首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The capture efficiency map: the capture zone under time-varying flow   总被引:3,自引:0,他引:3  
Festger AD  Walter GR 《Ground water》2002,40(6):619-628
The capture zone or contributing area of a ground water extraction well can be defined as that portion of the aquifer from which the well draws its water. Accurate delineation of capture zones is important in many ground water remediation applications and in the definition of wellhead protection areas. Their mathematical delineation is often simplified by using quasi-steady-state models based on time-weighted average pumping rates and background hydraulic gradients. We present a new semianalytic approach for the definition of capture zones under transient-flow conditions. We then use this approach to evaluate the effects of time variations in the direction of the background hydraulic gradient on capture. Results are presented in the form of capture efficiency maps (CEMs). Although the area contributing to a given well is found to generally expand relative to the steady-state average capture zone when the gradient direction varies, the zone of 100% capture may expand or contract depending on site-specific conditions. We illustrate our CEM approach by applying it to the design of a plume containment system.  相似文献   

2.
The U.S. Environmental Protection Agency has established several methods to delineate wellhead protection areas (WHPAs) around community wells in order to protect them from surface contamination sources. Delineating a WHPA often requires defining the capture zone for a well. Generally, analytical models or arbitrary setback zones have been used to define the capture zone in areas where little is known about the distribution of hydraulic head, hydraulic conductivity, or recharge. Numerical modeling, however, even in areas of sparse data, offers distinct advantages over the more simplified analytical models or arbitrary setback zones. The systematic approach discussed here calibrates a numerical flow model to regional topography and then applies a matrix of plausible recharge to hydraulic conductivity ratios ( R / K ) to investigate the impact on the size and shape of the capture zone. This approach does not attempt to determine the uncertainty of the model but instead yields several possible capture zones, the composite of which is likely to contain the actual capture zone. A WHPA based on this composite capture zone will protect ground water resources better than one based on any individual capture zone. An application of the method to three communities illustrates development of the R / K matrix and demonstrates that the method is particularly well suited for determining capture zones in alluvial aquifers.  相似文献   

3.
Steady flow to a well near a stream with a leaky bed   总被引:2,自引:0,他引:2  
Bakker M  Anderson EI 《Ground water》2003,41(6):833-840
We present an explicit analytic solution for steady, two-dimensional ground water flow to a well near a leaky streambed that penetrates the aquifer partially. Leakage from the stream is approximated as occurring along the centerline of the stream. The problem domain is infinite and pumping on one side of the stream induces flow on the other side. The solution includes the effects of uniform flow in the far field and a sloping hydraulic head in the stream. We use the solution to investigate the interaction between ground water and surface water in the stream, the effects of pumping on the opposite side of the stream, and the effects of the leaky streambed on the capture zone envelope of the well. We develop a relationship between parameters such that the pumping well will not capture water from the stream, or from the opposite side of the stream. When the discharge of the well is large enough to capture water from the stream, the shape of the capture zone envelope depends on flow conditions on the side of the stream opposite the well.  相似文献   

4.
Ceric A  Haitjema H 《Ground water》2005,43(3):408-412
As part of its Wellhead Protection Program, the U.S. EPA mandates the delineation of "time-of-travel capture zones" as the basis for the definition of wellhead protection zones surrounding drinking water production wells. Depending on circumstances the capture zones may be determined using methods that range from simply drawing a circle around the well to sophisticated ground water flow and transport modeling. The simpler methods are attractive when faced with the delineation of hundreds or thousands of capture zones for small public drinking water supply wells. On the other hand, a circular capture zone may not be adequate in the presence of an ambient ground water flow regime. A dimensionless time-of-travel parameter T is used to determine when calculated fixed-radius capture zones can be used for drinking water production wells. The parameter incorporates aquifer properties, the magnitude of the ambient ground water flow field, and the travel time criterion for the time-of-travel capture zone. In the absence of interfering flow features, three different simple capture zones can be used depending on the value of T . A modified calculated fixed-radius capture zone proves protective when T < 0.1, while a more elongated capture zone must be used when T > 1. For values of T between 0.1 and 1, a circular capture zone can be used that is eccentric with respect to the well. Finally, calculating T allows for a quick assessment of the validity of circular capture zones without redoing the delineation with a computer model.  相似文献   

