1.
Ceric A  Haitjema H 《Ground water》2005,43(3):408-412
As part of its Wellhead Protection Program, the U.S. EPA mandates the delineation of "time-of-travel capture zones" as the basis for the definition of wellhead protection zones surrounding drinking water production wells. Depending on circumstances the capture zones may be determined using methods that range from simply drawing a circle around the well to sophisticated ground water flow and transport modeling. The simpler methods are attractive when faced with the delineation of hundreds or thousands of capture zones for small public drinking water supply wells. On the other hand, a circular capture zone may not be adequate in the presence of an ambient ground water flow regime. A dimensionless time-of-travel parameter T is used to determine when calculated fixed-radius capture zones can be used for drinking water production wells. The parameter incorporates aquifer properties, the magnitude of the ambient ground water flow field, and the travel time criterion for the time-of-travel capture zone. In the absence of interfering flow features, three different simple capture zones can be used depending on the value of T . A modified calculated fixed-radius capture zone proves protective when T < 0.1, while a more elongated capture zone must be used when T > 1. For values of T between 0.1 and 1, a circular capture zone can be used that is eccentric with respect to the well. Finally, calculating T allows for a quick assessment of the validity of circular capture zones without redoing the delineation with a computer model.  相似文献   

2.
Delineation of regional arid karstic aquifers: an integrative data approach   总被引:1,自引:0,他引:1  
This research integrates data procedures for the delineation of regional ground water flow systems in arid karstic basins with sparse hydrogeologic data using surface topography data, geologic mapping, permeability data, chloride concentrations of ground water and precipitation, and measured discharge data. This integrative data analysis framework can be applied to evaluate arid karstic aquifer systems globally. The accurate delineation of ground water recharge areas in developing aquifer systems with sparse hydrogeologic data is essential for their effective long-term development and management. We illustrate the use of this approach in the Cuatrociénegas Basin (CCB) of Mexico. Aquifers are characterized using geographic information systems for ground water catchment delineation, an analytical model for interbasin flow evaluation, a chloride balance approach for recharge estimation, and a water budget for mapping contributing catchments over a large region. The test study area includes the CCB of Coahuila, Mexico, a UNESCO World Biosphere Reserve containing more than 500 springs that support ground water-dependent ecosystems with more than 70 endemic organisms and irrigated agriculture. We define recharge areas that contribute local and regional ground water discharge to springs and the regional flow system. Results show that the regional aquifer system follows a topographic gradient that during past pluvial periods may have linked the Río Nazas and the Río Aguanaval of the Sierra Madre Occidental to the Río Grande via the CCB and other large, currently dry, upgradient lakes.  相似文献   

3.
The U.S. Environmental Protection Agency has established several methods to delineate wellhead protection areas (WHPAs) around community wells in order to protect them from surface contamination sources. Delineating a WHPA often requires defining the capture zone for a well. Generally, analytical models or arbitrary setback zones have been used to define the capture zone in areas where little is known about the distribution of hydraulic head, hydraulic conductivity, or recharge. Numerical modeling, however, even in areas of sparse data, offers distinct advantages over the more simplified analytical models or arbitrary setback zones. The systematic approach discussed here calibrates a numerical flow model to regional topography and then applies a matrix of plausible recharge to hydraulic conductivity ratios ( R / K ) to investigate the impact on the size and shape of the capture zone. This approach does not attempt to determine the uncertainty of the model but instead yields several possible capture zones, the composite of which is likely to contain the actual capture zone. A WHPA based on this composite capture zone will protect ground water resources better than one based on any individual capture zone. An application of the method to three communities illustrates development of the R / K matrix and demonstrates that the method is particularly well suited for determining capture zones in alluvial aquifers.  相似文献   

