1.
This paper presents analytical solutions for determining non-steady-state capture zones produced by a single recovery well and steady-state capture zones produced by multiple recovery wells. Analysis of non-steady-slate capture zones is based on the lime-dependent location of caplure zone stagnation points and the geometric similarity between steady-slate and non-steady-state capture zones. The analytical solution of steady-state capture zones is obtained from spatial variations of discharge potential across the capture zone boundary. Both capture zone analyses are based on the assumptions of uniform flow field with a constant hydraulic conductivity, the Dupuit assumption of insignificant vertical flow, a negligible delayed yield, and a fully penetrating well with a constant pumping rate. For a ground water pump-and-trcat remediation program, the pumping rate and well location design variables can be adjusted to ensure containment of the ground water contaminant plume.  相似文献   

2.
The capture efficiency map: the capture zone under time-varying flow   总被引:3,自引:0,他引:3  
Festger AD  Walter GR 《Ground water》2002,40(6):619-628
The capture zone or contributing area of a ground water extraction well can be defined as that portion of the aquifer from which the well draws its water. Accurate delineation of capture zones is important in many ground water remediation applications and in the definition of wellhead protection areas. Their mathematical delineation is often simplified by using quasi-steady-state models based on time-weighted average pumping rates and background hydraulic gradients. We present a new semianalytic approach for the definition of capture zones under transient-flow conditions. We then use this approach to evaluate the effects of time variations in the direction of the background hydraulic gradient on capture. Results are presented in the form of capture efficiency maps (CEMs). Although the area contributing to a given well is found to generally expand relative to the steady-state average capture zone when the gradient direction varies, the zone of 100% capture may expand or contract depending on site-specific conditions. We illustrate our CEM approach by applying it to the design of a plume containment system.  相似文献   

3.
The delineation of well capture zones is a basic component of ground water protection. The conventional methodology for capture zone delineation is backward advective particle tracking, often applied under the assumption of a two-dimensional aquifer. The suitability of the conventional approach for complex heterogeneous multi-aquifer systems was investigated, using the Waterloo Moraine aquifer system as an example. It was found that the conventional approach produces irregular particle tracks that require judgment to interpret in a meaningful way, and it can raise questions that may affect the credibility of the capture zone delineation. As an alternative, the potentially powerful but little-used backward-in-time advective-dispersive transport approach was investigated. A key advantage of this approach is its capability to represent local heterogeneities through the dispersion term. The dispersion process has a natural smoothing effect that results in unambiguous capture zones without the need for interpretation, thus enhancing credibility. The question of capture zone validation is also addressed. The meaning of a three-dimensional capture zone is considered, and it is shown that a fully three-dimensional representation of the system is crucial for valid results. The distinction between the maximum extent capture zone and the surface capture zone is also explained. In the case of complex heterogeneous systems, advective particle tracking can be used as an initial screening tool, whereas the more realistic backward-transport modeling approach can be used for final capture-zone delineation.  相似文献   

4.
The design of a pump and treat (P&T) system for the hydraulic control of a contaminated plume in a confined aquifer is presented here. Being the system designed for the emergency containment of a nonaqueous phase liquid plume, the evaluation of the system’s short-term efficiency was considered an important issue. For this reason, both time-related and ultimate capture zones were defined. They were traced using the automatic protection area (APA) model, a capture-zone delineation tool based on a hybrid forward-backward particle tracking algorithm, that provides an automatic post-processing encirclement of capture zones. Two simple indexes are here proposed for the evaluation of the performance of the hydraulic barrier, that is, the efficacy and efficiency indexes, calculated from the capture areas provided by APA. The discharge rates of the wells were dimensioned applying the APA algorithm, maximizing efficacy and efficiency of the barrier. Results proved both visually (via plotting of capture zones) and numerically (via calculation of the indexes) that the P&T system can provide a complete capture of the contaminated area and minimizes the volume of extracted water. Consequently, the APA algorithm was proved to be a useful tool in capture zone delineation. As a future perspective, it could be coupled with the real-time measurement of pumping rates and water levels and be implemented as a part of a tuning tool for the management of the hydraulic barrier.  相似文献   