5.
Hu LT  Chen CX 《Ground water》2008,46(4):642-646
Concurrent existence of confined and unconfined zones of an aquifer can arise owing to ground water withdrawal by pumping. Using Girinskii's potential function, Chen (1974, 1983) developed an approximate analytical solution to analyze transient ground water flow to a pumping well in an aquifer that changes from an initially confined system to a system with both unconfined and confined regimes. This article presents the details of the Chen model and then compares it with the analytical model developed by Moench and Prickett (1972) for the same problem. Hypothetical pumping test examples in which the aquifer undergoes conversion from confined to water table conditions are solved by the two analytical models and also a numerical model based on MODFLOW. Comparison of the results suggests that the solutions of the Chen model give better results than the Moench and Prickett model except when the radial distance is very large or aquifer thickness is large compared with drawdown.  相似文献   

6.
Abstract

An analytical solution is developed to delineate the capture zone of a pumping well in an aquifer with a regional flow perpendicular to a stream, assuming a leaky layer between the stream and the aquifer. Three different scenarios are considered for different pumping rates. At low pumping rates, the capture zone boundary will be completely contained in the aquifer. At medium pumping rates, the tip of the capture zone boundary will intrude into the leaky layer. Under these two scenarios, all the pumped water is supplied from the regional groundwater flow in the aquifer. At high pumping rates, however, the capture zone boundary intersects the stream and pumped water is supplied from both the aquifer and the stream. The two critical pumping rates which separate these three scenarios, as well as the proportion of pumped water from the stream and the aquifer, are determined for different hydraulic settings.

Editor D. Koutsoyiannis; Associate editor A. Koussis

Citation Asadi-Aghbolaghi, M., Rakhshandehroo, G.R., and Kompani-Zare, M., 2013. An analytical approach to capture zone delineation for a well near a stream with a leaky layer. Hydrological Sciences Journal, 58 (8), 1813–1823.  相似文献   

7.
We consider the effect of randomly heterogeneous hydraulic conductivity on the spatial location of time-related capture zones (isochrones) for a non-reactive tracer in the steady-state radial flow field due to a pumping well in a confined aquifer. A Monte Carlo (MC) procedure is used in conjunction with FFT-based spectral methods. The log hydraulic conductivity field is assumed to be Gaussian and stationary, with isotropic exponential correlation. Various degrees of domain heterogeneity are considered and stability and accuracy of the MC procedure is examined. The location of an isochrone becomes uncertain due to heterogeneity, and it is strongly influenced by hydraulic conductivity variance. The probability that a particle released at a point in the aquifer is pumped by the well within a given time is identified. We propose a new expression for the probabilistic spatial distribution of isochrones, which is formally similar to the analytical solution for a uniform medium and takes into account the effects of heterogeneity.  相似文献   

8.
A transient flow modeling analysis for potential public-supply wells on western Cape Cod, Massachusetts, demonstrates the difference between transient and steady-state recharge areas can have important implications for wellhead protection. An example of a single pumping well illustrates that commonly used steady-state time-related capture areas do not represent the recharge area and travel times of water being pumped from the well until sufficient time has elapsed for steady-state flow conditions to be established. Until that time, transient recharge areas are needed to account for the portion of water discharging from the well that entered the aquifer before pumping started. An example of two pumping wells demonstrates the same area at the water table cannot supply water to more than one well under steady-state flow conditions. Transient recharge areas to multiple wells can overlap, however, until steady-state flow conditions are established. The same area can, therefore, be a source of water to more than one well during early pumping times, and the water pumped from a given well may derive from source areas, including contaminated areas, that do not lie within the well's steady-state recharge area.  相似文献   

