首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The paper presents a dynamic response analysis of vertically excited liquid storage tanks including both liquid-tank and liquid-soil interaction. The system considered is a thin-walled, elastic cylindrical shell entirely filled with an incompressible and inviscid fluid, resting on a flexible foundation over an elastic halfspace with frequency dependent stiffness and damping parameters. The problem is treated analytically by the generalized-coordinate approach and then solved numerically using the complex frequency response analysis. For one special tank, natural frequencies and equivalent damping ratios are evaluated and compared with those corresponding to a rigid ground. The maximum dynamic pressure is calculated using the response spectra of the 1976 Friuli earthquake. A parameter study is carried out to show the great influence of variable soil stiffness upon the damping ratio of the shell-liquid-soil system.  相似文献   

2.
A method for parametric system identification of classically damped linear system in frequency domain is adopted and extended for non‐classically damped linear systems subjected up to six components of earthquake ground motions. This method is able to work in multi‐input/multi‐output (MIMO) case. The response of a two‐degree‐of‐freedom model with non‐classical damping, excited by one‐component earthquake ground motion, is simulated and used to verify the proposed system identification method in the single‐input/multi‐output case. Also, the records of a 10 storey real building during the Northridge earthquake is used to verify the proposed system identification method in the MIMO case. In this case, at first, a single‐input/multi‐output assumption is considered for the system and modal parameters are identified, then other components of earthquake ground motions are added, respectively, and the modal parameters are identified again. This procedure is repeated until all four components of earthquake ground motions which are measured at the base level of the building are included in the identification process. The results of identification of real building show that consideration of non‐classical damping and inclusion of the multi‐components effect of earthquake ground motions can improve the least‐squares match between the finite Fourier transforms of recorded and calculated acceleration responses. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

3.
The accurate analysis of the seismic response of isolated structures requires incorporation of the flexibility of supporting soil.However,it is often customary to idealize the soil as rigid during the analysis of such structures.In this paper,seismic response time history analyses of base-isolated buildings modelled as linear single degree-of-freedom(SDOF) and multi degree-of-freedom(MDOF) systems with linear and nonlinear base models considering and ignoring the flexibility of supporting soil are conducted.The flexibility of supporting soil is modelled through a lumped parameter model consisting of swaying and rocking spring-dashpots.In the analysis,a large number of parametric studies for different earthquake excitations with three different peak ground acceleration(PGA) levels,different natural periods of the building models,and different shear wave velocities in the soil are considered.For the isolation system,laminated rubber bearings(LRBs) as well as high damping rubber bearings(HDRBs) are used.Responses of the isolated buildings with and without SSI are compared under different ground motions leading to the following conclusions:(1) soil flexibility may considerably influence the stiff superstructure response and may only slightly influence the response of the flexible structures;(2) the use of HDRBs for the isolation system induces higher structural peak responses with SSI compared to the system with LRBs;(3) although the peak response is affected by the incorporation of soil flexibility,it appears insensitive to the variation of shear wave velocity in the soil;(4) the response amplifications of the SDOF system become closer to unit with the increase in the natural period of the building,indicating an inverse relationship between SSI effects and natural periods for all the considered ground motions,base isolations and shear wave velocities;(5) the incorporation of SSI increases the number of significant cycles of large amplitude accelerations for all the stories,especially for earthquakes with low and moderate PGA levels;and(6) buildings with a linear LRB base-isolation system exhibit larger differences in displacement and acceleration amplifications,especially at the level of the lower stories.  相似文献   

4.
A wavelet-based formulation has been presented in this paper for the stochastic analysis of a linear multi-degree-of-freedom (MDOF) classically damped system subjected to earthquake ground motion. The ground motion has been modelled as a non-stationary process (both in amplitude and frequency) using wavelets. Closed-form expressions of the moments of the instantaneous Power Spectral Density Function (PSDF) of the response have been derived and used to predict the statistics of the response peak of any desired order. For illustration of the formulation, an example torsionally coupled multistoried building has been considered along with the twenty synthetically generated time-histories corresponding to an example ground motion process. © 1997 John Wiley & Sons, Ltd.  相似文献   