5.
Ground water circulation wells (GCWs) provide an appealing alternative to typical pump-and-treat ground water remediation systems because of the inherent resource-conservative nature of the GCW systems. GCW performance prediction is challenging because the consideration of extraction and recharge in a single well is unusual for most practitioners, the technology is relatively new, and a meaningful body of literature has not been published. A three-part evaluation process using state-of-the-practice numerical ground water flow and mass transport models was developed for application during GCW pilot studies at the former Nebraska Ordnance Plant site. A small-scale ground water flow model was developed during the pilot study planning process to predict the system performance and to locate performance-measuring monitoring wells. Key predictions included the capture zone predicted to develop upgradient of the GCW, the downgradierit GCW recharge zone, and the circulation zone centered on the GCW. The flow model was subsequently verified using ground water elevation data and contaminant concentration data collected during pilot study operation. Aquifer parameters were reestimated as a result of the verification process. Those parameter values were used as input to a larger scale model, which was used to develop a remedial alternative consisting of multiple GCW systems.  相似文献   

6.
Zhou Y  Haitjema H 《Ground water》2012,50(5):799-803
Radial time-of-travel (TOT) capture zones have been evaluated for unconfined aquifers with and without recharge. The solutions of travel time for unconfined aquifers are rather complex and have been replaced with much simpler approximate solutions without significant loss of accuracy in most practical cases. The current "volumetric method" for calculating the radius of a TOT capture zone assumes no recharge and a constant aquifer thickness. It was found that for unconfined aquifers without recharge, the volumetric method leads to a smaller and less protective wellhead protection zone when ignoring drawdowns. However, if the saturated thickness near the well is used in the volumetric method a larger more protective TOT capture zone is obtained. The same is true when the volumetric method is used in the presence of recharge. However, for that case it leads to unreasonableness over the prediction of a TOT capture zone of 5 years or more.  相似文献   

7.
The U.S. Environmental Protection Agency has established several methods to delineate wellhead protection areas (WHPAs) around community wells in order to protect them from surface contamination sources. Delineating a WHPA often requires defining the capture zone for a well. Generally, analytical models or arbitrary setback zones have been used to define the capture zone in areas where little is known about the distribution of hydraulic head, hydraulic conductivity, or recharge. Numerical modeling, however, even in areas of sparse data, offers distinct advantages over the more simplified analytical models or arbitrary setback zones. The systematic approach discussed here calibrates a numerical flow model to regional topography and then applies a matrix of plausible recharge to hydraulic conductivity ratios ( R / K ) to investigate the impact on the size and shape of the capture zone. This approach does not attempt to determine the uncertainty of the model but instead yields several possible capture zones, the composite of which is likely to contain the actual capture zone. A WHPA based on this composite capture zone will protect ground water resources better than one based on any individual capture zone. An application of the method to three communities illustrates development of the R / K matrix and demonstrates that the method is particularly well suited for determining capture zones in alluvial aquifers.  相似文献   

8.
 In many countries, the setup of protection areas around every drinking water well was instituted at a national level in order to preserve the quality of water as well as the perennially of the resource. Wellhead protection surfaces have been defined using capture zones showing the area influenced by a well within a certain time. A stochastic method is developed for delineating time-related capture zones in fractured aquifers characterised by a low porosity and a high degree of fracturing. The flow velocity within the fractures is determined statistically depending on the distribution of the fracture features and the mass transfer solution is obtained through a particle tracking algorithm. Probabilistic capture zone curves are obtained as a function of the travel time of particles to the well and the percentage of particles apt to be extracted up to this time. A sensitivity study of fracture network parameters leads to the conclusion that orientations and aperture distribution of the fracture sets are of primary importance to the wellhead protection delineation.  相似文献   

9.
It is often necessary to estimate the zone of contribution to, or the capture zone developed by, pumped wells: for example, when evaluating pump-and-treat remedies and when developing wellhead protection areas for supply wells. Tonkin and Larson (2002) and Brochu and Marcotte (2003) describe a mapping-based method for estimating the capture zone of pumped wells, developed by combining universal kriging (kriging with a trend) with analytical expressions that describe the response of the potentiometric surface to certain applied stresses. This Methods Note describes (a) expansions to the techinque described by Tonkin and Larson (2002) ; (b) the concept of the capture frequency map (CFM), a technique that combines information from multiple capture zone maps into a single depiction of capture; (c) the development of a graphical user interface to facilitate the use of the methods described; and (d) the integration of these programs within the MapWindow geographic information system environment. An example application is presented that illustrates ground water level contours, capture zones, and a CFM prepared using the methods and software described.  相似文献   