4.
Patterns and Age Distribution of Ground-Water Flow to Streams   总被引:2,自引:0,他引:2  
Simulations of ground-water flow in a generic aquifer system were made to characterize the topology of ground-water flow in the stream subsystem and to evaluate its relation to deeper ground-water flow. The flow models are patterned after hydraulic characteristics of aquifers of the Atlantic Coastal Plain and are based on numerical solutions to three-dimensional, steady-state, unconfined flow. The models were used to evaluate the effects of aquifer horizontal-to-vertical hydraulic conductivity ratios, aquifer thickness, and areal recharge rates on flow in the stream subsystem. A particle tracker was used to determine flow paths in a stream subsystem, to establish the relation between ground-water seepage to points along a simulated stream and its source area of flow, and to determine ground-water residence time in stream subsystems. In a geometrically simple aquifer system with accretion, the source area of flow to streams resembles an elongated ellipse that tapers in the down gradient direction. Increased recharge causes an expansion of the stream subsystem. The source area of flow to the stream expands predominantly toward the stream headwaters. Base flow gain is also increased along the reach of the stream. A thin aquifer restricts ground-water flow and causes the source area of flow to expand near stream headwaters and also shifts the start-of-flow to the drainage basin divide. Increased aquifer anisotropy causes a lateral expansion of the source area of flow to streams. Ground-water seepage to the stream channel originates both from near- and far-recharge locations. The range in the lengths of flow paths that terminate at a point on a stream increase in the downstream direction. Consequently, the age distribution of ground water that seeps into the stream is skewed progressively older with distance downstream. Base flow ia an integration of ground water with varying age and potentially different water quality, depending on the source within the drainage basin. The quantitative results presented indicate that this integration can have a wide and complex residence time range and source distribution.  相似文献   

5.
Abstract

An analytical solution is developed to delineate the capture zone of a pumping well in an aquifer with a regional flow perpendicular to a stream, assuming a leaky layer between the stream and the aquifer. Three different scenarios are considered for different pumping rates. At low pumping rates, the capture zone boundary will be completely contained in the aquifer. At medium pumping rates, the tip of the capture zone boundary will intrude into the leaky layer. Under these two scenarios, all the pumped water is supplied from the regional groundwater flow in the aquifer. At high pumping rates, however, the capture zone boundary intersects the stream and pumped water is supplied from both the aquifer and the stream. The two critical pumping rates which separate these three scenarios, as well as the proportion of pumped water from the stream and the aquifer, are determined for different hydraulic settings.

Editor D. Koutsoyiannis; Associate editor A. Koussis

Citation Asadi-Aghbolaghi, M., Rakhshandehroo, G.R., and Kompani-Zare, M., 2013. An analytical approach to capture zone delineation for a well near a stream with a leaky layer. Hydrological Sciences Journal, 58 (8), 1813–1823.  相似文献   

6.
The capture efficiency map: the capture zone under time-varying flow   总被引:3,自引:0,他引:3  
Festger AD  Walter GR 《Ground water》2002,40(6):619-628
The capture zone or contributing area of a ground water extraction well can be defined as that portion of the aquifer from which the well draws its water. Accurate delineation of capture zones is important in many ground water remediation applications and in the definition of wellhead protection areas. Their mathematical delineation is often simplified by using quasi-steady-state models based on time-weighted average pumping rates and background hydraulic gradients. We present a new semianalytic approach for the definition of capture zones under transient-flow conditions. We then use this approach to evaluate the effects of time variations in the direction of the background hydraulic gradient on capture. Results are presented in the form of capture efficiency maps (CEMs). Although the area contributing to a given well is found to generally expand relative to the steady-state average capture zone when the gradient direction varies, the zone of 100% capture may expand or contract depending on site-specific conditions. We illustrate our CEM approach by applying it to the design of a plume containment system.  相似文献   

7.
Design Screening Tools for Passive Funnel and Gate Systems   总被引:1,自引:0,他引:1  
The funnel and gate remediation concept (Star and Cherry 1993) represents a promising, yet relatively under-developed, technology for the passive control and in situ remediation of contaminated ground water. Effective design and implementation of such a system may, however, prove difficult under conditions of large or unpredictable variations in contaminant migration or ground water flow.
Numerical modeling of two-dimensional ground water flow has been used to predict the hydraulic performance of passive, straight, or winged funnel and gate configurations over a range of hydrogeologic and ambient ground water flow conditions. The results of these analyses were used to construct generic correlation diagrams relating upstream capture zone or gale through put to the barrier, gale, and aquifer characteristics. These diagrams serve as useful screening tools to (1) quantitatively estimate the capture zone of pre-determined funnel and gale configurations, or (2) develop preliminary funnel and gale designs that will yield a desired capture zone, independent of aquifer characteristics.  相似文献   