9.
A new steady‐state analytical solution to the two‐dimensional radial‐flow equation was developed for drawdown (head) conditions in an aquifer with constant transmissivity, no‐flow conditions at the top and bottom, constant head conditions at a known radial distance, and a partially completed pumping well. The solution was evaluated for accuracy by comparison to numerical simulations using MODFLOW. The solution was then used to estimate the rise of the salt water‐fresh water interface (upconing) that occurs under a pumping well, and to calculate the critical pumping rate at which the interface becomes unstable, allowing salt water to enter the pumping well. The analysis of salt water‐fresh water interface rise assumed no significant effect on upconing by recharge; this assumption was tested and supported using results from a new steady‐state analytical solution developed for recharge under two‐dimensional radial‐flow conditions. The upconing analysis results were evaluated for accuracy by comparison to those from numerical simulations using SEAWAT for salt water‐fresh water interface positions under mild pumping conditions. The results from the equation were also compared with those of a published numerical sharp‐interface model applied to a case on Cape Cod, Massachusetts. This comparison indicates that estimating the interface rise and maximum allowable pumping rate using the analytical method will likely be less conservative than the maximum allowable pumping rate and maximum stable interface rise from a numerical sharp‐interface model.  相似文献   

10.
As part of an agricultural non-point-source study in the Conestoga River head waters area in Pennsylvania, different methods for collecting ground water samples from a fractured carbonate-rock aquifer were compared. Samples were collected from seven wells that had been cased to bedrock and drilled as open holes to the first significant water-bearing zone. All samples were analyzed for specific conductance, dissolved oxygen, and dissolved-nitrogen species. Water samples collected by a point sampler without pumping the well were compared to samples collected by a submersible pump and by a point sampler after pumping the well. Samples collected by using a point sampler, adjacent to major water-bearing zones in an open borehole without pumping the well, were not statistically different from samples collected from the pump discharge or from point samples collected adjacent to major water-bearing zones after pumping the well. Samples collected by using a point sampler without pumping the well at depths other than those adjacent to the water-bearing zones did not give the same results as the other methods, especially when the water samples were collected from within the well casings. It was concluded that, for the wells at this site, sampling adjacent to major water-bearing zones by using a point sampler without pumping the well provides samples that are as representative of aquifer conditions as samples collected from the pump discharge after reaching constant temperature and specific conductance, and by using a point sampler after pumping the well.  相似文献   

11.
Advective transport from a finite line contamination source to an extraction well with regional flow depends on interplay of radial and regional flows, a scheme commonly encountered in capture zone delineation. We have investigated travel-time distribution from a finite line contamination source and the associated breakthrough curves (BTCs) observed at an extraction well. The resulting travel-time distribution and BTCs depend on dimensionless source length, dimensionless pumping rate, and inclined angle of the source with respect to the regional flow, where the dimensionless terms are lumped parameters involving source length, pumping rate, distance between the source and the extraction well, aquifer thickness, and regional flow discharge. The observed concentration at the extraction well increases with time in a sub-linear manner. When the source orientation is perpendicular to the regional flow, the dimensionless first arrival time only depends on the dimensionless pumping rate whereas the dimensionless steady-state arrival time depends on both the dimensionless pumping rate and the dimensionless source length. The steady-state concentration at the extraction well is sensitive to the dimensionless source length and the inclined angle of the source with respect to the regional flow, but not sensitive to the dimensionless pumping rate. Two special cases where the extraction well is very close to the source and the regional flow can be negligible have also been discussed.  相似文献   

12.
Lu C  Chen Y  Luo J 《Ground water》2012,50(3):386-393
Prevention of sea water intrusion in coastal aquifers subject to groundwater withdrawal requires optimization of well pumping rates to maximize the water supply while avoiding sea water intrusion. Boundary conditions and the aquifer domain size have significant influences on simulating flow and concentration fields and estimating maximum pumping rates. In this study, an analytical solution is derived based on the potential-flow theory for evaluating maximum groundwater pumping rates in a domain with a constant hydraulic head landward boundary. An empirical correction factor, which was introduced by Pool and Carrera (2011) to account for mixing in the case with a constant recharge rate boundary condition, is found also applicable for the case with a constant hydraulic head boundary condition, and therefore greatly improves the usefulness of the sharp-interface analytical solution. Comparing with the solution for a constant recharge rate boundary, we find that a constant hydraulic head boundary often yields larger estimations of the maximum pumping rate and when the domain size is five times greater than the distance between the well and the coastline, the effect of setting different landward boundary conditions becomes insignificant with a relative difference between two solutions less than 2.5%. These findings can serve as a preliminary guidance for conducting numerical simulations and designing tank-scale laboratory experiments for studying groundwater withdrawal problems in coastal aquifers with minimized boundary condition effects.  相似文献   