5.
Investigated is the accuracy in estimating the response of asymmetric one‐storey systems with non‐linear viscoelastic (VE) dampers by analysing the corresponding linear viscous system wherein all non‐linear VE dampers are replaced by their energy‐equivalent linear viscous dampers. The response of the corresponding linear viscous system is determined by response history analysis (RHA) and by response spectrum analysis (RSA) extended for non‐classically damped systems. The flexible and stiff edge deformations and plan rotation of the corresponding linear viscous system determined by the extended RSA procedure is shown to be sufficiently accurate for design applications with errors generally between 10 and 20%. Although similar accuracy is also shown for the ‘pseudo‐velocity’ of non‐linear VE dampers, the peak force of the non‐linear VE damper cannot be estimated directly from the peak damper force of the corresponding linear viscous system. A simple correction for damper force is proposed and shown to be accurate (with errors not exceeding 15%). For practical applications, an iterative linear analysis procedure is developed for determining the amplitude‐ and frequency‐dependent supplemental damping properties of the corresponding linear viscous system and for estimating the response of asymmetric one‐storey systems with non‐linear VE dampers from the earthquake design (or response) spectrum. Finally, a procedure is developed for designing non‐linear supplemental damping systems that satisfy given design criteria for a given design spectrum. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

6.
A one-dimensional equivalent linear method (EQL) is widely used in estimating seismic ground response. For this method, the shear modulus and damping ratio of inelastic soil are supposed to be frequency independent. However, historical earthquake records and laboratory test results indicate that nonlinear soil behavior is frequency-dependent. Several frequency-dependent equivalent linear methods (FDEQL) related to the Fourier amplitude of shear strain time history have been developed to take into account the frequency-dependent soil behavior. Furthermore, the shear strain threshold plays an important role in soil behavior. For shear strains below the elastic shear strain threshold, soil behaves essentially as a linear elastic material. To consider the effect of elastic-shear-strain-threshold- and frequency-dependent soil behavior on wave propagation, the shear-strain-threshold- and frequency-dependent equivalent linear method (TFDEQL) is proposed. A series of analyses is implemented for EQL, FDEQL, and TFDEQL methods. Results show that elastic-shear-strain-threshold- and frequency-dependent soil behavior plays a great influence on the computed site response, especially for the high-frequency band. Also, the effect of elastic-strain-threshold- and frequency-dependent soil behavior on the site response is analyzed from relatively weak to strong input motion, and results show that the effect is more pronounced as input motion goes from weak to strong.  相似文献   

7.
The seismic response of the Mexico City Cathedral built of very soft soil deposits is evaluated by using motions recorded in various parts of the structure during several moderate earthquakes. This unique set of records provides significant insight into the seismic response of this and other similar historic stone masonry structures. Free‐field ground motions are carefully compared in time and frequency domains with motions recorded at building basement. The dynamic characteristics of the structure are inferred from the earthquake records by using system identification techniques. Variation of seismic response for different seismic intensities is discussed. It is shown that, due to the soil–structure interaction, due to large differences between dominant frequencies of earthquake ground motions at the site and modal frequencies of vibration of the structure, and due to a particularly high viscous damping, seismic amplifications of ground motion in this and similar historic buildings erected on soft soil deposits are much smaller than that induced in most modern constructions. Nevertheless, earthquake records and analytical results show that several components of the structure such as its central dome and the bell towers may be subjected to local vibrations that significantly amplify ground motions. Overall, results indicate that in its present state the structure has an acceptable level of seismic safety. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

8.
The damping reduction factors are used in a few building codes in order to estimate the elastic response spectrum with high damping ratios from its 5%‐damped counterpart. At present, much research regarding this factor has been published. The purpose of this paper is to evaluate the accuracy of five different models of damping reduction factors. In addition, the damping reduction factors adopted in the recent U.S.A. seismic codes are also evaluated. Statistical studies are carried out according to a total of 216 earthquake ground motions recorded on firm sites in California. Considered here are elastic single‐degree‐of‐freedom (SDOF) systems with natural vibrating periods between 0.1 and 6.0 s. Mean ratios and dispersion of approximate to exact maximum elastic displacement demands corresponding to various damping reduction factors are computed as functions of the natural vibrating period and the viscous damping ratio. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