8.
Domestic Well Capture Zone and Influence of the Gravel Pack Length   总被引:1,自引:0,他引:1  
Domestic wells in North America and elsewhere are typically constructed at relatively shallow depths and with the sand or gravel pack extending far above the intake screen of the well (shallow well seal). The source areas of these domestic wells and the effect of an extended gravel pack on the source area are typically unknown, and few resources exist for estimating these. In this article, we use detailed, high-resolution ground water modeling to estimate the capture zone (source area) of a typical domestic well located in an alluvial aquifer. Results for a wide range of aquifer and gravel pack hydraulic conductivities are compared to a simple analytical model. Correction factors for the analytical model are computed based on statistical regression of the numerical results against the analytical model. This tool can be applied to estimate the source area of a domestic well for a wide range of conditions. We show that an extended gravel pack above the well screen may contribute significantly to the overall inflow to a domestic well, especially in less permeable aquifers, where that contribution may range from 20% to 50% and that an extended gravel pack may lead to a significantly elongated capture zone, in some instances, nearly doubling the length of the capture zone. Extending the gravel pack much above the intake screen therefore significantly increases the vulnerability of the water source.  相似文献   

9.
Integrated geophysical and chemical study of saline water intrusion   总被引:3,自引:0,他引:3  
Choudhury K  Saha DK 《Ground water》2004,42(5):671-677
Surface geophysical surveys provide an effective way to image the subsurface and the ground water zone without a large number of observation wells. DC resistivity sounding generally identifies the subsurface formations-the aquifer zone as well as the formations saturated with saline/brackish water. However, the method has serious ambiguities in distinguishing the geological formations of similar resistivities such as saline sand and saline clay, or water quality such as fresh or saline, in a low resistivity formation. In order to minimize the ambiguity and ascertain the efficacy of data integration techniques in ground water and saline contamination studies, a combined geophysical survey and periodic chemical analysis of ground water were carried out employing DC resistivity profiling, resistivity sounding, and shallow seismic refraction methods. By constraining resistivity interpretation with inputs from seismic refraction and chemical analysis, the data integration study proved to be a powerful method for identification of the subsurface formations, ground water zones, the subsurface saline/brackish water zones, and the probable mode and cause of saline water intrusion in an inland aquifer. A case study presented here illustrates these principles. Resistivity sounding alone had earlier failed to identify the different formations in the saline environment. Data integration and resistivity interpretation constrained by water quality analysis led to a new concept of minimum resistivity for ground water-bearing zones, which is the optimum value of resistivity of a subsurface formation in an area below which ground water contained in it is saline/brackish and unsuitable for drinking.  相似文献   

10.
Fendek M  Fendekova M 《Ground water》2005,43(5):717-721
Estimation of available ground water is a basic aspect of ground water management. Mathematical modeling is one of the methods that can be effectively used to obtain such estimates. A numerical model was used to calculate available ground water in the Zohor depression-an aquifer transcending national boundaries between the Slovak Republic and Austria. The aquifer, formed by Quaternary sediments overlying Neogene sequences, is composed of various clays interbedded with layers of sand, gravel, sandstones, and conglomerates. The AQUA computer model package was used to simulate flow in the aquifer. For model compilation, the following data were used: (1) effective precipitation; (2) surface water levels in surface water gauging profiles; and (3) withdrawal amounts. Hydraulic parameters of the aquifer were estimated based on information from 86 wells located in the area. The model was verified using data on ground water levels from a monitoring network. The simulation of the aquifer system permitted the estimation of the available ground water in the study area, showing that an additional 587 L/s can be abstracted. Ground water inflows to the Morava River, which flows through the region, range from 745 to 3100 L/s.  相似文献   