13.
A transient axisymmetric saturated-unsaturated numerical flow model was coupled with a particle tracking model to investigate the movement of contaminants when a shallow unconfined aquifer is pumped at a constant rate. The particle tracking model keeps track of locations and masses of solutes in the aquifer, and the time of capture by the well. At the end of each time-step the flow model solves the Richard's equation for the hydraulic head distribution from which elemental velocities are calculated. Solutes are then displaced for a period equivalent to the time-step using both the magnitude and direction of the elemental velocities. Numerical experiments were performed to investigate effluent concentrations in wells with screens of different length and in different positions relative to zones of stratified contamination. At early times of pumping the effluent concentrations were similar to the concentrations adjacent to the well screen, but at late times, the concentrations approached the vertically averaged concentration in the aquifer. Time to attain the vertically averaged concentration was determined by the well geometry, initial location of the contaminant plume in relation to the well screen, and hydraulic properties of the aquifer. The results are consistent with the hydraulics of flow to a pumping well and of particular importance, they demonstrate that short-term pump tests could give erroneous design concentrations for pump-and-treat systems. The model provides a means of quantifying arrival times and mixing ratios. It could therefore provide a useful means of designing production wells in aquifers with stratified contamination and more efficient recovery systems for aquifer remediation.  相似文献   

14.
This paper presents a new semi‐analytical solution for a slug test in a well partially penetrating a confined aquifer, accounting for the skin effect. This solution is developed based on the solution for a constant‐flux pumping test and a formula given by Peres and co‐workers in 1989. The solution agrees with that of Cooper and co‐workers and the KGS model when the well is fully penetrating. The present solution can be applied to simulate the temporal and spatial head distributions in both the skin and formation zones. It can also be used to demonstrate the influences of skin type or skin thickness on the well water level and to estimate the hydraulic parameters of the skin and formation zones using a least‐squares approach. The results of this study indicate that the determination of hydraulic conductivity using a conventional slug‐test data analysis that neglects the presence of a skin zone will give an incorrect result if the aquifer has a skin zone. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

15.
More than 200,000 gallons of automatic transmission fluid (ATF) leaked from an underground storage tank system and contaminated an area of about 64,000 ft2 of a soil and ground water system. A pumping strategy for improved drainage and recovery of free oil was developed, tested in a laboratory model aquifer, and implemented and evaluated at the field site. This pumping strategy differs from conventional approaches in two important ways: (1) The oil recovery rate is carefully controlled to maximize the pumping rate while maintaining continuity between the oil layer in the soil and the recovery well, to avoid isolation of the oil in the subsurface; and (2) The rate of ground water pumping is controlled to maintain the depressed oil/water interface at its prepumped position. This approach prevents further spread of oil into the ground water, prevents reduction in the volume of recoverable oil due to residual retention, and maintains a gradient for oil flow toward the recovery well. In a model aquifer study, nearly 100 percent of the recoverable volume of ATF was pumped from the system, and about 56,000 gallons of the ATF has been recovered from the field site.  相似文献   

16.
Volatile organic compounds delected in ground water from wells at Test Area North (TAN) at the Idaho National Engineering Laboratory (INEL) prompted RCRA facility investigations in 1989 and 1990 and a CERCLA-driven RI/FS in 1992. In order to address ground water treatment feasibility, one of the main objectives, of the 1992 remedial investigation was to determine the vertical extent of ground water contamination, where the principle contaminant, of concern is trichloroethylene (TCE). It was hypothesized that a sedimentary interbed at depth in the fractured basalt aquifer could be inhibiting vertical migration of contaminants to lower aquifers. Due to the high cost of drilling and installation of ground water monitoring wells at this facility (greater than $100,000 per well), a real time method was proposed for obtaining and analyzing ground water samples during drilling to allow accurate placement of well screens in zones of predicted VOC contamination. This method utilized an inflatable pump packer pressure transducer system interfaced with a datalogger and PC at land surface. This arrangement allowed for real lime monitoring of hydraulic head above and below the packer to detect leakage around the packer during pumping and enabled collection of head data during pumping for estimating hydrologic properties. Analytical results were obtained in about an hour from an on-site mobile laboratory equipped with a gas chromalograplvmass spectrometer (GC/MS). With the hydrologic and analytical results in hand, a decision was made to either complete the well or continue drilling to the next test zone. In almost every case, analytical results of ground water samples taken from the newly installed wells closely replicated the water quality of ground water samples obtained through the pump packer system.  相似文献   