10.
Design Screening Tools for Passive Funnel and Gate Systems   总被引:1,自引:0,他引:1  
The funnel and gate remediation concept (Star and Cherry 1993) represents a promising, yet relatively under-developed, technology for the passive control and in situ remediation of contaminated ground water. Effective design and implementation of such a system may, however, prove difficult under conditions of large or unpredictable variations in contaminant migration or ground water flow.
Numerical modeling of two-dimensional ground water flow has been used to predict the hydraulic performance of passive, straight, or winged funnel and gate configurations over a range of hydrogeologic and ambient ground water flow conditions. The results of these analyses were used to construct generic correlation diagrams relating upstream capture zone or gale through put to the barrier, gale, and aquifer characteristics. These diagrams serve as useful screening tools to (1) quantitatively estimate the capture zone of pre-determined funnel and gale configurations, or (2) develop preliminary funnel and gale designs that will yield a desired capture zone, independent of aquifer characteristics.  相似文献   

11.
12.
Horizontal wells or radial collector wells are used in shallow aquifers to enhance water withdrawal rates. Groundwater flow patterns near these wells are three-dimensional (3D), but difficult to represent in a 3D numerical model because of the high degree of grid refinement needed. However, for the purpose of designing water withdrawal systems, it is sufficient to obtain the correct production rate of these wells for a given drawdown. We developed a Cauchy boundary condition along a horizontal well in a Dupuit-Forchheimer model. Such a steady-state 2D model is not only useful for predicting groundwater withdrawal rates but also for capture zone delineation in the context of source water protection. A comparison of our Dupuit-Forchheimer model for a radial collector well with a 3D model yields a nearly exact production rate. Particular attention is given to horizontal wells that extend underneath a river. A comparison of our approach with a 3D solution for this case yields satisfactory results, at least for moderate-to-large river bottom resistances.  相似文献   

13.
The New Jersey Department of Environmental Protection's Technical Regulations require the horizontal and vertical delineation of contamination. Monitor wells screened at increasingly deeper intervals are used to delineate vertical contamination. In New Jersey, the open interval in a bedrock well cannot exceed 7.6 m. Since contamination has been found at depths as great as 91.4 m in a production well in the study area, it would be prohibitively expensive to install monitor wells with 7.6 m open holes at ever-increasing depths until no contamination was found. Isolation of discrete zones in boreholes using pneumatic packers was implemented at a site in north central New Jersey. Ground water samples were collected from selected 6.1 m sections of boreholes drilled into fractured bedrock at three locations on the property and one offsite location. The ground water samples were analyzed in a field laboratory. The analytical results were used to determine the vertical extent of gasoline-related compounds dissolved in the ground water on the property and offsite. These compounds include benzene, ethylbenzene, methyl tertiary butyl ether, toluene, and xylenes. The four boreholes were converted into bedrock monitor wells. The intake interval for each of the wells was selected through evaluation of the vertical distribution of contaminants as determined from analytical results obtained from a field laboratory located onsite. Three wells are used for the recovery of contaminated ground water. The recovered water will be treated at the onsite air-stripping unit. The fourth well is used to chemically and hydraulically monitor the progress of the ground water recovery program.  相似文献   