11.
The progressive packer/zone sampling method was used to identify the bottom of a plume of volatile organic compounds (VOCs) in the parts-per-million (ppm) range using one well in each of three separate locations. The method involves progressively drilling a 20-foot length of borehole through casing, setting an inflatable packer at the top of the drilled zone, purging the zone of three volumes of water using the airlift method, sampling the zone in situ through the packer string using a bailer, then repeating the procedure.
A plume consisting of chlorinated VOCs, alcohols, and vinyl chloride occurs in a low-yielding fractured bedrock aquifer located in the Passaic Formation at a site in central New Jersey. The thickness of the plume in total VOC concentrations exceeding 1 ppm was determined using the progressive packer/zone sampling method to a depth of 200 feet. The first borehole was completed as a monitoring well in the "hottest" zone encountered during testing. Additional wells were then clustered with this exploratory well to delineate the plume in the parts-per-billion (ppb) range. Cross contamination from previously sampled zones was not a problem as long as total VOCs in the ppm range were targeted and the sample interval was properly purged.
Instead of using a multiple well cluster consisting of an indefinite number of wells to determine the bulk thickness of a plume at a specific location, information from one borehole may suffice during the exploratory phase. Costs to the client and cross contamination potential to the aquifer can be minimized by limiting the number of boreholes needed for vertical delineation.  相似文献   

12.
Sub-surface temperature fields may be considerably affected by active ground water systems, thereby seriously hampering the interpretation of heat flow data. Quantitative evaluation of the convective component of heat transfer is thus very important in cases such as large sedimentary basins with vast underground water circulation. We propose in this study a simple model of horizontal aquifer. This model was used to examine the effect of the lateral convection on the surface heat flow near the recharge zone of basinal margins. The perturbation of the heat flow field above the aquifer was calculated for various aquifer geometry and various flow velocities and the regional scale dependence of the perturbation on the hydraulic properties of the aquifer was demonstrated. The model was applied to the Bohemian Cretaceous Basin and it was shown that within a few kilometres from the recharge zones the observed surface heat flow may be underestimated by up to several tens of percent. The procedure was tested in two locations in this area, in an attempt to make hydrogeological corrections to the measured heat flow values in several boreholes.  相似文献   

13.
The delineation of well capture zones is a basic component of ground water protection. The conventional methodology for capture zone delineation is backward advective particle tracking, often applied under the assumption of a two-dimensional aquifer. The suitability of the conventional approach for complex heterogeneous multi-aquifer systems was investigated, using the Waterloo Moraine aquifer system as an example. It was found that the conventional approach produces irregular particle tracks that require judgment to interpret in a meaningful way, and it can raise questions that may affect the credibility of the capture zone delineation. As an alternative, the potentially powerful but little-used backward-in-time advective-dispersive transport approach was investigated. A key advantage of this approach is its capability to represent local heterogeneities through the dispersion term. The dispersion process has a natural smoothing effect that results in unambiguous capture zones without the need for interpretation, thus enhancing credibility. The question of capture zone validation is also addressed. The meaning of a three-dimensional capture zone is considered, and it is shown that a fully three-dimensional representation of the system is crucial for valid results. The distinction between the maximum extent capture zone and the surface capture zone is also explained. In the case of complex heterogeneous systems, advective particle tracking can be used as an initial screening tool, whereas the more realistic backward-transport modeling approach can be used for final capture-zone delineation.  相似文献   