9.
On the basis of some simplifying assumptions, a parametric analysis is made of the interaction effects on the effective period and damping of structures with embedded foundation in a soil layer. A simplified three-dimensional interaction model is used, in which the depth of a cylindrical foundation, the degree of contact between the ground and the footing walls and the depth of a homogeneous stratum over rigid rock are considered variable. The soil is replaced with impedance functions that are taken from a data base obtained with an appropriate numerical technique, so that suitable springs and -pots dependent on the excitation frequency are used. The system period and system damping are determined from the steady-state response of an equivalent single oscillator with flexible base subjected to a harmonic motion with constant amplitude, by equating its resonant response with that of a replacement oscillator with rigid base excited with the same motion. The influence of the foundation embedment and soil layer is investigated for several depths of both the footing and the stratum.It is confirmed that the system period decreases and the system damping increases with the foundation embedment only for sidewalls extending along the entire foundation depth. For embedded footings without sidewall or with sidewall in null contact with the surrounding soil, the effective system parameters behave opposite to those corresponding to the interface condition of total contact. Also, the system damping increases significantly with the layer depth, while the system period is practically insensitive to variations of this characteristic parameter. Finally, introducing additional permissible simplifications, an improved approximate solution for the effective period and damping of coupled systems is presented, which differs from previous analogous approximations in that damping factors of second order are not neglected and the foundation depth is explicitly considered.  相似文献   

10.
A set of reinforced concrete structures with gravitational loads and mechanical properties (strength and stiffness) representative of systems designed for earthquake resistance in accordance with current criteria and methods is selected to study the influence of dynamic soil–structure interaction on seismic response, ductility demands and reliability levels. The buildings are considered located at soft soil sites in the Valley of Mexico and subjected to ground motion time histories simulated in accordance with characteristic parameters of the maximum probable earthquake likely to occur during the system's expected life. For the near‐resonance condition the effects of soil–structure interaction on the ductility demands depend mainly on radiation damping. According to the geometry of the structures studied this damping is strongly correlated with the aspect ratio, obtained by dividing the building height by its width. In this way, for structures with aspect ratio greater than 1.4 the storey and global ductility demands increase with respect to those obtained with the same structures but on rigid base, while for structures with aspect ratio less than 1.4 the ductility demands decrease with respect to those for the structures on rigid base. For the cases when the fundamental period of the structure has values very different from the dominant ground period, soil–structure interaction leads in all cases to a reduction of the ductility demands, independently of the aspect ratio. The reliability index β is obtained as a function of the base shear ratio and of the seismic intensity acting on the nonlinear systems subjected to the simulated motions. The resulting reliability functions are very similar for systems on rigid or on flexible foundation, provided that in the latter case the base rotation and the lateral displacement are removed from the total response of the system. Copyright © 2006 John Wiley & Sons, Ltd.  相似文献   

11.
The system damping, the system frequency, the relative building response and the base rocking response peak amplitudes are studied, as those depend on the building mass and height, the flexibility of the soil, the structural damping, the type of incident waves and their angle of incidence. A linear two-dimensional model is used, which assumes the soil to be a homogeneous isotropic half-space, the foundation supporting the building to be a rigid embedded cylinder, and in which the building model is an equivalent single-degree-of-freedom oscillator. The system frequency and the system damping ratio are determined by measuring the width and the frequency of the peak in the transfer function of the oscillator relative response, using the analogy with the half-power method for a single-degree-of-freedom fixed-base oscillator. Previous similar studies are for dynamic soil-structure interaction only, and for simplified models in which the stiffness of the soil and the damping due to radiation are represented by springs and dashpots. The study in this paper differs from the previous studies in that the wave passage effects (or the kinematic interaction) are also included, and that no additional simplifications of the model are made. Results are shown for excitation by plane P- and SV-waves.  相似文献   

12.
This paper describes the identification of finite dimensional, linear, time‐invariant models of a 4‐story building in the state space representation using multiple data sets of earthquake response. The building, instrumented with 31 accelerometers, is located on the University of California, Irvine campus. Multiple data sets, recorded during the 2005 Yucaipa, 2005 San Clemente, 2008 Chino Hills and 2009 Inglewood earthquakes, are used for identification and validation. Considering the response of the building as the output and the ground motion as the input, the state space models that represent the underlying dynamics of the building in the discrete‐time domain corresponding to each data set are identified. The time‐domain Eigensystem Realization Algorithm with the Observer/Kalman filter identification procedure are adopted in this paper, and the modal parameters of the identified models are consistently determined by constructing stabilization diagrams. The four state space models identified demonstrate that the response of the building is amplitude dependent with the response frequency and damping, being dependent on the magnitude of ground excitation. The practical application of this finding is that the consistency of this building response to future earthquakes can be quickly assessed, within the range of ground excitations considered (0.005g–0.074g), for consistency with prior response—this assessment of consistent response is discussed and demonstrated with reference to the four earthquake events considered in this study. Inclusion of data sets relating to future earthquakes will enable the findings to be extended to a wider range of ground excitation magnitudes. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