17.
Fault zones are an important control on fluid flow, affecting groundwater supply, contaminant migration, and carbon storage. However, most models of fault seal do not consider fault zone cementation, despite the recognition that it is common and can dramatically reduce permeability. In order to study the field-scale hydrogeologic effects of fault zone cementation, we conducted a series of aquifer pumping tests in wells installed within tens of meters of the variably cemented Loma Blanca Fault, a normal fault in the Rio Grande Rift. In the southern half of the study area, the fault zone is cemented by calcite; the cemented zone is 2-8 m wide. In the center of the study area, the cemented fault zone is truncated at a buttress unconformity that laterally separates hydrostratigraphic units with a ∼40X difference in permeability. The fault zone north of the unconformity is not cemented. Constant rate pumping tests indicate that where the fault is cemented, it is a barrier to groundwater flow. This is an important demonstration that a fault with no clay in its core and similar sediment on both sides can be a barrier to groundwater flow by virtue of its cementation; most conceptual models for the hydrogeology of faults would predict that it would not be a barrier to groundwater flow. Additionally, the lateral permeability heterogeneity across the unconformity imposes another important control on the local flow field. This permeability discontinuity acts as either a no-flow boundary or a constant head boundary, depending on the location of pumping.  相似文献   

18.
Regular aquifer storage recovery, ASR, is often not feasible for small‐scale storage in brackish or saline aquifers because fresh water floats to the top of the aquifer where it is unrecoverable. Flow barriers that partially penetrate a brackish or saline aquifer prevent a stored volume of fresh water from expanding sideways, thus increasing the recovery efficiency. In this paper, the groundwater flow and mixing is studied during injection, storage, and recovery of fresh water in a brackish or saline aquifer in a flow‐tank experiment and by numerical modeling to investigate the effect of density difference, hydraulic conductivity, pumping rate, cyclic operation, and flow barrier settings. Two injection and recovery methods are investigated: constant flux and constant head. Fresh water recovery rates on the order of 65% in the first cycle climbing to as much as 90% in the following cycles were achievable for the studied configurations with constant flux whereas the recovery efficiency was somewhat lower for constant head. The spatial variation in flow velocity over the width of the storage zone influences the recovery efficiency, because it induces leakage of fresh water underneath the barriers during injection and upconing of salt water during recovery.  相似文献   

19.
Ground water/surface water interaction in a fractured rock aquifer   总被引:1,自引:0,他引:1  
In a recent field study of ground water/surface water interaction between a bedrock stream and an underlying fractured rock aquifer, it was determined that the majority of ground water discharge occurred through sparsely located vertical fractures. In this paper, the dominant mechanisms governing ground water/surface water exchange in such an environment are investigated using a numerical model. The study was conducted using several conceptual models based on the field study results. Although the field results provided the motivation for the modeling study, it was not intended to match modeling and field results directly. In addition, the extent of capture zones for discharging or recharging fractures was explored. The results of this study are intended to provide a better understanding of contaminant migration in the vicinity of bedrock streams. Based on the numerical results, the rate of ground water discharge (or recharge) was found to depend on the aperture size of the discharging feature, and on the distribution of hydraulic head with depth within the fracture network. It was determined that the extent of both the capture zone and reverse capture zone for an individual fracture can be extremely large, and will be determined by the height of the stream stage, the fracture apertures of the network, and the hydraulic-head distribution within the network. Because both the stream stage and the hydraulic-head distribution are transient, the size of the capture zone and/or the reverse capture zone for an individual fracture may change significantly over time. As a result, the migration path for contaminants within the fracture network and between the surface and subsurface will also vary significantly with time.  相似文献   

20.
The calculation of ground water transit times is one important factor in ground water protection. In this paper, we present an analytical solution for the transit time for a Dupuit-type flow system applicable to saturated flow through a horizontal leaky aquifer discharging to a downgradient fixed-head boundary under steady-state conditions. We investigate the influence of leakage when comparing the resulting travel times of our model based on head-dependent leakage with the commonly used model with no leakage and a simplified model with constant leakage. The results show significant differences in the position of the water divide and transit time, suggesting that leakage cannot be ignored.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号