14.
Suburban areas are subject to strong anthropogenic modifications, which can influence hydrological processes. Sewer systems, ditches, sewer overflow devices and retention basins are introduced and large surface areas are sealed off. The knowledge of accurate flow paths and watershed boundaries in these suburban areas is important for storm water management, hydrological modelling and hydrological data analysis. This study proposes a new method for the determination of the drainage network based on time efficient field investigations and integration of sewer system maps into the drainage network for small catchments of up to 10 km2. A new method is also proposed for the delineation of subcatchments and thus the catchment area. The subcatchments are delineated using a combination of an object‐oriented approach in the urban zone and geographical information system–based terrain analysis with flow direction forcing in the rural zone. The method is applied to the Chaudanne catchment, which belongs to the Yzeron river network and is located in the suburban area of Lyon, France. The resulting subcatchment map gives information about subcatchment response and contribution. The method is compared with six other automatic catchment delineation methods based on stream burning, flow direction forcing and calculation of subcatchments for inlet points. None of the automatic methods could correctly represent the catchment area and flow paths observed in the field. The watershed area calculated with these methods differs by as much as 25% from the area computed with the new method. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
Cross-well seismic reflection data, acquired from a carbonate aquifer at Port Mayaca test site near the eastern boundary of Lake Okeechobee in Martin County, Florida, are used to delineate flow units in the region intercepted by two wells. The interwell impedance determined by inversion from the seismic reflection data allows us to visualize the major boundaries between the hydraulic units. The hydraulic (flow) unit properties are based on the integration of well logs and the carbonate structure, which consists of isolated vuggy carbonate units and interconnected vug systems within the carbonate matrix. The vuggy and matrix porosity logs based on Formation Micro-Imager (FMI) data provide information about highly permeable conduits at well locations. The integration of the inverted impedance and well logs using geostatistics helps us to assess the resolution of the cross-well seismic method for detecting conduits and to determine whether these conduits are continuous or discontinuous between wells. A productive water zone of the aquifer outlined by the well logs was selected for analysis and interpretation. The ELAN (Elemental Log Analysis) porosity from two wells was selected as primary data and the reflection seismic-based impedance as secondary data. The direct and cross variograms along the vertical wells capture nested structures associated with periodic carbonate units, which correspond to connected flow units between the wells. Alternatively, the horizontal variogram of impedance (secondary data) provides scale lengths that correspond to irregular boundary shapes of flow units. The ELAN porosity image obtained by cokriging exhibits three similar flow units at different depths. These units are thin conduits developed in the first well and, at about the middle of the interwell separation region, these conduits connect to thicker flow units that are intercepted by the second well. In addition, a high impedance zone (low porosity) at a depth of about 275 m, after being converted to ELAN porosity, is characterized as a more confined low porosity structure. This continuous zone corresponds to a permeability barrier in the carbonate aquifer that separates the three connected conduits observed in the cokriging image. In the zones above and below this permeability barrier, the water production is very high, which agrees with water well observations at the Port Mayaca aquifer.  相似文献   

16.
Aquifer information carried by aquifer test data may be affected by the presence of a finite thickness skin around the wellbore. The mathematical treatment for an aquifer accounting for the skin zone can be characterized by five parameters, that is, the outer radius of the skin zone and the transmissivity and storativity for each of the skin and aquifer zones. Sensitivity analysis was performed to examine the ground water flow behavior in the skin and aquifer zones in terms of the constant-head test (CHT) data. The simulated annealing procedure was applied to simultaneously determine the skin and aquifer parameters from the analysis of CHT data. Toward the previously mentioned goals, four suites of CHT data were analyzed in this article. The analyses of wellbore flow rate at the test well and the specific drawdown at the observation well gave accurate estimates for the skin and aquifer parameters, respectively. Only the skin thickness and both the skin and the aquifer diffusivities could be accurately estimated from the analysis of drawdown data in the observation well. The estimates for all skin and aquifer parameters from the composite analysis of flow rate and drawdown data were the most accurate. The results of sensitivity analyses and parameter estimations provide instructive references in the analysis of the skin-affected CHT data.  相似文献   

17.
The effects of surface water flow system changes caused by constructing water‐conservation areas and canals in southeast Florida on groundwater quality under the Atlantic Coastal Ridge was investigated with numerical modeling. Water quality data were used to delineate a zone of groundwater with low total dissolved solids (TDS) within the Biscayne aquifer under the ridge. The delineated zone has the following characteristics. Its location generally coincides with an area where the Biscayne aquifer has high transmissivities, corresponds to a high recharge area of the ridge, and underlies a part of the groundwater mound formed under the ridge prior to completion of the canals. This low TDS groundwater appears to be the result of pre‐development conditions rather than seepage from the canals constructed after the 1950s. Numerical simulation results indicate that the time for low TDS groundwater under the ridge to reach equilibrium with high TDS surface water in the water‐conservation areas and Everglades National Park are approximately 70 and 60 years, respectively. The high TDS groundwater would be restricted to the water‐conservation areas and the park due to its slow eastward movement caused by small hydraulic gradients in Rocky Glades and its mixing with the low TDS groundwater under the high‐recharge area of the ridge. The flow or physical boundary conditions such as high recharge rates or low hydraulic conductivity layers may affect how the spatial distribution of groundwater quality in an aquifer will change when a groundwater flow system reaches equilibrium with an associated surface water flow system.  相似文献   