13.
土体参数对地表加速度峰值和反应谱的影响   总被引:9,自引:1,他引:8  
运用一维土层地震反应的等效线性化波动方法,研究了单层均质土密度、动剪切模量比和阻尼比、土层厚度和土层剪切波速等参数变化对土层地表加速度峰值和反应谱的影响,所得到的结论对于指导地震安全性评价中的勘察试验工作、提高土层地震反应的计算精度具有一定的参考价值。  相似文献   

14.
Numerical simulations of a single‐degree‐of‐freedom (SDOF) structure, rigidly supporting a tuned liquid damper (TLD) and subjected to both real and artificially generated earthquake ground motions, show that a properly designed TLD can significantly reduce the structure's response to these motions. The TLD is a rigid, rectangular tank with shallow water in it. Its fundamental linear sloshing frequency is tuned to the structure's natural frequency. The TLD is more effective in reducing structural response as the ground excitation level increases. This is because it then dissipates more energy due to sloshing and wave breaking. A larger water‐depth to tank‐length ratio than previous studies suggested, which still falls within the constraint of shallow water theory, is shown to be more suitable for excitation levels expected in strong earthquake motions. A larger water‐mass to structure‐mass ratio is shown to be required for a TLD to remain equally effective as structural damping increases. Furthermore, the reduction in response is seen to be fairly insensitive to the bandwidth of the ground motion but is dependent on the structure's natural frequency relative to the significant ground frequencies. Finally, a practical approach is suggested for the design of a TLD to control earthquake response. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

15.
The problem of soil–structure interaction analysis with the direct method is studied. The direct method consists of explicitly modeling the surrounding soil to bedrock and the structure resting on the soil. For the soil medium, usually the traditional equivalent linear method with a reduced shear modulus and an increased damping ratio for the soil is used. However, this method does not work in the vicinity of foundation where the soil behavior is highly nonlinear because of presence of large strains. This research proposes a modified equivalent linear method with a further reduction of the soil shear modulus in the near-field of foundation that results in validity of using the equivalent linear method throughout. For regular short, intermediate and tall structures resting on such soft soils, a series of dynamic time-history analysis is implemented using earthquake records scaled to a sample design spectrum and the nonlinear structural responses are compared for different assumptions of soil behavior including the elasto-plastic Mohr–Coulomb, the traditional equivalent linear, and the proposed modified equivalent linear method. This analysis validates the proposed method.  相似文献   

16.
It is demonstrated that the addition of a tuned mass-spring-dashpot system with a relatively small mass and a high damping ratio can be an effective way to increase the inherent damping characteristics of buildings and reduce, thus, their response to earthquake excitations. The demonstration is based on a theoretical formulation and on numerical and experimental studies that confirm this formulation. In the theoretical formulation, it is shown first that, if certain conditions are satisfied, the damping ratios in two of the modes of the system that is formed by a building and an appendage in resonance are approximately equal to the average of the corresponding damping ratios of the building and the appendage. Based on this finding, it is then shown that an attached appendage with a high damping ratio and tuned to the fundamental frequency of a building may increase the damping ratio in the fundamental mode of the building to a value close to half the damping ratio of the appendage. In the numerical study, the response of a ten-storey shear building is analysed under two different earthquake ground motions with and without the proposed resonant appendages. Appendages with damping ratios of 20 and 30 per cent are considered. In this study, it is found that under one of the ground motions the maximum displacement of the building's roof is reduced 30 per cent with the appendage with 20 per cent damping and 39 per cent with the one with 30 per cent damping. Similarly, with these two appendages the building's base shear is reduced 31 and 41 per cent, respectively. In the experimental study, a wooden three-storey structural model is tested in a shaking table with and without an appendage designed and constructed to have a damping ratio of 53-5 per cent. The test is conducted under random and sinusoidal base excitations. In the shaking table test under random excitation, the attached appendage reduces the response of the model 38-6 per cent, while in that under sinusoidal vibration 45-2 per cent.  相似文献   

