fractions in bulk rock nanoparticulate pressed powder pellets (PPPs) by 193 nm laser ablation ICP‐MS is presented. Samples were pulverised by wet milling and pelletised with microcrystalline cellulose as a binder, allowing non‐cohesive materials such as quartz or ceramics to be processed. The LA‐ICP‐MS PPP analytical procedure was optimised and evaluated using six different geological reference materials (JP‐1, UB‐N, BCR‐2, GSP‐2, OKUM and MUH‐1), with rigorous procedural blank quantification employing synthetic quartz. Measurement trueness of the procedure was equivalent to that achieved by solution ICP‐MS and LA‐ICP‐MS analysis of glass. The measurement repeatability was as low as 0.5–2% (1s,= 6) and, accordingly, PPP homogeneity could be demonstrated. Calibration based on the reference glasses NIST SRM 610, NIST SRM 612, BCR‐2G and GSD‐1G revealed matrix effects for glass and PPP measurement with NIST SRM 61×; using basalt glasses eliminated this problem. Most significantly, trace elements not commonly measured (flux elements Li, B; chalcophile elements As, Sb, Tl, In, Bi) could be quantified. The PPP‐LA‐ICP‐MS method overcomes common problems and limitations in analytical geochemistry and thus represents an efficient and accurate alternative for bulk rock analysis.  相似文献   

16.
Sphalerite (ZnS) is an abundant ore mineral and an important carrier of elements such as Ge, Ga and In used in high‐technology applications. In situ measurements of trace elements in natural sphalerite samples using LA‐ICP‐MS are hampered by a lack of homogenous matrix‐matched sulfide reference materials available for calibration. The preparation of the MUL‐ZnS1 calibration material containing the trace elements V, Cr, Mn, Co, Ni, Cu, Ga, Ge, As, Se, Mo, Ag, Cd, In, Sn, Sb, Tl and Pb besides Zn, Fe and S is reported. Commercially available ZnS, FeS, CdS products were used as the major components, whereas the trace elements were added by doping with single‐element ICP‐MS standard solutions and natural mineral powders. The resulting powder mixture was pressed to pellets and sintered at 400 °C for 100 h using argon as an inert gas. To confirm the homogeneity of major and trace element distributions within the MUL‐ZnS1 calibration material, measurements were performed using EPMA, solution ICP‐MS, ICP‐OES and LA‐ICP‐MS. The results show that MUL‐ZnS‐1 is an appropriate material for calibrating trace element determination in sphalerite using LA‐ICP‐MS.  相似文献   

17.
利用电感耦合等离子体质谱法(ICP-MS)测定植物样品中微量元素的关键技术是消除植物样品的有机基体效应,本文通过预处理方法中的酸消解体系、称样量和消解方式消除其影响。以国家标准物质灌木枝叶组合样(GBW07603)为材料进行研究,对比分析了硝酸-过氧化氢、硝酸-氢氟酸、硝酸-氢氟酸-过氧化氢3种酸溶体系的消解效果,以确定最佳酸溶体系,进而定量研究2种称样量(50 mg和100 mg)和3种消解方式(密封高压二次消解、密封高压一次消解、微波消解)的消解效果,并以In作为内标采用ICP-MS测定微量元素含量。结果表明:硝酸-氢氟酸-过氧化氢酸溶体系的消解效果最好;50 mg的测定值更接近于参考值;微波消解法的测定值明显偏低,而密封高压二次消解法是灌木枝叶样品预处理的有效方法。  相似文献   

18.
Three synthetic reference glasses were prepared by directly fusing and stirring 3.8 kg of high‐purity oxide powders to provide reference materials for microanalytical work. These glasses have andesitic major compositions and are doped with fifty‐four trace elements in nearly identical abundance (500, 50, 5 µg g?1) using oxide powders or element solutions, and are named ARM‐1, 2 and 3, respectively. We further document that sector‐field (SF) ICP‐MS (Element 2 or Element XR) is capable of sweeping seventy‐seven isotopes (from 7Li to 238U, a total of sixty‐eight elements) in 1 s and, thus, is able to quantify up to sixty‐eight elements by laser sampling. Micro‐ and bulk analyses indicate that the glasses are homogeneous with respect to major and trace elements. This paper provides preliminary data for the ARM glasses using a variety of analytical techniques (EPMA, XRF, ICP‐OES, ICP‐MS, LA‐Q‐ICP‐MS and LA‐SF‐ICP‐MS) performed in ten laboratories. Discrepancies in the data of V, Cr, Ni and Tl exist, mainly caused by analytical limitations. Preliminary reference and information values for fifty‐six elements were calculated with uncertainties [2 relative standard error (RSE)] estimated in the range of 1–20%.  相似文献   

19.
Seven ilmenite (FeTiO3) megacrysts derived from alnöite pipes (Island of Malaita, Solomon Islands) were characterised for their major and trace element compositions in relation to their potential use as secondary reference materials for in situ microanalysis. Abundances of thirteen trace elements obtained by laser ablation ICP‐MS analyses (using the NIST SRM 610 glass reference material) were compared with those determined by solution‐mode ICP‐MS measurements, and these indicated good agreement for most elements. The accuracy of the LA‐ICP‐MS protocol employed here was also assessed by repeated analysis of MPI‐DING international glass reference materials ML3B‐G and KL2‐G. Several of the Malaitan ilmenite megacrysts exhibited discrepancies between laser ablation and solution‐mode ICP‐MS analyses, primarily attributed to the presence of a titano‐magnetite exsolution phase (at the grain boundaries), which were incorporated solely in the solution‐mode runs. Element abundances obtained by LA‐ICP‐MS for three of the ilmenite megacrysts (CRN63E, CRN63H and CRN63K) investigated here had RSD (2s) values of < 20% and therefore can be considered as working values for reference purposes during routine LA‐ICP‐MS analyses of ilmenite.  相似文献   

20.
Major and trace element compositions of fifteen silicate rock reference materials have been determined by a combined XRF and laser ablation ICP‐MS (LA‐ICP‐MS) technique on glasses prepared by fusing the sample with a lithium borate flux (sample:flux = 1:3). Advantages of this technique include the ability to measure major and trace element abundances on a single sample using a quick and simple preparation that attacks resistant phases such as zircon without the need for acid dissolution. The method is suitable for a wide variety of bulk compositions including mafic, intermediate and silicic rocks. Abundance‐normalized mass response patterns (the ratio of signal intensity to element concentration) of the LA‐ICP‐MS analyses vary systematically with major element composition, demonstrating the presence of a matrix effect that cannot be compensated by normalisation to a single internal standard element. Increasing the sampling distance between the ICP‐MS cone and the torch reduces the magnitude of this effect, suggesting that a mechanism related to residence time of ablated particles in the plasma may be at least partially responsible for the observed variations in mass response patterns. When using a matrix‐matched calibration, agreement of the LA‐ICP‐MS results with published reference values or those obtained by solution ICP‐MS is 10% relative. Analytical precision based on replicate analyses is typically 5% RSD. Procedural detection limits that include contributions from gas background and flux are 0.01‐0.1 μg g‐1 for the heavy mass trace elements (Rb‐U). Major element analyses by XRF show excellent agreement with results obtained using a conventional heavy element absorbing flux. High quality major and trace element data for silicate rocks can be achieved by a combined XRF and LA‐ICP‐MS analysis of Li2B4O7/LiBO2 fused glasses provided an appropriate matrix‐matched calibration is adopted.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号