14.
Geochemical data indicate that the Springfield Plateau aquifer, a carbonate aquifer of the Ozark Plateaus Province in central USA, has two distinct hydrochemical zones. Within each hydrochemical zone, water from springs is geochemically and isotopically different than water from wells. Geochemical data indicate that spring water generally interacts less with the surrounding rock and has a shorter residence time, probably as a result of flowing along discrete fractures and solution openings, than water from wells. Water type throughout most of the aquifer was calcium bicarbonate, indicating that carbonate‐rock dissolution is the primary geochemical process occurring in the aquifer. Concentrations of calcium, bicarbonate, dissolved oxygen and tritium indicate that most ground water in the aquifer recharged rapidly and is relatively young (less than 40 years). In general, field‐measured properties, concentrations of many chemical constituents, and calcite saturation indices were greater in samples from the northern part of the aquifer (hydrochemical zone A) than in samples from the southern part of the aquifer (hydrochemical zone B). Factors affecting differences in the geochemical composition of ground water between the two zones are difficult to identify, but could be related to differences in chert content and possibly primary porosity, solubility of the limestone, and amount and type of cementation between zone A than in zone B. In addition, specific conductance, pH, alkalinity, concentrations of many chemical constituents and calcite saturation indices were greater in samples from wells than in samples from springs in each hydrochemical zone. In contrast, concentrations of dissolved oxygen, nitrite plus nitrate, and chloride generally were greater in samples from springs than in samples from wells. Water from springs generally flows rapidly through large conduits with minimum water–rock interactions. Water from wells flow through small fractures, which restrict flow and increase water–rock interactions. As a result, springs tend to be more susceptible to surface contamination than wells. The results of this study have important implications for the geochemical and hydrogeological processes of similar carbonate aquifers in other geographical locations. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

15.
High-resolution slug testing   总被引:1,自引:0,他引:1  
The hydraulic conductivity (K) variation has important ramifications for ground water flow and the transport of contaminants in ground water. The delineation of the nature of that variation can be critical to complete characterization of a site and the planning of effective and efficient remedial measures. Site-specific features (such as high-conductivity zones) need to be quantified. Our alluvial field site in the Kansas River valley exhibits spatial variability, very high conductivities, and nonlinear behavior for slug tests in the sand and gravel aquifer. High-resolution, multilevel slug tests have been performed in a number of wells that are fully screened. A general nonlinear model based on the Navier-Stokes equation, nonlinear frictional loss, non-Darcian flow, acceleration effects, radius changes in the wellbore, and a Hvorslev model for the aquifer has been used to analyze the data, employing an automated processing system that runs within the Excel spreadsheet program. It is concluded that slug tests can provide the necessary data to identify the nature of both horizontal and vertical K variation in an aquifer and that improved delineation or higher resolution of K structure is possible with shorter test intervals. The gradation into zones of higher conductivity is sharper than seen previously, and the maximum conductivity observed is greater than previously measured. However, data from this project indicate that well development, the presence of fines, and the antecedent history of the well are important interrelated factors in regard to slug-test response and can prevent obtaining consistent results in some cases.  相似文献   

16.
Integrated geophysical and chemical study of saline water intrusion   总被引:3,自引:0,他引:3  
Choudhury K  Saha DK 《Ground water》2004,42(5):671-677
Surface geophysical surveys provide an effective way to image the subsurface and the ground water zone without a large number of observation wells. DC resistivity sounding generally identifies the subsurface formations-the aquifer zone as well as the formations saturated with saline/brackish water. However, the method has serious ambiguities in distinguishing the geological formations of similar resistivities such as saline sand and saline clay, or water quality such as fresh or saline, in a low resistivity formation. In order to minimize the ambiguity and ascertain the efficacy of data integration techniques in ground water and saline contamination studies, a combined geophysical survey and periodic chemical analysis of ground water were carried out employing DC resistivity profiling, resistivity sounding, and shallow seismic refraction methods. By constraining resistivity interpretation with inputs from seismic refraction and chemical analysis, the data integration study proved to be a powerful method for identification of the subsurface formations, ground water zones, the subsurface saline/brackish water zones, and the probable mode and cause of saline water intrusion in an inland aquifer. A case study presented here illustrates these principles. Resistivity sounding alone had earlier failed to identify the different formations in the saline environment. Data integration and resistivity interpretation constrained by water quality analysis led to a new concept of minimum resistivity for ground water-bearing zones, which is the optimum value of resistivity of a subsurface formation in an area below which ground water contained in it is saline/brackish and unsuitable for drinking.  相似文献   