17.
A base-isolated building is liable to have a small horizontal eccentricity between the centre of mass of the superstructure and the centre of rigidity of the supporting bearings. In seismic analysis, the structure is modelled as a rigid block with tributary masses supported on massless elastomeric rubber bearings placed at a constant elevation below the centre of mass. This simplified system has three degrees of freedom: two translations and one rotation in the vertical plane. The investigation of the dynamic behaviour of a base-isolated building is carried out for both the detuned and the perfectly tuned cases. In the detuned case, the natural frequencies of the system are assumed to be well separated. In the perfectly tuned case, the uncoupled rocking frequency is assumed to be identical to the vertical translational frequency, which may result from an unusual mass distribution and/or an extreme aspect ratio of the superstructure. Perturbation methods are implemented in finding the dynamic characteristics for both cases. However, the dynamic response of the perfectly tuned case is the major concern in this investigation. The Green's functions for the displacement response of the three-degree-of-freedom system are derived for both the undamped and damped conditions. The response spectrum modal superposition method is used in estimating the maximum acceleration response. A simple method, accounting for the effect of closely spaced modes, is proposed for combining modal maxima and results in an approximate solution corresponding to a single-degree-of-freedom system. This approximate solution may be used for the preliminary design of a base-isolated structure. Numerical results for a base-isolated building subjected to the vertical component of the El Centro earthquake of 1940 were carried out for comparison with these analytical results. The proposed modal combination method showed superiority over the conventional Square Root of the Sum of the Squares method in estimating maximum responses. The results also indicated that the approximate single-degree-of-freedom system yields accurate estimations. It is shown that the effect of rocking coupling on the vertical response of base-isolated structures subjected to transient loadings, such as earthquake motions, can generally be neglected as a result of the combined effects of the time lag between the maximum translational and rotational responses and the influence of damping in the isolation system, which for elastomeric bearings can be as high as 8 to 10 per cent of critical.  相似文献   

18.
A statistical approach is proposed for nonlinear surface ground analysis. In contrast to the conventional method which deals with only a single ground motion for equivalent linearization of soil properties, a design response spectrum defined at the upper level (bottom of the surface ground) of an engineering bedrock can be handled as the target design earthquake in the present paper. The effective shear strain in each soil layer is evaluated by means of a statistical procedure in which the mean peak shear strain is computed in terms of its standard deviation and the corresponding peak factor. The stiffness and damping ratio of each soil layer are obtained iteratively from the nonlinear relation of stiffness reduction factors and damping ratios with respect to the strain level. After the evaluation of the equivalent stiffness and damping ratio of every soil layer, the ground surface response spectrum is transformed from the design response spectrum defined at the upper level of the engineering bedrock via the one-dimensional wave propagation theory. The reliability and accuracy of the proposed analysis method is examined through the comparison with the results by the conventional method (represented by the program) for many simulated spectrum-compatible ground motions.  相似文献   

19.
An analysis is made of the steady-state response of a bilinear hysteretic structure supported on the surface of a viscoelastic half-space. The method of equivalent linearization is used to solve the equations of motion, and simplified approximate formulas are obtained for the fundamental resonant frequency of the system and for an effective critical damping ratio. Numerical results indicate that for non-linear hysteretic structures compliance of the soil foundation may lead to larger displacements than would occur if the base were rigid. This behaviour differs from that generally observed for linear systems, for which the effect of soil-structure interaction is to reduce the rigid-base response.  相似文献   

20.
A systematic method for optimal added damper placement in building structures is developed, taking into account the response amplification due to the surface ground. Non-linear amplification of the surface ground is described by an equivalent linear model. Hysteretic damping of the surface ground and radiational damping into the semi-infinite visco-elastic ground are included in the model. An original steepest direction search algorithm is applied to the interaction model. Closed-form expressions of the inverse of the coefficient matrix (tri-diagonal matrix) enable one to compute the transfer function and its derivative with respect to design variables very efficiently. It is shown that the ratio of the fundamental natural period of the structure to that of the surface ground is a key parameter for characterizing the optimal damper placement. Several examples for different soil conditions are presented to demonstrate the effectiveness and validity of the present method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号