18.
The area under study covers 3500 km2 in the upstream part of the closed catchment basin of the salt crust of Uyuni. This crust is a remnant of the saline Lake Tauca, which covered the area about 15,000 years ago. In the downstream part of the aquifer, the Cl concentration of ground water and Cl content in the unsaturated zone exceed 20 meq/L and 18 kg/m2, respectively. With the present hydrological conditions under semiarid conditions, the ground water residence time in the study area exceeds 3000 years. Transient simulations over 11,000 years were made using initial conditions as the retreat of Lake Tauca and taking into account a low recharge during the arid mid-Holocene period. The modeling simulates ground water flow, Cl transport, and ground water residence time. It includes the evaporation from the aquifer that leads to the accumulation of chloride in the unsaturated zone. Results of the modeling are consistent with the observations if it is assumed that the Cl previously accumulated in the unsaturated zone was flushed back into the aquifer around 2000 years B.P., contemporaneously with the end of the arid period.  相似文献   

19.
The permeability of the Elkhorn fault zone,South Park,Colorado   总被引:5,自引:0,他引:5  
Marler J  Ge S 《Ground water》2003,41(3):321-332
The purposes of this study are to use both field and modeling approaches to characterize the permeability of a fault and to assess the role of the fault on regional ground water flow. The study subject is the Elkhorn fault, a low-angle reverse fault that brings Precambrian crystalline rocks over the sediments of Colorado's South Park Basin. The fault is hypothesized to act as a low-permeability barrier to flow, restricting interaction between the crystalline aquifer and the basin sediments. To test this hypothesis and to better predict the permeability structure of the fault, we synthesized geologic data to create a geologic model of the fault, conducted aquifer tests to estimate the hydrogeologic properties of the fault zone, and used ground water modeling to test the influence of a range of hydraulic properties for the fault zone on ground water flow in the region. Our study suggests that the fault is a low-permeability feature. Estimated heads are best matched to observations by modeling the fault as a 10-foot-thick interval of low-permeability fault gouge. Steady-state flow models show that much of the flow in the study area is topographically driven near land surface. Flow rates decrease with depth in the aquifers. In the footwall, ground water moves updip in the Michigan-San Isabel syncline to discharge in the South Park Basin. In the hanging wall, ground water moves east to a regional ground water divide. Sensitivity analyses indicate that hydraulic heads are most sensitive to changes in hydraulic conductivity and recharge.  相似文献   

20.
AGalerkin finite-element model coupled with a particle tracking routine was developed to analyze the flow and transport dynamics near a high-capacity irrigation well. The model was used to compute the head distribution around the pumping well, to determine the area of influence, and to define ground water flowlines during short-term pumping periods typical of those used to collect water quality samples from high-capacity wells. In addition to hypothetical example results, the model was used to qualitatively analyze data obtained from pump-and-sample experiments conducted in an unconfined alluvial aquifer within the Platte River valley of south-central Nebraska where nitrate-nitrogen (NO3-N) contamination is prevalent.
Simulation results of both the hypothetical and field cases suggest that short-term pumping events, impact a limited volume of aquifer. The area of influence and flowlines are affected by aquifer anisotropy, pumping rate, and well construction characteristics). Ground water above or below the screened intervals does not enter a partially penetrating well in anisotropic aquifers. In aquifers where NO3-N concentration varies vertically and horizontally, waler quality samples from an irrigation, or other high-capacity, well provide only limited information about ground water contamination. A numerical model is thus recommended for calculating the area of influence and determining flowlines around high-capacity wells so that information derived from water quality samples collected at the wellhead can be better interpreted.  相似文献   