17.
Comparative study of methods for WHPA delineation   总被引:3,自引:0,他引:3  
Human activities, whether agricultural, industrial, commercial, or domestic, can contribute to ground water quality deterioration. In order to protect the ground water exploited by a production well, it is essential to develop a good knowledge of the flow system and to adequately delineate the area surrounding the well within which potential contamination sources should be managed. Many methods have been developed to delineate such a wellhead protection area (WHPA). The integration of more information on the geologic and hydrogeologic characteristics of the study area increases the precision of any given WHPA delineation method. From a practical point of view, the WHPA delineation methods allowing the simplest and least expensive integration of the available information should be favored. This paper presents a comparative study in which nine different WHPA delineation methods were applied to a well and a spring in an unconfined granular aquifer and to a well in a confined highly fractured rock aquifer. These methods range from simple approaches to complex computer models. Hydrogeological mapping and numerical modeling with MODFLOW-MODPATH were used as reference methods to respectively compare the delineation of the zone of contribution and the zone of travel obtained from the various WHPA methods. Although applied to simple ground water flow systems, these methods provided a relatively wide range of results. To allow a realistic delineation of the WHPA in aquifers of variable geometry, a WHPA delineation method should ensure a water balance and include observed or calculated regional flow characteristics.  相似文献   

18.
This paper presents a Bayesian Monte Carlo method for evaluating the uncertainty in the delineation of well capture zones and its application to a wellfield in a heterogeneous, multiaquifer system. In the method presented, Bayes' rule is used to update prior distributions for the unknown parameters of the stochastic model for the hydraulic conductivity, and to calculate probability-based weights for parameter realizations using head residuals. These weights are then assigned to the corresponding capture zones obtained using forward particle tracking. Statistical analysis of the set of weighted protection zones results in a probability distribution for the capture zones. The suitability of the Bayesian stochastic method for a multilayered system is investigated, using the wellfield Het Rot at Nieuwrode, Belgium, located in a three-layered aquifer system, as an example. The hydraulic conductivity of the production aquifer is modeled as a spatially correlated random function with uncertain parameters. The aquitard and overlying unconfined aquifer are assigned random, homogeneous conductivities. The stochastic results are compared with deterministic capture zones obtained with a calibrated model for the area. The predictions of the stochastic approach are more conservative and indicate that parameter uncertainty should be taken into account in the delineation of well capture zones.  相似文献   

19.
The primary goals for most ground water capture systems (i.e., pump-and-treat systems) are that (1) all contaminants within zones of interest will eventually be captured and (2) the extraction and reinjection wells are best located and operated at optimal flow rates, creating hydraulically efficient flow systems. A new tool, MODular ALLocation (MODALL), is presented to aid in the design and assessment of capture systems. MODALL uses the MODFLOW-calculated cell-by-cell flow terms to evaluate internodal flow balances to determine the percentage of flow in each cell which has either originated from a given source(s) or flows to a specified sink(s). Output from MODALL can be easily displayed in isopleths of "capture fraction" (CF) to indicate the certainty or strength of capture in various areas. MODALL results are compared to the results from an analytical solution, a pathline analysis using MODPATH, and solute transport simulation with MT3DMS. A brief case study is also presented where MODALL is used to optimize an existing pump-and-treat system to more effectively and more efficiently contain a 5000-m long plume.  相似文献   

20.
Ground water quality networks for monitoring phreatic drinking water wellfields are generally established for two main purposes: (1) the short-term safeguarding of public water supply and (2) signaling and predicting future quality changes in the extracted ground water. Six monitoring configurations with different well locations and different screen depths and lengths were evaluated using a numerical model of the 3D ground water flow toward a partially penetrating pumping well in a phreatic aquifer. Travel times and breakthrough curves for observation and pumping wells were used to judge the effectiveness of different design configurations for three monitoring objectives: (1) early warning; (2) prediction of future quality changes; and (3) evaluation of protection measures inside a protection zone. Effectiveness was tested for scenarios with advective transport, first-order degradation, and linear sorption. It is shown that the location and especially the depth of the observation wells should be carefully chosen, taking into account the residence time from the surface to the observation well, the residual transit times to the extraction well, and the transformation and retardation rates. Shallow monitoring was most functional for a variety of objectives and conditions. The larger the degradation rates or retardation, the shallower should the monitoring be for effective early warning and prediction of future ground water quality. The general approach followed in the current study is applicable for many geohydrological situations, tuning specific monitoring objectives with residence times and residual transit times obtained from a site-specific ground water flow model.  相似文献   